Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on April 11, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

2330--GE SIGNA Voyager 12x60 Transportable MRI Unit

Closed
36C26024Q0490Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 336212
New
Federal
Towed Array Transporter and Dockside Handling
Solicitation # N6660426Q0307
The Naval Undersea Warfare Center Division, Newport is seeking a Firm Fixed Price contract for a towed array transporter and dockside handling system. The system must accommodate a removable reel with a 60-inch hub, 87-inch flange, and 68-inch width, supporting stable reeling operations with a minimum 4x structural safety factor. Technical specifications require a 240VAC single phase electric motor with a maximum 35 amp draw, reeling speeds between 0 and 15 RPM, and adjustable back tension from 0 to 650 lbs. The contract includes a primary deliverable for the system, with options for a maintenance and sustainability plan and a technical data package, alongside required data deliverables per the Contract Data Requirements List. Award will be based on best value, evaluating technical approach, firm fixed pricing for CLINs 0001 through 0003, a proposed milestone schedule, and past performance. A critical technical requirement is the detailed explanation of corrosion prevention measures for long-term operation in salt water pier side environments. To be eligible for award and access to export-controlled technical drawings, offerors must possess a valid Joint Certification Program certification and have a NIST SP 800-171 DoD Assessment and a CMMC Level 2 self-assessment or higher posted in the Supplier Performance Risk System. All equipment must conform to National Highway Transportation Safety Administration standards and include specific safety features such as electric brake mechanisms at each wheel and recessed lighting.
Nuwc Division Newport

POSTED

about 10 hours ago

DEADLINE

in 22 days
NAICS: 336212
New
Federal
Northern California Area Office (NCAO) Low Bed Tra
Solicitation # 140RR027Q0023
Solicitation 140RR027Q0023 is a firm fixed price contract issued by the Bureau of Reclamation’s Northern California Area Office for the procurement of a new 2027 lightweight 35-ton, 2-axle, 2-frame, 8-tire, air flip tail low bed trailer with a detachable gooseneck. The equipment must be constructed from 100% T-1 high tensile Swedish Strenx 700 steel and finished with two coats of Imron Brand acrylic polyurethane paint in Federal standard Grey. The trailer must comply with California Vehicle Code 27600. This requirement is a total small business set-aside under NAICS code 336212. The contractor is responsible for all manufacturing, assembly, labor, and shipping to the destination in Shasta Lake, California, with an anticipated delivery window of 120 days. Award will be based on the most advantageous offer considering technical ability to meet specifications, past performance via CPARS, and price reasonableness. Key requirements include the submission of technical drawings for COR approval prior to fabrication and the provision of internal quality control documentation before delivery. Final acceptance is contingent upon a comprehensive on-site inspection by a government mechanic and the COR. The contractor must provide a one-year manufacturer's warranty along with all necessary titles, VINs, and maintenance manuals. Quotes must be submitted in PDF format to Erma Clark by November 16, 2026, and must remain valid for 90 days. Payment will be processed electronically through the U.S. Department of Treasury's Invoice Processing Platform.
Reclamation Contracting Activity

POSTED

1 day ago

DEADLINE

in 18 days

General Info

NAICS

336212 - Truck Trailer Manufacturing

Place of Performance

VA Portland Healthcare System Vancouver Campus, Vancouver, WA, 98661, VIR

Set-Aside

NONE

Documents

1

Sources Sought - MRI Trailer for GE SIGNA Voyager (36C26024Q0490)

DOCX, Low priority8 pages · sources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Contacts1 person available
OfficeVANCOUVER, WA, 98661, USA
Office AddressVANCOUVER, WA, 98661, USA
Contacts
Krystal WeeksContracting Officer

Full Description

Show more
SOURCES SOUGHT NOTICE THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL OR QUOTE; THE VA IS NOT SEEKING PRICING OR OFFERS. The Department of Veterans Affairs, VISN 20, in support of the Puget Sound VA Healthcare System, is performing market research to compile data regarding: (1) The availability and capability of qualified small business concerns; (2) Identify if there are sufficient number of qualified Service-Disabled Veteran-Owned Small Business, Veteran Owned Small Business, HUB Zone 8(a), Women-Owned Small Business, or Small Disadvantaged Business, Small Business concerns relative to the subject North American Industry Classification System (NAICS) code. Responses to the information requested will assist the Government in determining the appropriate procurement method, including any set-aside decision. Respondents should clearly describe their capabilities to include management experience, equipment and personnel or the ability to obtain them. Furthermore, interested sources must also meet all requirements of Federal, State, and Local Municipal codes regarding operations of this type of service. The NAICS code assigned is: 336212 Truck Trailer Manufacturing The small business size standard is 1,000 employees. Not responding to this Sources Sought does not preclude participation in any future or potential solicitation, or Request for Quotation. It is the intent of the Portland VA Healthcare System to use the information gathered for market research purposes only. If a formal solicitation is released, it will be posted via the Contract Opportunies on Sam.gov. DESCRIPTION OF THE REQUIREMENT: The Department of Veterans Affairs (Everett CBOC 220 Olympic Blvd, Everett, WA 98203) is seeking to purchase, on a brand-name or equal basis, a 12X60 MRI trailer to allow for the easy transportability of the unit. This is just for the purchase of the trailer; the MRI unit is currently being held by GE. Essential/significant physical, functional, or performance characteristics. 12x60 Transportable MRI Trailer Brand/Manufacture Name AMST a Kentucky Trailer Company. Since this is a trailer being built to house the GE Voyager MRI and therefore must comply with the MRI manufacturer s requirements for a mobile housing for the for the MRI. Any small business must show they have experience manufacturing these types of trailers. MRI Trailer Overall length: 60 Overall height: 13 -6 Overall width: 12 Custom Chassis: o Custom built dual twin I-beam flat floor aluminum chassis o Four (4) fixed jack stands for rear of trailer o Two (2) manual landing legs with pins located in the front of the trailer o All aluminum wheels and radial tires o Air ride suspension o Spread axle with air ride rear suspension o Anti-lock brakes Custom Body: o Wall construction to include aluminum tube o Magnetic steel shielding per OEM requirements for VA Puget Sound specific 1.5T MRI system to be integrated into unit. Gauss line will be maintained below 5 gauss at any point beyond 6 from any side wall o Exterior sheet 0.50 raw aluminum o Entire unit painted white o Polyurethane spray foam insulation between tubes to provide barrier to heat, cold and noise o Vapor barrier installed on floor of trailer to resist moisture o Drip rails over main entry door and all along the top of the unit o Mirror image orientation with entry doors located on the driver s side of the unit Exterior Features o All aluminum lower belly box compartment area. To include lockable storage with aluminum insulated doors and gas cylinders o Staff entry door and stairs for direct access to unit with handrails on all sides o Bubble levels mounted on the unit o Swinging door (into MRI trailer) to allow for unit to connect to Zone 2 MRI trailer o Vinyl skirting around perimeter of unit to protect exposed areas to the elements o Steel combination lockbox mounted on the front of the trailer for key storage General Layout o Unit will meet all specifications that the MRI OEM has developed regarding the siting and installation of their MRI system into a transportable unit o Mirror image orientation o MRI scan room at the rear of the unit o Technologist control room in the middle of the unit o Linen storage area with shelves for clean and soiled linen o Swing door to allow for direct connection between zone 2 MRI trailer and MRI trailer o Front equipment room for OEM computer equipment and transportable support systems including electrical and HVAC systems Flooring o Plates to mount system and equipment in Scan Room and equipment room. o Single piece vinyl flooring throughout entire trailer to include plywood sub flooring Walls, Cabinets and Counter Tops o Solid surface countertops in Scan Room and Control Room o Cabinetry located in the Scan Room and Control Room o Coil and phantom storage in scan room o Walls to be built with hospital grade wall covering for ease of cleaning and longevity Ceiling and Lighting o Fully dimmable LED lights to be provided throughout the trailer o Sound reducing drop ceiling with acoustical ceiling tiles o Ceiling to include A/C louvers for proper dispersion of air flow o Separate lighting controls located in each room Magnetic Shielding o Shielding per manufacturers specifications in the Scan Room on each wall and the back of the unit where the rear door is located o Gauss field will be maintained below 5 at all points 6 away from outside walls o 44 wide pneumatic scan room door RFI Shielding o Aluminum RFI shielding lightweight and non-oxidizing. Installed to the specifications of the system manufacturer. Third party RFI testing company to confirm compliance RF Windows o Window between the Control Room and Scan Room is designed for ease of viewing but also RFI compliance o Auto fogging capability for privacy Communications o Three (3) Phone, fax, and Seven (7) data connection conveniently located in Control Room and lower compartment. (2) 15.24m Hubbell Data cords and (1) Phone cord supplied with unit. Electrical o Main 480 Volt AC disconnect for system located in lower compartment o Electrical distribution panel located in Equipment Room to allow for ease of serviceability and maintenance o 480 volt, 3 phase power o Shore power cable provided in the underbelly storage compartment o 12-volt DC charger/inverter provided o Interior Emergency lighting installed to provide illumination when the unit has lost power o DC power supply in belly box area along with another power supply for the battery charger o 45kw on board generator to provide emergency back-up power in the event of power loss. Generator provides sufficient power to run cold head to prevent helium loss, HVAC system, and transportable lights o Automatic Transfer Switch that starts generator if shore power supply is interrupted o The generator does not provide sufficient power to support scanning operations Air Conditioning/Heating o Northern Air combination HVAC/Chiller system mounted at the front top of the transportable unit. This system provides both environmental heating and cooling as well as all chilled water requirements for the MRI system This system eliminates the need for an OEM supplied external chiller o Separate air supplies to go to the different rooms o Louvers in the ceiling are designed for minimum downdrafts but still maintain proper air flow throughout the unit o Thermostats are set at out facility before shipping to maintain proper temperature Miscellaneous o AM/FM stereo receiver with CD and iPOD interface installed in Control Room. Speakers to be installed in unit o Site Planning Guide to be provided at time of deposit received o Manuals for all components to be provided on board unit at time of delivery o Fire extinguishers, handheld ABC all purpose, located in each room o Fire suppression system (Dry System) o Code Blue Alert System o Nurse Call Alert System o Prep for customer supplied patient injector o Install customer supplied patient injector o Sky Factory Sky light 6 x4 over MRI Table in scan room o Wall mural in scan room o Medical Gas Outlets 02/Air/Suction Provide outlets in the scan room and outlets in the underbelly compartment o Wave guide pass through scan room wall o Custom candy cane quench vent o Rigging support to OEM installation team during mechanical installation process at trailer company production facility o Transportation to Everett CBOC 220 Olympic Blvd Everett, WA 98203 Warranty o 1-year warranty Coordination o Coordinate transport of trailer with the facility POC o The facility COR will coordinate OEM personnel with trailer manufacturer for the installation of the GE MRI unit o Kickoff meeting with trailer vendor, POC, and GE Healthcare o Design review prior to trailer and MRI going into production o Immediately after production of trailer and when the MRI is shipped from GE to trailer vendor o During delivery/installation of MRI into the trailer o Prior to trailer and coming being delivered to Everett location o During installation at Everett location The information above is intended to be descriptive, not restrictive, to indicate the quality of equipment that will be satisfactory. It is the responsibility of the interested source to demonstrate to the Government that the interested source can provide equipment that fulfills the required specifications. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program: [ ] yes [ ] no - Small Business (SB) [ ] yes [ ] no - HUBZone [ ] yes [ ] no - Small Business 8(a) [ ] yes [ ] no - Small Disadvantaged Business (SDB) [ ] yes [ ] no - Women-Owned (WO) Small Business [ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no - Veteran Owned Small Business (VOSB) [ ] yes [ ] no - Large Business [ ] yes [ ] no - Other (please specify) [ ] yes [ ] no Are you the Original Equipment Manufacturer (OEM)? [ ] yes [ ] no If not the OEM, are you an authorized distributor, and can produce a letter from the OEM? [ ] yes [ ] no Is this product available on your GSA/FSS or other GWAC Contract? If so, what is your contract number?_____________________ [ ] yes [ ] no Does your equipment conform to the Buy American Act and FAR 52.225-1? 52.225-1 Buy American-Supplies | Acquisition.GOV What is the estimated Delivery Date After Receipt of Order (ARO)? _____________ Please include the following information: Company Name: POC: UEI: Address: Email: In addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, experience etc.) to confirm the company s ability to meet the requirements outlined in this request. Disclaimer: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. After review of the responses received, a pre-solicitation synopsis and solicitation may be published in Federal Business Opportunities (http://www.fbo.gov). Submit Capability Statements to: Department of Veterans Affairs, VISN 20 Attn: Krystal Weeks, no later than 3:00 PM (PST), April 8, 2024. Responses must be submitted via e-mail to: contact@example.gov. Note: Do not include Proprietary, classified, confidential, or sensitive information in responses.

More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)

Same awarding agency

NAICS: 238220
New
Federal
J041--White City B249 SE HVAC Repair
Solicitation # 36C26027Q0102
Solicitation 36C26027Q0102 is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) issued by the Department of Veterans Affairs. The contract requires the repair of a Mitsubishi R-410A comfort-cooling system (Serial 07W0090) located on the southeast side of Building B249 at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The scope of work includes leak detection, brazing repairs with nitrogen purge, refrigerant recovery, evacuation to less than 500 microns, and recharging the system to nameplate requirements. The contractor must provide a detailed service report documenting the root cause, repair actions, and compliance with EPA Section 608 and VHA ICRA/PCRA controls for occupied healthcare facilities. The period of performance is 30 calendar days from the Notice to Proceed. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, considering price and other specified factors. Key regulatory requirements include adherence to OSHA 29 CFR 1910.147 for lockout/tagout and 29 CFR 1910.333 for electrical safety. Payments will be processed via Electronic Funds Transfer, and invoices must be submitted electronically through the Tungsten Network. Offerors must provide their Unique Entity Identifier and maintain firm pricing for 60 calendar days from the response deadline of November 10, 2026.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in 12 days
View Details
NAICS: 334513
New
Federal
Boiler Plant O2 Sensor Replacement
Solicitation # 36C26027Q0101
The Department of Veterans Affairs, through the Network Contract Office 20, is conducting market research via a Sources Sought Notice for a firm-fixed price service contract to perform inspection, testing, maintenance, and repair of three model 6888 Rosemount flue gas analyzers. The work will be performed at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The primary scope involves replacing internal O2 analyzer components using original equipment manufacturer parts, specifically 18 inch standard cells, 18 inch heater strut assemblies, Hastelloy with Vee Deflectors for service up to 1300 degrees Fahrenheit, and new flange gaskets. The period of performance is six months, with on-site work required during core hours of 7:00 AM to 4:00 PM, Monday through Friday. This opportunity is designated as a total Small Business Set Aside under NAICS code 334513, with a size standard of no more than 750 employees. Qualified sources, including SDVOSB and VOSB entities, must provide company details, SAM.gov UEI numbers, and proof of manufacturer authorization if they are not the OEM. Contractors must employ qualified personnel, maintain general third-party liability insurance per FAR 52.228-5, and adhere to NEC, OSHA, and JCAHO standards. Deliverables include written daily reports to the Deputy Chief Facilities Management and testing documentation provided to the Contracting Officer's Representative. Interested parties are requested to provide a courtesy quote and capability statement to assist the government in evaluating price reasonableness and market availability.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

2 days ago

DEADLINE

in 5 days
View Details
NAICS: 325998
New
Federal
Microbiological media purchase order for Clinical Microbiology laboratory.
Solicitation # 36C26027Q0104
The Department of Veterans Affairs Network Contracting Office 20 is seeking sources for a microbiology testing media purchase order to support the Seattle Division of the VA Puget Sound Medical Center. This requirement covers a wide range of critical supplies for identifying pathogenic organisms in veteran patients, including long shelf-life products like Oxidase and Indole, perishable selective agar, biochemical test kits, and ATCC organisms mandated by the College of American Pathologists for quality control. The contract is structured with a base year running from February 1, 2027, to January 31, 2028, followed by four subsequent one-year option periods ending January 31, 2032. Deliveries are to be made to the Microbiology Lab in Seattle, with weekly shipments typically scheduled for Tuesdays and individual requests fulfilled as available. Due to the perishable nature of many items, the vendor must provide tracking information, and the cost of next-day delivery for all perishable goods must be included in the individual item price. All temperature-liable products require immediate refrigeration upon delivery. Invoicing is processed through the Austin Automated Payment System in Texas, and the vendor must provide SDS sheets for all media upon request. This sources-sought notice specifically looks for capable sources, including qualified SDVOSB/VOSB entities, with a response deadline of November 10, 2026.
All Other Miscellaneous Chemical Product and Preparation Manufacturing

POSTED

2 days ago

DEADLINE

in 12 days
View Details
NAICS: 238220
New
Federal
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System
Solicitation # 36C26027R0014
Solicitation 36C26027R0014 is a negotiated request for proposals for the Department of Veterans Affairs to correct domestic water system deficiencies in Buildings 1 and 12 at the Mann-Grandstaff VA Medical Center in Spokane, Washington. The project is 100% set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 238220, with an estimated contract magnitude between $1 million and $2 million. The primary objective is to modify hot and cold potable water distribution systems to comply with VHA Directive 1061 for the prevention of scald injuries and Health Care-Associated Legionella Disease. The scope includes all labor, materials, and equipment, with a specific requirement to flush potable water dispensing fixtures twice weekly from installation until final acceptance. The period of performance is 275 calendar days from the Notice to Proceed. The government will utilize a Best Value tradeoff process for award, prioritizing technical experience and past performance over cost. Technical evaluations will favor offerors with demonstrated experience in phasing and Infection Control Risk Assessment (ICRA) within 24-hour operational emergency rooms. Proposals must be submitted in three separate volumes—Technical, Past Performance, and Price—by November 23, 2026. Awardees must provide performance and payment bonds, adhere to Davis-Bacon Act wage determinations, and comply with Buy American requirements. Additionally, the contractor must maintain strict confidentiality regarding sensitive information and provide a one-year warranty on all materials and installation.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

2 days ago

DEADLINE

in about 1 month
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS