Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

WEST INTERIOR SERVICES, INC.

UEI: NFFBKH2Q9AC7

WEST INTERIOR SERVICES, INC. is a federal contractor, registered under UEI NFFBKH2Q9AC7. It has been awarded $12,395 in federal contracts. Primary work spans Reupholstery and Furniture Repair. Top awarding agencies include Department Of Veterans Affairs.

Contact Information

Registration and classification details

Registration

UEI Code

NFFBKH2Q9AC7

Federal Contracting Overview

Award totals, agency breakdown, NAICS distribution, and geographic footprint.

Key Performance Metrics

Awards Count

1

All time

Active

0

Currently performing

Completed

1

Past period of performance

Total Awards

All time

Contracts

Prime · all time

Subcontracts

Sub · all time

Grants

Prime · all time

Subgrants

Sub · all time

Award Analytics & Distribution

Awards by Agency
Awards by NAICS
Awards by Agency Over Time
Awards by Place of Performance

Compete with WEST INTERIOR SERVICES, INC.

Track the contractors you bid against, and the work they win

Award history, agency mix, and NAICS coverage for WEST INTERIOR SERVICES, INC.

AI-powered matching against your own capabilities and past performance

Teaming and subcontracting signals on every award

Automated alerts when a competitor wins in your market

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS

Open opportunities in WEST INTERIOR SERVICES, INC.'s top NAICS codes and agencies

NAICS: 561990
New
Federal
Intent to Sole Source Fire Suppression and Emergency Response Service
Solicitation # 36C26326Q0635_1
The Department of Veterans Affairs, Network Contracting Office 23, intends to award a sole source contract to the City of Minneapolis for fire suppression and emergency response services at the Veterans Affairs Medical Center in Minneapolis, Minnesota, including buildings at Fort Snelling. This action is being taken under the authority of FAR 6.103-1 and FAR 12.102(a), as the government has determined that only one responsible source can satisfy the agency requirements. The contractor is required to provide 24/7 contractor owned and contractor operated services, including responses to fire alarms, hazardous material spills, confined space rescues, and elevator entrapments. Key performance requirements include maintaining a minimum of four certified professional firefighters and two fire pumper apparatus with at least 1200 gpm capacity, ensuring a maximum response time of eight minutes to any location on the campus. The contractor must adhere to NFPA, IFC, OSHA, and State of Minnesota standards, maintain a minimum ISO rating of 3, and hold mutual aid agreements with at least two other municipal fire departments. Deliverables include annual building inspections, a phase-in plan due within ten days of award, and a confined space rescue plan due within fourteen days of the notice of award. Interested parties wishing to challenge the sole source determination must submit a capabilities statement by October 23, 2026.
Department Of Veterans Affairs

POSTED

about 21 hours ago

DEADLINE

in 8 days
View Details
NAICS: 811420
SLED
City Seal Removal, Stabilization, Assessment & Restoration
Solicitation # 2026-REQ-008
The City of Ellsworth is soliciting proposals from qualified historic preservation contractors and conservation firms for the phased removal, stabilization, assessment, and restoration of the historic City Hall Seal Pediment. This 91-year-old hand-carved wooden relief, located on the front gable of City Hall, requires specialized care adhering to the Secretary of the Interior's Standards for the Treatment of Historic Properties and accepted standards for the preservation of historic wood. The project is structured in two principal phases, with Phase 1 focusing on the safe removal, detailed documentation, and transport of the Seal to a secure, climate-monitored environment for gradual moisture equilibration and professional condition assessment. Phase 1 deliverables include a detailed rigging plan, site protection, controlled disassembly, and the creation of a comprehensive Condition and Assessment Report with specifications for Phase 2. The contractor is responsible for the identification and preservation of all loose or detached fragments and must ensure the Seal is stored in a facility that prevents further deterioration. No permanent repairs or restoration may occur during the first phase without written authorization from the City. Following the assessment and drying process, a second review will determine the final conservation and restoration requirements for the reinstallation of the Seal using appropriate anchoring systems and materials.
Facilities

POSTED

23 days ago

DEADLINE

in about 1 month
View Details