This contract amendment updates solicitation 36C24726R0039 to provide additional clarification regarding the existing fire alarm system and extends the proposal submission deadline to May 29, 2026, at 1:00 PM CDT. The solicitation is for the Correct FCA Assessment Findings on Failing Plumbing Conditions at Building 1 under VA contract number VA-26-00027345, with the North American Industry Classification System code 236220 indicating a focus on commercial and institutional building construction. The procuring agency is the Department of Veterans Affairs, specifically the 247-NETWORK Contract Office 7 in Augusta, Georgia, with Pamela R Moffitt listed as the primary Contract Specialist. The requirement centers on implementing a comprehensive Construction Quality Control Plan for a design-build project involving plumbing system upgrades, including removal of dead leg piping, installation of chlorination injection stations, water heater modifications, recirculation pump replacements, chiller and heat exchanger installations, piping insulation, and a continuous monitoring system. All work must adhere to stringent standards including NFPA 70, NFPA 99, ASTM specifications, AWS welding codes, ASME BPVC, and VA-specific guidance such as VA H-18-8-2013 and PG-18-10-2024. The evaluation process follows a Lowest Price Technically Acceptable approach, with technical acceptability serving as the primary gatekeeper—any proposal deemed unacceptable is eliminated regardless of price. Price proposals must be reasonable and free of materially unbalanced line items, as such imbalances may result in rejection. Past performance is evaluated but not weighted, with a neutral rating assigned if no relevant experience is demonstrated. The contract includes numerous mandatory clauses related to ethics, anti-kickback, whistleblower rights, and cybersecurity compliance, including deviations in FAR 52.216-1, 52.222-5, and 52.240-90. Special requirements mandate strict site security protocols, including vehicle searches, badge requirements, prohibition of weapons and alcohol, and controlled work hours. Key personnel must include a certified Safety and Health Manager, a qualified CQC System Manager with an alternate, and OSHA-trained staff, with training records due before the preconstruction conference. Packaging and marking requirements specify moisture protection for lumber and plywood, 152 mm elevation above grade, engraving standards for
General Info
Contract Value
$16,349,180Place of Performance
GA, USASet-Aside
Award Issued Date
Timeline
Organization & Contact Information
Full Description
Project: 619-23-105 Correct FCA Findings on Failing Plumbing Conditions for Building 1
Work Location: Central Alabama Veterans Health Care System at 215 Perry Hill Road Montgomery, AL, 36083
Estimated/Target Completion Period: 1095 days after issuance of Notice to Proceed
Construction Magnitude: Between $10,000,000 and $20,000,000
NAICS: 236220
Small Business Standard: $45 Million
Set-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB)
Contract Type: Firm-Fixed-Price (FFP) Construction Contact
Site Visits will not be arranged during this phase.
Submission Criteria/Requirements: Solicitation 36C24726R0039, (including any/all relevant documents, specifications, and drawings), will be posted on or about April 7, 2026, to https://sam.gov/ under Contract Opportunities. Any amendments to the solicitation will be posted solely to this website. It will be the responsibility of the offeror to verify the number of amendments issued. This requirement will be procured utilizing the Lowest Price Technically Acceptable (LPTA).
The anticipated award date of the proposed Construction Contract is on or before September 30, 2025.
This acquisition is a 100% Set Aside for Certified Service-Disabled Veteran-Owned Small Businesses (SDVOSBs).
Prospective Contractors are cautioned that a proposal submitted in response to this solicitation must meet the criteria identified in VAAR Clause 852.219-73, VA Notice of Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses (JAN 2023) (DEVIATION).
Prospective Contractors must comply with VAAR Clause 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction (JAN 2023) (DEVIATION). In the case of a contract for Specialty trade construction contractors, the contractor will not pay more than 85% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73. Any work that a similarly situated subcontractor further subcontracts will count towards the 85% subcontract amount that cannot be exceeded. Cost of materials is excluded and not considered to be subcontracted.
For an SDVOSB to be considered as a prospective contractor, the firm must be certified and listed in the SBA certification database (veterans.certify.sba.gov/) and registered in the System for Award Management (SAM) database (sam.gov) at time of submission of their qualification. A joint venture may be considered eligible as an SDVOSB if the joint venture complies with the requirements in 13 CFR 128.402 and the managing joint venture partner makes the representations under 852.219-73(c). A joint venture agrees that, in the performance of the contract, the applicable percentage specified in paragraph 852.219-73(d) of the clause will be performed by the aggregate of the joint venture participants. Failure of a prospective SDVOSB to meet these certification requirements by the SBA shall result in elimination from consideration. The firm must also report to VETS-4212 Federal Contractor Reporting in accordance with FAR 52.222-37, Employment Reports on Veterans at dol.gov/agencies/vets/programs/vets4212.
PROJECT INFORMATION/STATEMENT OF TASK: This project is to remove all dead leg piping sections. Re-apply insulation to all segments of HW piping where insulation is found to be missing. Install one chlorination injection station per floor. Increase temperature in water heaters to 140 F and where no existing mixing valve exists on the water heater, install a mixing valve to prevent scalding. Extend DHWR piping to within 6 feet of all fixtures and install small mixing valves at each sink/lavatory to allow increased HW supply temperature in piping to sink/lavatory. Replace DHW recirculation pumps to accommodate a larger flow rate. Install chiller (either air-cooled or include cooling tower and condenser water system), heat exchanger, chilled water pumps to chill all incoming domestic water down to below 68 F. Insulate all existing and new CW piping associated with new chilled conditions. Install insulated CW recirculation (DCWR) piping loop parallel to existing CW piping throughout the entire building. Install a continuous-monitoring system on incoming domestic water to monitor pH, chlorine levels, and temperature. The Project 2nd Floor and the patient areas on the 3rd floor at the Central Alabama Veterans Health Care System at 215 Perry Hill Road Montgomery, AL, 36083
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Veterans Affairs → 247-NETWORK Contract Office 7 (36C247)
Same awarding agency
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS