Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on August 15, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

117th Backflow Preventers

Closed
W50S6M-25-Q-A017Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

This contract involves the procurement of the ZURN 10" 375DA Double Check Valve Backflow Preventer or an equivalent device, designed to safeguard potable water systems from contamination caused by back siphonage and back pressure. The specified backflow preventer features a 10-inch size, with a maximum working water pressure of 175 PSI and a temperature limit of 140°F. It is tested to withstand hydrostatic pressures up to 350 PSI and includes end connections compatible with grooved steel pipes per AWWA C606 standards and flanged bolt patterns according to ASME B16.42. The assembly is certified to NSF/ANSI/CAN 61 and ASSE 1047 standards, ensuring compliance with health and safety regulations. Constructed with epoxy-coated ductile iron, stainless steel stems, NORYL check valves, and EPDM elastomer seat discs, the device allows for maintenance access without line removal and incorporates a metered bypass for leak detection and unauthorized water use monitoring. The contract is part of the 117th Backflow Preventers solicitation under the Department of the Army, specifically managed by the W7MT Uspfo Activity Alang in Birmingham, Alabama. It is designated as a total small business set-aside under NAICS code 332919, emphasizing participation from small businesses. The response deadline is August 28, 2025, with contact points including Jonathan Werkmeister and William K. Hall for inquiries. The procurement aims to ensure reliable installation of backflow prevention devices in water systems associated with fire protection, emphasizing compliance with safety standards and operational efficiency.

General Info

Small business set-aside for ZURN 10" double check valve backflow preventer for National Guard.

NAICS

332919 - Other Metal Valve and Pipe Fitting Manufacturing

Place of Performance

Birmingham, AL, 35217, USA

Set-Aside

SBA

Documents

4

Provisions and Clauses - Backflow Preventer

PDF, High priority: read this firstcontract-document
High

Solicitation W50S6M-25-Q-A017: Backflow Preventer

DOCX, High priority: read this first3 pages · rfq
High

Statement of Requirement - CE Backflow Preventer

DOCX, High priority: read this first2 pages · sow
High

Zurn Wilkins Model 375DA Backflow Preventer Specifications and Quote

PDF, High priority: read this firstspecifications
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7MT Uspfo Activity Alang 117
Contacts2 people available
OfficeBIRMINGHAM, AL, 35217-3595, USA
Office AddressBIRMINGHAM, AL, 35217-3595, USA

Full Description

Show more
ZURN 10" 375DA Double Check Valve Backflow Preventer (Or Equal). Key features: ? Sizes: 10 ? Maximum working water pressure 175 PSI ? Maximum working water temperature 140'F ? Hydrostatic test pressure 350 PSI ? End connections (Grooved for steel pipe) AWWA C606, (Flanged bolt pattern) ASME B16.42 Specifications: ? The Reduced Pressure Detector Backflow Prevention Assembly shall be certified to NSF/ANSI/CAN 61, ASSE Listed 1047, and supplied with full port OS & Y gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NORYL, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks and the relief valve shall be accessible for maintenance without removing the device from the line. The Reduced Pressure Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 375DA. Application: ? Designed for installation on water lines in fire protection systems to protect against both back siphonage and back pressure of contaminated water into the potable water supply. The Model 375DA shall provide protection where a potential health hazard exists. Incorporates metered by-pass to detect leaks and unauthorized water use. Additional details can be found on the Purchase Description.

More opportunities from Department Of Defense → W7MT Uspfo Activity Alang 117

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS