Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 28, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

X1AA--36Q244235Q0528 | Georgetown Sussex Vet Center (MVC) BRAND Name or EQUAL Requirement Onan QD 12000, Model #: 12.0HDKCD-2209G 12 KW Mobile Generator - Deisel

Closed
36C24425Q0528Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 335312
New
Federal
Cummins C70D2RE mobile, trailer mounted Generators
Solicitation # W911S227U0066
The Army Test and Evaluation Command at White Sands Missile Range is seeking the procurement of three new Cummins C70D2RE mobile, trailer-mounted generators to support mission services. This acquisition is a total small business set-aside under NAICS code 335312, with the contract awarded to the responsible offeror deemed most advantageous based on price and technical evaluations. The required equipment must be new, as used or remanufactured products are prohibited. Key technical specifications include U.S. EPA Tier IV Final and EU SIIa certified Cummins QSB5-G11 engines, PowerCommand 3.0 control systems with Masterless Load Demand technology, and sound-attenuated, white powder-coated lockable enclosures featuring 24-hour fuel tanks. The units must also comply with CAN/CSA and NEMA MG1-1.65 standards. Offerors proposing equivalent products must provide detailed specification sheets, identify the brand and model, and describe any modifications necessary to meet the government's salient characteristics. The preferred delivery timeline is within 30 days after receipt of order, and all shipments must be FOB destination. Proposals must be submitted via the PIEE Solicitation module and include technical and price documentation, past performance, and a completed certification of the country of origin. Failure to use the PIEE portal or omit the required certifications may result in the offer being rejected as nonresponsive.
W6QM Micc-Ft Drum

POSTED

1 day ago

DEADLINE

in 5 days

General Info

NAICS

335312 - Motor and Generator Manufacturing

Place of Performance

Georgetown Sussex Vet Center 20653 Dupont Boulevard Suite 1, Georgetown, DE, 19947, USA

Set-Aside

NONE

Documents

2

36C24425Q0528.docx

DOCX

Sources+Sought+for+Georgetown+Sussex+Vet+Center+-+SourcesSought+RFI+-+12+KW+Cummins+Diesel+Generator.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseClosed
Posted

Sources Sought

Notice updated

Response deadline changed from Apr 3, 2025 to Apr 4, 2025. The notice title changed. The notice description changed.

Notice updated

Response deadline changed from Apr 4, 2025 to Apr 3, 2025. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)
Contacts1 person available
OfficePITTSBURGH, PA, 15215, USA
Office AddressPITTSBURGH, PA, 15215, USA
Contacts
Tyler KarnsLease Contract Specialist

Full Description

Show more
THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION ONLY. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Because this is a Request for Information announcement, no evaluation letters and/or results will be issued to the respondents. No solicitation exists. Therefore, do not request a copy of the solicitation and bids are not being accepted at this time. The Department of Veterans Affairs (VA), VISN 4, Network Contracting Office 4 (NCO 4), is seeking information and potential qualified sources capable of providing service work for removing and installing a Brand Name or Equal Generator with Model #: 12KW Cummins Commercial Mobile Generator Onan QD 1200, Model #: 12HDKCD-2209, for their Mobile Veteran Center (MVC). Services requested and received will based on the Government requirements identified in the Statement of Work SOW found below. The MVC is located at the Georgetown Sussex Vet Center, located at address: 20653 Dupont Boulevard, Suite: 1, Georgetown, DE 19947. Interested contractors are encouraged to apply, sending their responses to this RFI, should be directed to the Lease Contract Specialist: Tyler Karns, who will receive responses by email at: Tyler.Karns@Va.Gov. No phone calls will be accepted! Questions regarding this RFI should be sent by email within the first 48 hours of business based on the time this RFI is posted, and time stamped. All firms responding to this Request for Information are advised that their response is not a request for proposal, therefore responses to this (RFI) request for information will not be considered for a contract award. Any costs associated at preparing a response to this RFI are your own responsibility. Vendor, otherwise identified as the Contractor, shall provide the following services for the VA Staff relating to the SOW listed below: Statement of Work (SOW) Georgetown Sussex Vet Center 12 KW Diesel Generator Background: The Readjustment Counseling Service, Georgetown Sussex Vet Center had a required need for a new Brand Name or Equal - 12 KW Cummins Commercial Mobile Generator Onan QD 1200, Model#: 12HDKCD-2209G for their Mobile Veteran Center (MVC). The old generator has reached its life expectancy and is deemed unserviceable. Place of Performance: All work will be performed at the following address: Georgetown Sussex Vet Center 20653 Dupont Blvd., Suite: 1 Georgetown, DE 19947 Period of Performance (POP): The installation should take place within 120 days of award unless specified otherwise by VA (LCO) Lease Contracting Officer. At the time of Lease Amendment (LA) being awarded, the following day after the award date will mark commencement of the POP which runs 42 days. Past Performance: Interested parties submitting information for this request for information (RFI) shall submit (3) three references showing past performance of work being completed on similar sized vehicles and type, which is mobile travel cargo passenger busses. All related work references should be from the past (2) two years and considered as recent work service contracts being completed. Pick Up of VA MVC: The Georgetown Sussex Vet Center is requesting their MVC to be picked up and transported to the contractor s location where service and installation is to be completed. The Contractor: designated providing service installation of the new replacement generator will be responsible for providing the necessary removal of the old generator, installation of the new Brand Name or Equal Generator, and any necessary equipment to complete and ensure the generator is fully functional operating efficiently meeting the needs of the MVC for future deployment efforts. The following required tasks identified below are listed as follows: Inspection and Testing: Shall will consist of two cycles. The first cycle will be done at the contractor s place of business to ensure the generator is properly installed having the proper materials, including components attached to the MVC, and verifying the generator is running and operating functioning 100% free of any issues. The VA COR and his designated Engineer will conduct the testing with assistance of the contractor of one of the contractor s technicians. Any issues with the generator found during 1st cycle testing will require resolution immediately; otherwise, a second attempt at the 1st cycle testing will need to be conducted again at a later date. Warranty Policy: Details of the warranty policy shall be thoroughly explained to the VA COR and VA Engineer ensuring full agreement is understood by the VA and have necessary information for any future problem resolution issues with the generator given to them in writing. The VA wants a warranty policy that will virtually cover everything related to the Generator except routine maintenance for the first three years including parts, time and materials needed to ensure issue with generator is resolved. The exact details of the warranty policy will be agreed upon between the VA COR and the Contractor, if policy limits including any terms and conditions that are altered from the warranty being requested as a requirement, the agreed upon warranty policy will have additional terms and conditions provided and emailed as an attachment to the VA COR copying the AAMFT Approved Supervisor and the Lease VA Contract Specialist. The Warranty Policy details described in writing and agreed upon between the contractor and the VA COR and or AAMFT Approved Supervisor will be included as part of the LA prior to LA Award Date. Training given by Contractor: Once the generator is properly installed, the contractor will contact the following VA Staff Members identified as VA Contacts below: Title: VA Email Address Phone Number: Lease Contract Specialist Tyler.Karns@Va.Gov (412)-822-XXXX VA COR Identified later (XXX)-XXX-XXXX AAMFT Approved Supervisor Identified later (XXX)-XXX-XXXX Contractor will email VA COR copying the AAMFT Approved Supervisor and schedule an agreed delivery date with expected time for transporting the VA s MVC back to the Georgetown Sussex Vet Center (having logistic details in writing). On the delivery day, the contractor and or his technician will perform the 2nd Cycle of generator testing meeting with the VA COR and VA Engineer ensuring the generator is still working and functioning 100% free of any issues. If adjustments are needed to be made to the Generator, including any other changes, they shall be addressed by the contractor or his technician showing how adjustments are done to the VA COR and VA Engineer. There should be no found issues with the generator that are considered problematic during the 2nd Cycle of generator testing. VA staff members designated to receive training on the generator shall be present the same day and be prepared to receive training immediately follow the 2nd Cycle of generator testing is complete and approved by VA COR. The Contractor and or his technician knowingly have tips or strategies relating to adjustments or general maintenance for the generators upkeep this information should be included as part of the generator training session with VA staff members. Generator Specifications & Characteristics: Commercial Mobile Generator Onan QD 12000, Model #: 12.0HDKCD-2209G Weight: 815 lbs., Length: 41.5 inches, Width: 24.5 Inches, Height: 27.0 inches, Sound: 68 DB (A). Fan (internal), Hertz: 60, Watts: 12000, Voltage: 120/240, AMPS: 100/50, PF 1.0, Circuit breaker: (1) 2 Pole, 50A. icture is for visual and descriptive purposes but should NOT be considered 100% accurate! . 8.) Engine Details: Design: 4-cycle, liquid-cooled diesel engine, Cylinders: 4 inline vertical, Engine Model #: Kubota D1503-M Bore: 3.27 in, Displacement: 91.44(3rd) in., Stroke: 3.64 in., Compression Ratio: 23-1, Lube Oil Capacity: 5.9 qt., Cooling System Capacity: 6.6 qt., Combustion Chamber: Indirect injection, Power (max): At 1800 r/min 24.8 hp EPA Tier 4 non-road, Starting System: Remote, 12V. 9.) Alternator Details: Design: (Brand Name), brush type; drip-proof construction, 4 pole; Exciter System: Electronic voltage regulator, Insulation System: Electronic voltage regulator; Cooling: Direct drive centrifugal blower; Exciter System: Electronic voltage regulator 10.) Standard Features: Built in Self-Diagnostic capabilities; Brush Typer AC Alternator; Bottom air inlet and outlet configuration; Digital voltage regulation. 4-cylinder diesel engine; Integral enclosed muffler with stationary exhaust pipe connection point; Internal radiator; Intake silencer. USDA approved spark arresting muffler; Sound attenuated housing; Heavy duty air cleaner; Waterproof connector for remote operation. Maintenance free electronic governor; Hour meter; Regulated - Voltage 15 A battery charging; Electric fuel pump; long-life fuel filter. Over voltage; low oil pressure, over temp; over speed; overload and AC alternator over temp safeties Four-point; fully focalized internal mounting system reduces vibration with integrated secondary isolation system. Bulkhead type connections for fuel and battery; Terminal block connections for AC output; Spin-on, full-flow oil filter. Instant one touch stop; Automatic timed glow plugs for quick easy start; Service and maintenance from side service door. 11.) Average Fuel Consumption / Voltage & Frequency Regulation: Gasoline Type: Diesel, Full Load: 1.28 Gal/hr.; Half Load: 0.71 Gal/hr.; No Load: 0.38 Gal/hr. Voltage Regulation: No load / Full load - 2.0%; Constant load 0.5%. Frequency Regulation: No load / Full load - 0.1%; Constant load 0.6%. Questions: Will be responded to by contacting the Lease Contract Specialist, Tyler Karns, he can be reached by email at: Tyler.Karns@VA.Gov. /*************************************************************************************************END of SOW*****************************************************************************************************/ DISCLAIMER This RFI will be conducted in accordance with intent for Market Research Purposes which are under Federal Acquisition Regulation (FAR) Part 10. Telephone responses will not be accepted. Responses must be received via e-mail to Tyler.Karns@va.gov no later than, 12:00 NOON Eastern Standard Time (EST) on April 4th, 2025. This notice will help the VA in determining available potential sources only. Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All questions will be addressed by the Contract Specialist, Tyler Karns. This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

More opportunities from Department Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)

Same awarding agency

NAICS: 236220
New
Federal
Z1DA-- 460-26-004 | Wilmington VAMC Roof Replacement | NCO 4 Construction East (VA-26-00029152)
Solicitation # 36C24426B0015
Solicitation 36C24426B0015 is a sealed bid invitation for a firm-fixed price contract to perform roof replacement services at the Wilmington VA Medical Center in Delaware. The project involves the removal and replacement of Roof 3D, the Physical Therapy Roof, Roof 10, and Roof 11. The scope of work includes the installation of 60 Mil Elevate RubberGard EPDM LS-FR white roofing material or an equivalent, flat tapered insulation, and HD cover board, as well as the inspection and replacement of deteriorated metal decking. All installations must meet high wind zone design requirements and include a minimum 20-year warranty against leaks. The estimated construction magnitude is between $250,000 and $500,000. This procurement is a 100% set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). To be eligible for award, bidders must be registered in the System for Award Management (SAM), VETCERT, and the VETS-4212 database. Award will be granted to the responsive and responsible bidder offering the lowest price. Key requirements include compliance with Davis-Bacon wage determinations for New Castle County, Delaware, and strict adherence to OSHA safety standards, requiring a 30-hour certified competent person on-site. Performance and payment bonds are required for contracts exceeding $150,000. The final bid opening is scheduled for November 4, 2026, at 11:00 AM EST.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 14 days
View Details
NAICS: 334516
New
Federal
6550--VISN 4 Coagulation Testing
Solicitation # 36C24427Q022
The Department of Veterans Affairs, Network Contracting Office 4, is soliciting an indefinite-quantity contract for advanced coagulation testing and monitoring services to support nine VA Medical Centers. The scope of work includes the delivery, installation, and removal of a self-contained coagulation testing system capable of performing Prothrombin Time, Activated Partial Thromboplastin Time, International Normalized Ratio, International Sensitivity Index, Fibrinogen, D-Dimer, and Anti-Factor Xa tests. The period of performance is established from December 1, 2026, through November 30, 2031. Technical requirements specify a bi-directional, bar-coded computer interface compatible with the VA laboratory information system and Beckman Coulter Remisol software, with a barcode reading failure rate of less than 1%. The contractor must adhere to CLSI standards for quality control and comply with OSHA, EPA, and 40 CFR regulations regarding hazardous waste documentation and safety data sheets. Equipment acceptance is contingent upon meeting performance standards for 30 consecutive calendar days at an effectiveness level of 90% or more. Award will be based on a comparative evaluation of past performance, price, and technical capability to determine the most advantageous offer to the government. The solicitation is open to all qualified offerors, with a specific price evaluation preference for HUBZone small business concerns. Submissions must include a price quotation and past performance information, with an optional technical section, and be delivered electronically to the contracting officer.
Analytical Laboratory Instrument Manufacturing

POSTED

2 days ago

DEADLINE

in 5 days
View Details
NAICS: 236220
New
Federal
Z1DA--NRM| 460-26-007 Electrical Distribution Inspection Repairs | NCO 4 Construction East (VA-26-00057558)
Solicitation # 36C24427B0002
The Department of Veterans Affairs Network Contracting Office 4 has issued a Request for Information for planning and market research purposes regarding electrical distribution inspection repairs at the Wilmington, Delaware VA Medical Center. This is not a request for proposal, and the government is not obligated to award a contract based on this notice. The project involves repairing all failures identified in the facility's electrical inspection and testing report, specifically focusing on the review and validation of results, the procurement and installation of circuit breakers and racking mechanisms, and the repair of old equipment to be used as future spares. All work must adhere to VA requirements, NETA test standards, and applicable federal, state, and local codes, with a total performance period of 365 days from the Notice to Proceed. The estimated magnitude of construction is between 25,000.00 and 100,000.00. This opportunity is designated as a set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 236220 for Commercial and Institutional Building Construction. Interested contractors must submit a statement of interest, capability statement, pricing for similar past projects, and company identification details, including their UEI number and intended contracting role, to the designated point of contact by October 30, 2026, at 4:00 PM EST. Submissions must be electronic, as hard copies will not be accepted.
Commercial and Institutional Building Construction

POSTED

5 days ago

DEADLINE

in 9 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS