36 -- UPGRADE LUCKER MODEL M PROOF PULL TESTER MACHINE

Active
Reference-Number-V47316-4198-7S92Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The contract involves upgrading the existing Lucker Model M Proof Tester machine, which has a load capacity of 200,000 lbs and is located at the Naval Station Ingleside in Texas. The upgrade includes retaining the current main bed section while enhancing the control panel by replacing the old controller with a new digital one, adding a hydraulic grip, and integrating computer software capable of tracking test data. The upgraded system must maintain compatibility with the existing Model M Proof Tester and include an advanced active control mode to prevent excessive loading, automatic calibration and recognition of sensors, and independent dedicated controllers to ensure data integrity and safety. The equipment will feature enhanced sensor conditioners that detect cable faults and prevent operator errors, and the electronics will be isolated from PC-generated noise. The upgrade also specifies improvements to the load frame and data handling capabilities, including a test control panel with programmable keys, a no-clutch electromechanical loading unit for reliability, and symmetrical drive systems to prevent crosshead tilting. Data acquisition must sample load, strain, and position at high rates with extensive data storage options and high accuracy according to ASTM standards. The system will provide multiple live and analog data displays, real-time graphing with selectable parameters, and comprehensive diagnostics. This contract will be awarded on a sole source basis to Instron Corporation, utilizing their 5500 Servo Control extend upgrade system with necessary accessories to achieve all functional and safety requirements.

General Info

Upgrade Lucker Model M tester with digital controls, hydraulic grip, enhanced data, safety, and real-time diagnostics.

NAICS

334519 - Other Measuring and Controlling Device Manufacturing

Place of Performance

FL

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Navsup Flt Logistics Ctr Jacksonville
Contacts1 person available
OfficeJACKSONVILLE, FL, 32212-0097, USA
Office AddressJACKSONVILLE, FL, 32212-0097, USA
Contacts
Maria H GaunttPurchasing Agent

Full Description

Show more
Specifications to upgrade existing Lucker Model M Proof Tester 200,000 LBS capacity, S/N 6145 B, located at Shore Intermediate Maintenance Activity, 120 Coral Sea Road, onboard Naval Station Ingleside, TX 78362. The machine is composed of a power unit, a main bed section which contains the hydraulic cylinders and powered crosshead assembly. The electrical schematic is detailed in Amhoist (Model - M electrical sch.) Dwg # 1461014. The hydraulic schematic is detailed in Amhoist (Model - M hydraulic sch.) Dwg # 1461042. Load monitor system is standard. Power unit is Length 41 width 32 and height 81. Main bed length is 20 width 60 and height 36. Unit capacity is 200,000 lbs. Hydraulic reservoir capacity 5 gallons. Motor (3) hp. Connection (480) v. (3) ph. (60) hz. Hydraulic cylinders: bore (5) stroke (48) Rod Dia. (2 - ). Load Recorder circular chart. Grip crosshead & cable grip. Bedway guards are manual w/ interlock. Cable grip size is 99. Liner wedge size is 2 . It pulls slings to weight 0-200,000 lbs and holds it for specified lengths of time then the tension is released. There are no restrictive environmental conditions. Used to pull test boat and minesweeping slings, wire pendants and perform pull tests. Current main bed to be retained and have the control panel upgraded to digital, and a hydraulic grip added. The old controller taken out and have new one installed that reads digital. Computer or software that is connected or can be connected to the machine to track the readings during pull tests. The new equipment must interface and be compatible with our current Model M Proof Tester. The Testing Instrument shall include an active control mode to protect against excessive load being applied to the test specimen during loading into grips or fixtures prior to starting the test. This mode shall function at the stated load weighing system accuracy and include an automatic turn-off at the start of a test. The Testing Instrument shall provide automatic recognition and automatic calibration of transducers (load cells and extensometers). The system shall have critical functions handled by a dedicated controller independent of PC. Then sensor conditioners, digital control and data acquisition electronics must be located outside the PC chassis to reduce exposure to electrical noise from the PC's internal power supplies and boards. Each sensor conditioner shall have the capability to detect cable faults and signal loss for operator and system safety. The conditioners must be capable of detecting disconnection of the transducer and must prohibit the operator from attempting to use that conditioner for control. Sensor Conditioners that utilize plug in range cards are not acceptable. Each signal conditioner shall use AC excitation to reduce noise. The System shall include self-test diagnostics with an external display for hardware and communication status. LOAD FRAME: The System shall include a test control panel for start, stop, return, jog, fine jog, and specimen protect functions. The panel shall also include at least two programmable keys for load balance, strain balance, exclude specimen, and other functions. The load frame column covers shall have at lease two t-slots each to allow for attachment of accessories such as a protection shield, test area lighting, extensometers, control panels, etc. The electromechanical loading unit shall employ a no-clutch design for better reliability, less maintenance, and improved load/speed performance. The System shall have auto-switch to frame standby mode to ensure safety if PC is shut down accidentally, power is lost, or the PC fails A digital controller shall provide at least 500 hz of digital closed-loop control for crosshead motion. The load frame shall have a symmetrical drive system to eliminate differences in lead screw phase that results in tilting on the crosshead. DATA HANDLING: The System shall sample load, strain and position data a minimum of 40 kHz and save data at up to 500 Hz simultaneous on all channels. The system shall be capable of storing an unlimited number of data sets per test. Each data set shall include load, stress, strain, extension, time and average strain. Automatic and user selectable data acquisition modes shall be provided. The System shall allow the user to choose data logging at fixed time intervals or incremental data logging based on a combination of load, position and strain intervals. The system shall allow storage of test sample data in individual files to minimizing data loss in the event of file corruption. The load measurement accuracy shall be +/- 0.5% or reading down to 1/250th (0.002%) of the load cell capacity according to the latest ASTM E4 standard method. Load system resolution shall be constant over the full range of the load cell. DATA DISPLAY: The system shall provide up to four, live numerical data displays with selectable engineering units. The user shall be able to change the selection of display variables during a test. Data available for display shall include load, stress, strain, extension, time, cycle count, average strain, differential strain, and strain from extension. The Testing System shall provide up to four selectable analog data displays in addition to the numerical displays. The analog displays shall be independently scaleable and shall include current value, event value, and limit values for each channel. The System shall provide a real-time graph of test data. The user shall be able to change the graph axes and select data channels during the test. The System shall display multiple graph curves and multiple results data simultaneously. This shall be a sole source unresticted basis negotiated solicitation with Instron Corporation, 100 Royall Street, Canton, MA 02021-1089. The 5500 Servo Control extend upgrade system with accessories will be used to complete the upgrade.

Similar Contracts

Same NAICS industry code

NAICS: 334519
New
DIBBS
PROBE, HUMIDITY-TEMPERA
Solicitation # SPE4A5-27-T-2034
Solicitation SPE4A5-27-T-2034 is a request for quotations from the DLA Weapons Support ASC Supplier Oper OEM Division for the procurement of 12 humidity-temperature probes, identified by NSN 6685008037705. This critical application item must adhere to basic specification MIL-DTL-27723F and utilize connector class H per MIL-DTL-5051H with pin arrangements following MIL-STD-1651A Appendix A. The contract requires a first article test consisting of three probes, with the resulting test report conforming to MIL-HDBK 831. A specific focus is placed on monitoring sensor resistance during testing to ensure conformance with section 3.4.2.1, as failure to maintain these values will result in sensor failure. The procurement is not a small business set-aside and requires compliance with the Buy American Act and the Berry Amendment. Delivery is set as FOB Origin, with inspection and acceptance also occurring at the origin. Packaging and marking must comply with MIL-STD-2073-1E and MIL-STD-129. Due to the nature of the materials, suppliers must provide Safety Data Sheets and Hazard Warning Labels for approval by technical personnel prior to award in accordance with 29 CFR 1910.1200. Administrative requirements include the use of the Wide Area WorkFlow system for invoicing and adherence to NIST SP 800-171 and DFARS cybersecurity standards for safeguarding covered defense information.
DLA WEAPONS SUPPORT ASC SUPPLIER OPER OEM DIVISION

POSTED

about 16 hours ago

DEADLINE

in 7 days
View Details

More opportunities from Department Of Defense → Navsup Flt Logistics Ctr Jacksonville

Same awarding agency

NAICS: 332323
Federal
Precision Metal Framing and Housing FabricationThe contract involves the fabrication of precision metal frames and enclosures specifically designed for the Heated Window Assembly, ensuring the components meet exacting standards for structural integrity and seamless integration into naval vessel systems. The work requires advanced manufacturing capabilities to produce components that are compatible with the demanding environmental and operational conditions of naval platforms, with strict attention to dimensional accuracy, material specification, and durability. The frames and housings must be engineered to support heating functionality while maintaining mechanical stability under vibration, thermal cycling, and corrosive sea exposure. Performance of the work is designated to take place in Jacksonville, Florida, with the contract issued under the NAICS code 332323 for fabricated metal product manufacturing. This is a subcontract arrangement within the Department of Defense procurement ecosystem, administered by Naval Supply Systems Command Fleet Logistics Center Jacksonville. The contract was posted on July 13, 2026, and the technical requirements reflect critical support for naval fleet readiness, where component reliability directly impacts crew safety and operational effectiveness. All deliverables must align with applicable military specifications and undergo rigorous quality verification prior to acceptance.
Ornamental and Architectural Metal Work Manufacturing

POSTED

4 months ago

DEADLINE

N/A
View Details
NAICS: 327215
Federal
Tempered, Heated Glass Fabrication for Aerospace WindowThe contract involves the fabrication of precision tempered glass with integrated heating capability for use in the Heated Window Assembly identified by Part No. CC-10367-1, specifically for aerospace applications. The work is scoped under a subcontract with a NAICS code of 327215, indicating classification within the glass product manufacturing industry, and is tied to the Department of Defense through the Naval Supply Systems Command Fleet Logistics Center Jacksonville. Performance of the contract is designated to occur in Jacksonville, Florida, with a zip code of 32228, and the solicitation was posted on July 13, 2026. The heated glass component must meet stringent aerospace standards for durability, optical clarity, and thermal performance under extreme environmental conditions. As a subcontract, the primary contractor is expected to manage compliance, quality assurance, and delivery timelines aligned with DoD requirements, though no set-aside type or specific point of contact is detailed. The contract supports critical defense systems requiring reliable window assemblies that maintain functionality through icing, temperature fluctuations, and high-stress operational environments. Execution will require advanced manufacturing techniques to integrate heating elements into tempered glass without compromising structural integrity or optical performance.
Glass Product Manufacturing Made of Purchased Glass

POSTED

4 months ago

DEADLINE

N/A
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS