Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Alabama was posted on May 30, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

24031R0698/Work on trailer #3-S0082A

Closed
SRC0000022340State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237130
New
SLED
115kV Transmission Line 1266 Rebuild Stanton North Substation to Dead-End Structure 79
Solicitation # 26-012
Nebraska Public Power District is soliciting sealed bids for Contract No. 26-012 to rebuild approximately 4.05 miles of the 115kV transmission line 1266, extending from the Stanton North substation to Dead-End Structure 79. The scope of work includes the installation of 28 wood H-Frame tangent structures and one steel monopole dead-end on a drilled pier. Additionally, the project requires upgrading existing conductors and shield wires to 954 45/7 ASCR Rail conductor and 7/16 inch EHS steel shield wire, as well as the installation of .551 diameter fiber optic ground wire from Structure 107 to Dead-End Structure 79. The contractor is responsible for providing all necessary labor, supervision, tools, equipment, and miscellaneous materials. The contract will be awarded to the responsible bidder offering the lowest cost and best bid, with evaluation factors including price, technical conformance, schedule, qualifications, and performance history. Bids must be submitted in sealed hard copy form to the Procurement Department in Columbus, Nebraska, by December 2, 2026, at 2:00 PM. Required submission documents include the proposal page, price quotation table, bid security, and a W-9 form. The contractor must maintain comprehensive insurance, including workers compensation and commercial general liability, and provide a contract performance bond. A non-mandatory pre-bid teleconference and site visit are scheduled for November 23, 2026.
Nebraska Public Power District

POSTED

about 7 hours ago

DEADLINE

in about 1 month
NAICS: 237130
New
SLED
Traffic Signal Synchronization Project Along Hamner Ave And Archibald Ave
Solicitation # 26-119CIP
The City of Eastvale, California, is soliciting bids for the Traffic Signal Synchronization Project Along Hamner Avenue and Archibald Avenue under solicitation number 26-119CIP. The project involves the installation of traffic signal controllers, field ethernet switches, fiber optic trunk and breakout cables, and conflict monitor units, as well as the implementation of hybrid detection systems. The scope includes significant infrastructure work such as installing PVC conduits, pull boxes, and performing pavement restoration. All work must be completed within 50 working days from the commencement date and must adhere to the standards of the County of Riverside, Caltrans, and the Americans with Disabilities Act. The contract will be awarded to the apparent low bidder based on the total bid price, including the base bid and specific alternates. To be eligible, the prime contractor must hold a current California Class A General Engineering Contractor license. Required submission documents include a signed bid form, bid security, a statement of qualifications, and a non-collusion declaration, all submitted via the PlanetBids portal. The selected contractor will be required to provide construction performance, labor and material payment, and warranty bonds. Payment will be administered on a lump sum basis according to an approved schedule of values, with final payment contingent upon the submission of project record drawings and the execution of a release of claims.
City of Eastvale

POSTED

1 day ago

DEADLINE

in 15 days
NAICS: 237130
New
Federal
CSSC Utility Feed Transformer Replacement
Solicitation # W912P627SSA001
The U.S. Army Corps of Engineers, Chicago District, is conducting market research via Sources Sought Notice W912P627SSA001 to identify qualified small business contractors for the turnkey removal and replacement of two utility feed transformers at the Chicago Sanitary and Ship Canal Fish Dispersal Barrier facility in Lockport, Illinois. The project involves the removal and disposal of two existing 4,000/5,000 kVA transformers and the installation, testing, and commissioning of two new operational replacements. The contractor will be responsible for all labor, materials, equipment, rigging, and supervision, while existing concrete pads, cabling, and switchgear will be reused. The estimated magnitude of construction is between 500,000 and 1,000,000 dollars, with an estimated project schedule of 365 calendar days. Interested firms must demonstrate technical capabilities in medium-voltage electrical work, including pre-energization electrical acceptance testing in accordance with NETA ATS and IEEE C57 standards. Key requirements include the ability to supply biobased dielectric insulating fluid and steel enclosures with recovered materials, as well as strict adherence to USACE EM 385-1-1 and NFPA 70E safety standards. Applicants must provide their small business status under NAICS code 237130, proof of bonding capacity, and up to three relevant project examples from the last five years. Responses, which should not include price quotes, are due by November 5, 2026, and must be submitted using the provided response template.
W072 Endist Chicago

POSTED

1 day ago

DEADLINE

in 8 days

AI Contract Overview

Show more

The contract involves the comprehensive replacement and upgrade of electrical components on a tower trailer designated as trailer #3-S0082A. The scope includes removing and installing all existing SO electrical cables and connectors on the tower unit, ensuring all cabling connected to the tower control panel, scope motor, and hydraulic pump motor are replaced with new wiring. Additionally, all existing limit switches will be replaced with new Square D (Sq.D) limit switches, and the tower lockout cable assembly will be removed and replaced with a new cable. The scope motor will be removed and replaced with a new OEM Baldor 1HP motor, and the fiberglass control panel will be replaced with a new unit. The project aims to ensure the electrical and control systems are fully updated and operational. The solicitation, titled "24031R0698/Work on trailer #3-S0082A," was posted on May 30, 2024, with a response deadline of June 4, 2024. It is a competitive procurement under NAICS code 237130, with a contract value estimated between $5,000 and $15,000. The work will be performed in Alabama, under the jurisdiction of the Alabama agency, and is open to qualified contractors. Interested parties can find additional details and manage the solicitation process through the provided online link.

General Info

Documents

1

Alabama State Standard Terms and Conditions for Quick Quote Solicitations

PDF, High priority: read this first4 pages · other
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyAlabama
ContactsNo contacts available
OfficeN/A
Organization / AgencyAlabama
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Replace all SO electrical cable on towerunit of one tower trailer. All SO cable and allconnectors for SO cable replaced with newThis includes all cabling ran to tower contropanel and to scope motor and hydraulic pounit motor. Also all new Sq.D limit switches.R&R tower lock out cable assy, new cableR&R scope motor, new OEM Baldor 1HPReplace Fiberglass control panel w/new 

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS