This Sources Sought opportunity from Department Of Defense was posted on May 2, 2006. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Z -- Replace Failed SCADA System

Closed
FA8601-06-050011Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

88 CONS/PKC, 1940 Allbrook Dr, Ste 3, Wright-Patterson AFB, OH 45433-5309. 45433-5309, OH

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA5066 Hq Afmc/pk
Contacts1 person available
OfficeWRIGHT PATTERSON AFB, OH, 45433-5066, USA
Office AddressWRIGHT PATTERSON AFB, OH, 45433-5066, USA
Contacts

Full Description

Show more
The Air Force is seeking sources for a potential 100 percent set-aside for HUBZone, or Service Disabled Veteran Owned Small Business (SDVOSB) concerns. IF ADEQUATE RESPONSES ARE NOT RECEIVED, THE ACQUISITION MAY BE SOLICITED ON AN UNRESTRICTED BASIS. This is a sources sought for planning purposes only. Title/Description: Replace Failed SCADA System, Project 050011. This project replaces the remote monitoring and control system, Supervisory Control and Data Acquisition (SCADA), for the primary electrical power distribution system located at WPAFB. This system consists of power sensors, relays, remote terminal units, and the interconnecting control conductors in 9 substations located throughout the base. It also consists of a front-end computer system located in one central facility along with other remote monitoring sites. The estimated magnitude of the project is between $500,000 and $1,000,000. Special Requirements/Concerns: The SCADA system monitors and controls the primary electrical distribution system from all of WPAFB. The contract requires the installation of highly specialized hardware controlled by custom written computer code. It requires the correct installation of thousands of control conductors, hundreds of relays, and hundreds of sensors. Prime contractors who are HUBZone and/or SDVOSB and who intend to submit a bid for this solicitation MUST submit the following by 2:00 p.m. (local Dayton time) on 08 May 2006: (1) a positive statement of your intention to submit a bid for this solicitation as a Prime Contractor; (2) date of HUBZone and/or SDVOSB certification; (3) listing of experience in work similar in type and scope that you identified to include contract numbers, project titles, dollar amounts, and points of contact with their current phone numbers; (4) evidence of capability to be bonded for bid, performance and payment bonds; and (5) if you are a HUBZone considering a joint venture, you will need to provide proof that this consideration has been forwarded to the cognizant SBA office for approval. Firms interested should provide the above documentation, e-mail and faxed responses will be accepted. All of the above must be submitted in sufficient detail for a decision to be made on the availability of interested HUBZone or SDVOSB concerns. Responses shall be limited to 5 pages. Failure to submit all information requested would result in a contractor being considered 'not interested' in this requirement. The mailing address for responses is 88 CONS/PKC, 1940 Allbrook Dr, Ste 3, Wright-Patterson AFB, OH 45433-5309.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS