Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 5 at 2:00 PM EDT

Register Free →

4 SEASONS HEATING AND COOLING 169 PINE CREEK ROAD LIVINGSTON MT 59047 USA

UEI: SLED_02A546D4A446FC42

4 SEASONS HEATING AND COOLING 169 PINE CREEK ROAD LIVINGSTON MT 59047 USA is a federal contractor, registered under UEI SLED_02A546D4A446FC42. It has been awarded $13,600 across 1 federal contract. Primary work spans Plumbing, Heating, and Air-Conditioning Contractors. Top awarding agencies include Lolo National Forest.

Contact Information

Registration and classification details

Registration

UEI Code

SLED_02A546D4A446FC42

Federal Contracting Overview

Award totals, agency breakdown, NAICS distribution, and geographic footprint.

Key Performance Metrics

Awards Count

0

All time

Active

0

Currently performing

Completed

0

Past period of performance

Total Awards

All time

Contracts

Prime · all time

Subcontracts

Sub · all time

Grants

Prime · all time

Subgrants

Sub · all time

Award Analytics & Distribution

Awards by Agency
Lolo National Forest$13.6K100%
Awards by NAICS
238220 - Plumbing, Heating, and Air-Conditioning Contractors$13.6K100%
Awards by Agency Over Time
Export
Awards by Place of Performance

Open opportunities in 4 SEASONS HEATING AND COOLING 169 PINE CREEK ROAD LIVINGSTON MT 59047 USA's top NAICS codes and agencies

NAICS: 238220
New
SLED
FIS-Access Controlled WorkThis contract pertains to mechanical, electrical, or piping work within the Federal Inspection Station, requiring strict compliance with Customs and Border Protection vetting procedures and secure access protocols. All work must be performed by personnel who have undergone and passed the necessary CBP background clearances and access authorizations, ensuring that all activities are conducted within highly controlled and sensitive federal environments. The work is classified as a subcontract under NAICS code 238220, indicating specialized trade contracting, and is governed by the stringent security and operational standards unique to federal inspection facilities. The solicitation is open for responses until September 1, 2026, and is managed by the Planning, Engineering and Construction agency under the Florida office. The exact location of performance is not specified, but all work must occur within the confines of the Federal Inspection Station, which implies potential constraints on scheduling, site access, and coordination with federal personnel. Contractors must be prepared to meet rigorous security and compliance requirements without exception, and only qualified firms with proven experience in federally secured environments should pursue this opportunity. No set-aside status has been designated, and the contract does not specify point of contact details or physical address, suggesting all communication and submissions will be handled through the designated online procurement portal.
Planning, Engineering and Construction

POSTED

about 13 hours ago

DEADLINE

in 30 days
View Details
NAICS: 238220
New
Federal
Plumbing Repairs, Phoenix Rearing Facility
Solicitation # 12639526Q0197
The Phoenix Rearing Facility Plumbing Repairs solicitation, identified by number 12639526Q0197, is a fixed-price construction contract issued by the U.S. Department of Agriculture through its Minneapolis office, with performance located at the 69,000-square-foot facility in Phoenix, Arizona. The facility supports the Sterile Insect Technique program aimed at controlling navel orange worm populations impacting U.S. agriculture. This procurement requires comprehensive plumbing system repairs and upgrades to address chronic issues including backed-up sinks and urinals in both men’s restrooms, recurring clogs in maintenance and utility drains, and persistent odors in the QC clean lab area. The work scope includes removal and replacement of waste piping and vents with associated concrete repairs, remodeling the south restroom and showers to meet ABA compliance standards, performing minor fixture replacements and finish patching in the north restroom, and engaging a government-approved third-party inspection agency to verify all systems. The contract is set aside entirely for small businesses with a NAICS code of 238220 and a size standard of $19 million, with the offeror required to submit a lump-sum price that reflects a realistic understanding of the work and consistent technical approach. The contract imposes strict compliance with federal regulations including the Buy American Act, Construction Wage Rate Requirements under the Davis-Bacon Act, and sustainable product standards, with all materials required to be delivered in unopened manufacturer packaging with intact labels conforming to NFPA 70, ANSI A137.1, and ASME A13.1. Performance must commence within 10 days of receiving the Notice to Proceed and is governed by an 180-day period of performance. The contractor is mandated to provide performance and payment bonds, submit a site-specific safety plan, designate key personnel including a superintendent, quality control officer, and safety officer, and maintain detailed quality records including hydrostatic and welding inspections. Progress payments are available monthly and must be supported by itemized requests, subcontractor payment listings, lien waivers, and certified documentation, with payments processed within 14 days of a proper submission. Award will go to the responsible small business offering the highest technical rating with a fair and reasonable price, with no trade-offs permitted between cost and technical merit. All work must align with the 2010 ADA Standards for Accessible Design, and the contractor must certify compliance with federal anti-discrimination laws and environmental requirements, while also adhering to whistleblower protections and prohibitions against
Mrpbs Minneapolis Mn

POSTED

about 13 hours ago

DEADLINE

in 8 days
View Details
NAICS: 238220
New
Federal
Fire suppression system installation
Solicitation # 12639526Q0210
A fire suppression system installation is required at Building 6418 on Moore Air Base in Edinburg, Texas, following a recent fire that exposed the absence of any fire protection in the structure, which was built in the early 1980s. The project is a turnkey effort requiring the full design, installation, permitting, and commissioning of a new automatic sprinkler system including underground and overhead piping, canopy protection, flex drops for sprinkler heads centered in ceiling tiles, and a riser room with an above-ground backflow preventer, PIV, tap, and testing certification. All work must comply with NFPA standards, State of Texas environmental regulations, and local ordinances, using only new and unused materials. The system must be designed to allow for future integration with a fire alarm panel, though no active monitoring is required at this time. The solicitation is a combined synopsis and request for quotations issued under FAR Part 12 as a commercial items acquisition, with a total small business set-aside under NAICS code 238220 and a size standard of $19 million. Offers must be submitted electronically by 12:00 p.m. CT on August 6, 2026, to james.g.roloff@usda.gov with the solicitation number included in the subject line. A site visit is scheduled for July 23, 2026, and attendees must register in advance and present a valid driver's license or state ID for facility access. Award will be made using the Lowest Price Technically Acceptable (LPTA) method under FAR 12.203, where only the lowest-priced offer will be evaluated for technical acceptability unless it fails to meet requirements, in which case the process continues sequentially down the price list. The quote must include a complete breakdown of all components making up the lump-sum price, and the government will conduct a price realism analysis to ensure the submission is realistic, reflects a clear understanding of requirements, and is consistent with the technical proposal. Submissions deemed unreasonably low or high may be rejected for incorporating excessive risk. Technical acceptability is rated as acceptable or unacceptable based on the offeror’s demonstrated ability to meet all requirements, including relevant experience with fire sprinkler systems of similar scope. Past performance will be evaluated as acceptable, neutral, or unacceptable, with no history resulting in a neutral rating. All contractors must be registered in SAM, provide payment and performance bonds under FAR 52.
Mrpbs Minneapolis Mn

POSTED

about 13 hours ago

DEADLINE

in 5 days
View Details