Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Veterans Affairs was posted on August 12, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Z2DZ--Refeed Electrical from Generator Room to ATS# 3

Closed
36C25925Q0638Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency (IEUA) is soliciting proposals under RFP-VC-26-010 for professional transformer oil testing services to enhance the reliability, safety, and maintainability of its transformers. The scope of work is divided into three primary areas: conducting visual and infrared thermographic inspections on energized transformers under typical load, installing standardized external oil sampling devices to improve safety and access, and performing comprehensive oil testing analysis. Additionally, the contractor is responsible for evaluating nitrogen blanket systems to ensure positive pressure and providing on-site training for up to 20 agency staff members on inspection tools and defect identification. All work must adhere to strict industry standards, including ASNT Level 1 certification for thermography, ASTM D923 for oil sampling, and NFPA 70E safety protocols. The agency intends to make a single award to the most capable offeror based on a cost-effective and time-efficient proposal. Key evaluation criteria include a proven track record of at least two similar projects within the last five years, the proposed staffing plan, personnel availability, and the fee structure. Proposals must be submitted electronically via PlanetBids by December 23, 2026, and must include a detailed project approach, company profile, and required certifications such as a Non-Collusion Statement and Workers' Compensation Certificate. The resulting contract will utilize fixed pricing with a not-to-exceed total value and may include one-year extension options at the agency's discretion. Payment will be processed electronically via ACH within 30 days of invoice approval by the Project Manager.
Inland Empire Utilities Agency

POSTED

about 8 hours ago

DEADLINE

in 2 months
NAICS: 238210
New
Purified Water Replenishment San Jacinto Valley Advanced Water Purification Facility
Solicitation # purified-water-replenishment-san-jacinto-valley-advanced-water-purification-facility-2
Axia Electric LLC is soliciting bids from SBE/DBE certified firms for the Purified Water Replenishment San Jacinto Valley Advanced Water Purification Facility and Brine Ponds project in California for the Eastern Municipal Water District. The requested scopes of work include low voltage systems, fiber optics, and the supply of electrical materials. Interested subcontractors must submit their price quotes by 2:00 PM on November 18th, with a final bid deadline of November 19th, 2026. Bidders are encouraged to provide information regarding any lower-tier SBE/DBE participation to be considered during the evaluation process. Qualified bidders must be registered to perform public work pursuant to Labor Code Section 1725.5 and must adhere to the AGC Master Labor Agreements. Awardees will be bound by the prime contract terms and Axia's Standard Long Form Subcontract or Purchase Order. Minimum insurance requirements include 1 million dollars for Auto Liability and Workers Compensation, 5 million dollars for Excess Liability, and General Liability coverage of 1 million dollars per occurrence, 2 million dollars aggregate, and 2 million dollars for completed operations. Primary points of contact for the solicitation are Ryan Falk for estimating and Amy Roller for contract documents.
Axia Electric

POSTED

about 8 hours ago

DEADLINE

in 28 days
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management and Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves a qualified electrical contractor inspecting, testing, repairing, and certifying emergency lighting systems to ensure compliance with NFPA 101 (2024 Edition) and NFPA 70 standards. Key deliverables include a full inventory of fixtures, functional testing via simulated power outages, the application of durable tracking labels to each fixture, integration of maintenance requirements into the facility's Computerized Maintenance Management System, and the provision of disposal certificates for hazardous materials. The estimated contract value ranges between $25,000 and $100,000. Bids are due by December 1, 2026, and must be submitted via email with a detailed cost breakout and the official MTC Bid for Lump Sum Contract form. A mandatory physical site visit is required prior to bid submission. For bids equal to or greater than $25,000, contractors must provide a bid bond guarantee of 20% of the base bid, as well as performance and payment bonds from a surety company with at least an A- rating. The award will be based on overall best value. This opportunity is set aside for small businesses, including certified VOSB, SDVOSB, WOSB, and HUBZone entities. The contract is subject to the Davis-Bacon Act, Federal Contractor Minimum Wage requirements, and FAR standards regarding work hours, safety, and the Buy American Act.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 8 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

This contract solicits electrical refeeding work from the generator room to ATS #3 at a Veterans Affairs facility, under solicitation number 36C25925Q0638. The scope addresses critical backup power infrastructure affecting key hospital functions, including MRI machines and emergency rooms, necessitating rigorous scheduling and coordination to ensure patient care is not disrupted. Awarded contractors must provide a detailed schedule outlining required access to the emergency rooms, and all critical outages for ATS-3 and MRIs are strictly limited to a maximum of four hours, with proper coordination and notification to minimize impact. Construction is to take place in active hospital environments, with access to emergency rooms arranged through controlled procedures, including COR badge access and adherence to an Infection Control Risk Assessment (ICRA) plan. Work is preferred during standard business hours (7:00am to 3:30pm) due to the 24/7 operation of the emergency department. Electrical installation must use 4/0 conductors in either a 2 1/2" or 3" conduit, running with existing conduits for permanent installations, and the new feeder must be fully in place before any demolition of the existing feeder to maintain uninterrupted critical services. Contractors are responsible for the coordination of shutdowns, adherence to hospital protocols, and ensuring barrier placement and safety during any simultaneous closures or activities in sensitive areas. The contract's duration is closely coordinated, and the response deadline is August 18, 2025, with further points of contact and supporting documentation provided via the SAM.gov portal.

General Info

Electrical refeeding from generator to ATS #3, strict outage limits, hospital safety coordination required.

Contract Value

$50,104.5

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

CO

Set-Aside

NONE

Award Issued Date

Documents

9

36C25925Q0638 Amendment 0001

DOCX, High priority: read this first2 pages · amendment
High

36C25925Q0638 Amendment 0002 - Refeed Electrical from Generator Room to ATS #3

DOCX, High priority: read this first14 pages · amendment
High

36C25925Q0638 - SF 1442 Solicitation for Refeed Electrical Generator Room to ATS

DOCX, High priority: read this first44 pages · ifb
High

Pre-Bid Meeting: Refeed Electrical from Generator Room to ATS #3

DOCX, High priority: read this first1 page · presolicitation
High

Self-Performed/Subcontracted Work Worksheet

DOCX, High priority: read this first2 pages · sow
High

VA Notice of Limitations on Subcontracting - Certificate of Compliance (852.219-75)

DOCX, High priority: read this first2 pages · certificate-of-compliance
High

VHA ICRA Template for Construction, Renovation and Maintenance

PDF, High priority: read this first9 pages · sow
High

36C25925Q0638 Pre-Construction Site Visit Attendance

PDF, Low prioritysite-visit-sign-in
Low

ATS #3 - Generator Room Panel Box

PDF, Low priority3 pages · other
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseClosed
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 19 (36C259)
Contacts1 person available
OfficeGreenwood Village, CO, 80111, USA
Office AddressGreenwood Village, CO, 80111, USA
Contacts
Frances Basham (COContracting Specialist

Full Description

Show more
RFQ 36C25925Q0638 Refeed Electrical from Generator Room to ATS #3 Vendor Questions and VA answers in red CONTRACTOR Q&As #1 Question No. 1: How many days' notice do we need to provide to access the two ER rooms and pipe out of both? Answer No. 1: Please provide an overall schedule to include the days that you will need access to the rooms as a submittal prior to start of work Question No. 2: How long can each ER be shut down? And can both be shut down simultaneously, or will they need to be phased down? Answer No. 2: Please provide an overall schedule to include the days that you will need access to the rooms as a submittal prior to start of work Question No. 3: Is there a way to coordinate access to the 2 ER Rooms in the same day, shut down the ATS 3, which powers all or most of the hospitals MRI machines, and Panel EGR to tie it all in, in the same week and shut down ATS#3 and the panel feeding it, all in the same week? Answer No. 3: Part 1: both ER rooms would be able to be closed at the same time, in doing so a barrier would have to be placed at the entrances, as only one tile can be out at a time otherwise. Part 2: ATS-3 is critical and down time is limited to four hours in total, it can not be down for a week. Question No. 4: What are the hours we can work, without noise affecting patients with drilling through concrete walls? Answer No. 4: There is no best time to work. Patient occupancy fluctuates. COR work hours are 7:00am to 1530pm. Question No. 5: What are the busiest days for MRIS? Answer No. 5: It varies, as it supports our emergency patients as well as regularly scheduled patients, two weeks notice and coordination will ensure goal is met for outage. Question No. 6: How long can we shut MRIS down? Answer No. 6: No more than 4 hours. Provide schedule of work Question No. 7: Do we need to shut down the Panel EGP, which supplies ATS #3 and features a 225 amp breaker, in order to work on it, or can we work on it while it's live? Answer No. 7: Panel EGP is only energized when the generator is running, there will be no problem in shutting the main breaker off, located left of the panel in generator control gear, as long as electrical staff is made aware at the time, no notice would be required for this portion of the project. Question No. 8. Please confirm award contractor will have access to the emergency room during construction. Answer No. 8: Yes, the contractor will have access to the emergency room, however, the COR will have to badge the contractors in Question No. 9: Since construction will be performed in an active emergency room, will an ICRA plan be provided to all bidders? Answer No. 9: Yes an ICRA will be provided to all bidders Question No. 10: Can the VA specify conduit and wire size/type that needs to be installed? Answer No. 10: 4) 4/0s 1) #4 ground, in a 2 1/2' or 3 conduit, contractor s choice. Question No 11: Can an alternate route be considered? Outside above the canopy walkway possibly? This would keep us from having to go through ER areas. Answer No. 11: Conduit needs to be ran with existing conduits, everything currently ran on the outside is for temporary equipment only, permanent utilities need to be physically secured and away from damage. Question No. 12: Does the new feeder need to be in place and ready to terminate before we can demo the old feeder? Or can we demo old feeder as we install new feeder? Answer No. 12: Yes, new feeder needs to be in place prior to demo of existing feeder, providing continuity of backup generator feed serving critical loads and patients. Question No. 13: Please confirm if we can do all of the install during normal working hours. Answer No. 13: Normal business hours would be best as this is an emergency room, which never shuts down.

More opportunities from Department Of Veterans Affairs → Network Contract Office 19 (36C259)

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS