Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Veterans Affairs was posted on April 7, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Z1DA--528A6-19-605 REPLACE ROOF BUILDING 76

Closed
36C24223B0019Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238160
New
Inland Empire Job Corps-Request for Quote Roof Design & Build
Solicitation # inland-empire-job-corps-request-quote-roof-design-build
Management & Training Corporation is seeking quotes for a fixed-price design-build subcontract to construct an over-build enclosure for the lower roof of Building G at the Inland Empire Job Corps Center in San Bernardino, California. The project involves designing and installing a roof covering approximately 800 gross square feet, featuring a 3% sloped roof with a single ply, EPDM 60 mil roofing system over wood or metal decking. The scope includes structural framing that extends existing bearing walls or utilizes a new post-beam system, the installation of three LED strip light fixtures with one emergency backup, and strict adherence to OSHA safety standards and the Architectural Barriers Act Accessibility Standard of 2007. The total period of performance is 240 days, with a requirement to complete the work within 100 consecutive business days following the Notice to Proceed. Bids are due by November 2, 2026, and will be evaluated based on overall best value. This is a small business set-aside opportunity open to various SBA certifications. For bids equal to or greater than $25,000, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from a surety with at least an A- rating. Bidders must conduct a physical site visit and sign an attendance roster to be eligible. The project is subject to Construction Wage Rate Requirements, necessitating compliance with California prevailing wages and the submission of weekly certified payroll reports. Additionally, all inspections and testing must be conducted by an independent, third-party agency registered in California. Required insurance minimums include 1 million dollars per occurrence for general liability, 1 million dollars for auto, and 500,000 dollars for workers compensation.
Inland Empire Job Corps

POSTED

about 3 hours ago

DEADLINE

in 5 days
NAICS: 238160
New
SLED
INDEX ROOF FLUID APPLIED ROOF
Solicitation # 27-350SOS-PHYSE-B-54721
The Illinois Secretary of State is soliciting bids for the installation of a new fluid-applied roof system on the Index Building located at 111 E. Monroe St, Springfield, IL. The project requires the application of a white, cold-applied, single-component silicone elastomer membrane designed for permanent weather and sunlight exposure. Key deliverables include the construction of a 100 square foot mock-up, the performance of a 72-hour flood test to ensure water resistance, and the provision of a 20-year manufacturer full labor and material warranty. The award will be granted to the responsive and responsible bidder who submits the lowest price. Bidders must submit all proposals electronically via BidBuy by November 19, 2026, and must provide a 10% bid bond. The contract requires adherence to strict material storage and delivery standards, including the use of original manufacturer containers and storage in weather-protected environments. Compliance with the State Prompt Payment Act, prevailing wage laws, and the Illinois Department of Human Rights Act is mandatory. Additionally, the total contract term, including all renewals and extensions, cannot exceed ten years. Vendors must provide a Certificate of Insurance naming the State as an additionally insured party and are responsible for all safety barricades and traffic signage during the project.
PHYSERV350 - Physical Services

POSTED

about 13 hours ago

DEADLINE

in 21 days
NAICS: 238160
New
SLED
Gatesville ISD Intermediate Campus Roof Repair
Solicitation # RFP2026-1030
Gatesville Independent School District is soliciting sealed proposals under RFP 2026-1030 for comprehensive roof repairs at the Intermediate campus, with an expanded scope via addendum to include a portion of the High School campus facility. The project requires a qualified contractor to provide all labor, supervision, equipment, and materials for a commercial roofing layover. Key technical specifications include the removal of existing gravel, installation of 2.2 inch ISO board for the main area and 1 inch ISO board for the addendum area, and the application of 60mil GAF-TPO or an equivalent system. The scope also encompasses the installation of ten GAF speedtite drains with 4 inch piping, tapered ISO boards at drains, steel deck system patching for caved-in areas, and the installation of proper flashing and pipe boots according to manufacturer specifications. The contract will be awarded based on a competitive solicitation process rather than low price alone, considering factors outlined in the Texas Education Code. Successful bidders must provide a five-year workmanship warranty, general liability insurance, and a standard manufacturer warranty. Proposers must submit a complete packet including mandatory certifications such as the SB 9 Criminal History Record, House Bill 89 Verification, and Senate Bill 252 Certification. All proposals must be submitted in sealed envelopes by October 30, 2026, at 2:30 p.m., with the final award scheduled for November 16, 2026. Bids must remain firm for 60 days following the award date.
GATESVILLE ISD

POSTED

about 17 hours ago

DEADLINE

in 1 day

General Info

NAICS

238160 - Roofing Contractors

Place of Performance

NY

Set-Aside

NONE

Documents

7

36C24223B0019 Amendment 0001 - Replace Roof Building 76

DOCX, High priority: read this firstamendment
High

36C24223B0019 - Replace Roof Building 76 at the Bath VA

DOCX, High priority: read this firstifb
High

528A6-19-605 Replace Roof Building 76 - Drawings

PDF, High priority: read this firstspecifications
High

528A6-19-605 Replace Roof Building 76 Specifications

PDF, High priority: read this firstspecifications
High

528A6-19-605 Replace Roof Building 76 - Specifications

PDF, High priority: read this firstspecifications
High

36C24223B0019 Pre-Bid Conference Attendees - Replace Roof Building 76

PDF, Low priorityindustry-day
Low

36C24223B0019 - Replace Roof Building 76 Site Visit Agenda

DOCX, Low priorityindustry-day
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseClosed
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Notice updated

Response deadline changed from Apr 12, 2023 to Apr 13, 2023. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Devan BertchContract Specialist

Full Description

Show more
RFI SHEET Solicitation # 36C24223B0019 REPLACE ROOF BUILDING 76 - Bath VA Medical Center RFI # 1 Question - In the bid documents, it says that the VA will only choose a contractor who is certified for asbestos removal in NY. Will the VA allow us to sub the asbestos removal OR can they change the language so that the contractor has time to get certified before the notice to proceed? Answer A new specs document has been uploaded that has an amended Section 1.2 - General Intention - A. RFI # 2 Question Will plywood need to be installed as a substrate over the existing tongue and groove deck? Answer - Tongue and groove decking is an acceptable substrate and there is no warranty requirement for the installation of plywood over the existing T&G RFI # 3 Question - Is there current Sheathing on the building? Answer Yes, the existing sheathing is 1x6 T&G (see attached photo on last page). Question - Are there security fence areas? Answer - No Question - Scaffolding Areas for stair towers Answer - Limited Question - Laydown area(s) for dumpsters, forklift, job trailer, material trailer, parking, and additional materials Answer - The area will away from the immediate construction site. There isn t much room around the main hospital building. Question - Are there other projects going on at the building and adjacent areas? Answer - Yes. There will be 3 projects at this building. Question - Where can we hook up power to the job trailer from the power source? Answer - There is power available near the designated job trailer site. Question - Are there roof access areas from inside the building? Answer Yes, there is an existing roof access hatch located in the elevator penthouse. Question - Patient and staff access points Answer All four sides of the building. Question - Could we have weekend work authorization (bring up weather limitations due to the time of the project)? Answer - No. Normal work hours only. Question - Plan for slate removed (VA retains or do we need to dispose of it) Answer The removed existing slate shall be disposed of by the contractor. RFI # 4 Is the IMPS and IMPN new panels? Are they provided by us? Answer NEW, PROVIDED BY CONTRACTOR. SEE RESPONSE IN RFI#5, DRAWINGS AND SPECS FOR ADDITIONAL INFORMATION. Is the measurements on the heat trace just the roof or is it the length of the heat trace including the zig zag? Answer LENGTHS INDICATED ARE THE LENGTH OF THE SPECIFICED DESIGN MAKE HEAT TRACE THAT IS ON THE ROOF, FROM THE HOMERUN POWER WIRING JUNTION TO THE END OF THE RUN. RFI # 5 Contractor is inquiring to get information on the electric panels (IMPS - IMPN) that will be installed on the 7th floor based on the drawing EP-102. Need size of panel, qty of breakers. This is not covered on dwgs or in specs. Answer IMPS: 480/277V; 225A MCB; 30 CKT. PROVIDE (12) ACTIVE SINGLE POLE 30A BREAKERS AND (8) SPARE. (10) SPACE. IMPN: 480/277V; 225A MCB; 30 CKT. PROVIDE (7) ACTIVE SINGLE POLE 30A BREAKERS AND (13) SPARE. (10) SPACE. There is a discrepancy in the IM control panels. This may vary between vendors but they are saying the IMP requires a single pole 277v-30a breakers - not dbl pole 20a. Answer ALL BREAKERS SHALL BE SINGLE POLE 30A 277V. RFI #3 3.) Photo

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS