Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on September 17, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

4-Ton HVAC Units

Closed
FA301626Q0270Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
WOJC - Multi-Building Plumbing Leak Repair Project
Solicitation # WOJC – Multi-Building Plumbing Leak Repair Project
Education and Training Resources is seeking quotes for a subcontracting opportunity to perform multi-building plumbing leak repairs at the Westover Job Corps Center in Chicopee, Massachusetts. The scope of work includes replacing leaking shower P-trap drain pipes in Rooms 123 and 213, repairing a cracked drain pipe in the pipe chase of Room 216, and replacing approximately ten linear feet of leaking heat pipe in both the Administration Building and King Hall. All work must comply with the Massachusetts State Plumbing Code, International Plumbing Code, and applicable federal, state, and local regulations. Contractors are responsible for all cutting, patching, and debris removal, ensuring that all materials used are new and of commercial quality. Interested bidders must submit a detailed quote by October 30, 2026, including a comprehensive cost breakdown of labor and materials, a proposed service schedule, and a bid valid for at least 60 days. Required documentation includes a current SAM.gov UEI number, active registration, W-9, business licenses, Massachusetts plumbing credentials, and certificates of liability insurance. The project is subject to various Federal Acquisition Regulation clauses, including the Davis-Bacon Act and Service Contract Act for prevailing wages, and requires the submission of weekly certified payroll reports. Award selection is at the sole discretion of ETR and is not based solely on the lowest bid. Performance and payment bonds are required for projects exceeding 35,000 dollars, with specific requirements increasing for projects over 150,000 dollars.
Westover Job Corps Center

POSTED

about 10 hours ago

DEADLINE

in 9 days

AI Contract Overview

Show more

Solicitation FA301626Q0270 is a small business set-aside request for quotation for the decommissioning, removal, disposal, and replacement of seven 4-ton Bard wall-mounted HVAC units or approved equals at Building 1472, JBSA Fort Sam Houston, Texas. The project supports mission-critical cooling for electrical panel, switchgear, and chiller plant control rooms. The scope of work includes a comprehensive site survey, EPA Section 608 compliant refrigerant recovery, and the installation of high-efficiency units with 460V 3-phase electrical service and R-32 or R-454B refrigerant. All technical work must be performed by master or journeyman HVAC technicians holding active state licenses and EPA Section 608 Universal Certifications. The contract will be awarded based on the Lowest Price Technically Acceptable (LPTA) approach, requiring offerors to provide specification cut sheets to prove the equipment meets all salient characteristics. Performance is requested by December 14, 2026, with a binding completion timeline of 90 calendar days after receipt of order. Final payment is contingent upon formal government acceptance via Wide Area Workflow (WAWF) and the submission of a signed-off closeout, training, and handover package. Base access requires valid REAL ID or passport documentation and a formal written request on company letterhead. The solicitation closing date was extended via Amendment 0002 to September 23, 2026, at 10:00 AM CST.

General Info

Small business HVAC replacement of seven units at JBSA Fort Sam Houston, Texas.

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance

0, TX, 78234, USA

Set-Aside

SBA

Documents

9

FA301626Q0270 - Replacement of Seven 4-Ton HVAC Units

PDF, High priority: read this firstrfq
High

FA301626Q0270 - Replacement of Seven 4-Ton HVAC Units

PDF, High priority: read this firstrfq
High

FA301626Q0270 RFQ - 7 HVAC Units Replacement

PDF, High priority: read this firstrfq
High

RFQ FA301626Q0270 - Responses to Questions

PDF, High priority: read this firstq-and-a
High

Salient Characteristics for Data Center CRAC & Chiller Replacement

PDF, High priority: read this firstspecifications
High

Salient Characteristics: Wall-Mounted HVAC Units

PDF, High priority: read this firstspecifications
High

SOW - Replacement of Seven 4-Ton Bard HVAC Units

PDF, High priority: read this firstsow
High

SOW - Replacement of Seven (7) Bard HVAC Units

PDF, High priority: read this firstsow
High

Pictures of HVAC Units

PDF, Low priorityspecifications
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

2 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

Response deadline changed from Sep 16, 2026 to Sep 18, 2026. The notice description changed.

Notice updated

Response deadline changed from Sep 18, 2026 to Sep 23, 2026. The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3016 502 Cons Cl
Contacts2 people available
OfficeJBSA LACKLAND, TX, 78236-5286, USA
Office AddressJBSA LACKLAND, TX, 78236-5286, USA

Full Description

Show more

Amendment 0002


The purpose of this Amendment is to incorporate the correct salient characteristics for the requirement and to extend the solicitation closing day to 23 September 2026 at 10:00AM CST. All other terms and conditions will remain the same.


_________________________________________________________________________


This is a combined synopsis/solicitation for commercial products prepared in accordance with part 12. This announcement constitutes the only solicitation. Offers are being requested and a separate written solicitation will not be issued.


Solicitation number FA301626Q0270 is issued as a request for quotation (RFQ) for seven (7) 4-ton Bard HVAC units or Equal to include decommissioning, removing, replacing and disposing.  Performance and delivery will be located at Building 1472, 3290 Corporal Johnson Rd, JBSA Fort Sam Houston, TX.


This acquisition is set-aside for small business concerns. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov.

More opportunities from Department Of Defense → FA3016 502 Cons Cl

Same awarding agency

NAICS: 238210
New
Federal
DCF3 PROJECTION SYSTEM
Solicitation # A070977
The Department of Defense, specifically the 502 Cons Cl under the Office of the Air Force, is issuing a sources-sought Request for Information (RFI) for the DCF3 Projection System, solicitation number A070977. The objective is to identify capable providers for the installation of standalone audio-visual (AV) classroom equipment in sixteen classrooms at the BMT DCF3 (Building 9270) located at JBSA-Lackland, Texas. The scope of work includes providing all personnel, equipment, and materials to install laser projectors, zoom lenses, lecterns, scaling switchers, and associated cabling. The system must operate as a standalone solution and is strictly prohibited from interfacing with the Air Force network. Key deliverables include the integration of Apple Government-Furnished Equipment, the provision of technical documentation, and the delivery of user training for staff. Technical requirements specify that projectors and extension columns must be Trade Agreement Act (TAA) compliant, and touch panels must be FCC Class A certified. The contractor is responsible for ensuring high video resolution and sound quality, with final acceptance based on a post-installation walkthrough and inspection at the project site. Security requirements are stringent, requiring criminal history checks and background investigations for all personnel accessing the base, as well as strict adherence to Force Protection Condition procedures and a total prohibition of weapons on site. This RFI is strictly voluntary and is not a formal solicitation for quotes; interested parties must submit their capabilities and open-market pricing via email to Tommie Low by October 27, 2026, at 10 a.m. CST.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details
NAICS: 238220
New
Federal
Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement
Solicitation # A070764SS
The 502d Contracting Squadron is conducting market research via a Sources Sought Synopsis to identify capable industry sources for the turnkey removal and replacement of 48 ceiling-suspended Dedicated Outside Air System Water-Source Heat Pumps at the JBSA Ft Sam Houston San Antonio Military Medical Center Dormitory Annex, specifically in buildings B3631 and B3635. The project is projected as a Firm-Fixed Priced Purchase Order under NAICS code 238220. The contractor must provide all personnel, equipment, and supervision to install units that meet strict technical specifications, including a 1.25-ton capacity, horizontal ceiling-plenum configuration, and the use of low-GWP refrigerants such as R-454B or R-32, as R-410A is strictly prohibited. A critical requirement is that replacement units must fit through existing access openings measuring approximately 3 feet 11.5 inches by 2 feet to avoid structural demolition. The scope of work includes the integration of the units into the central Building Automation System via BACnet IP/MSTP and the use of AHR/ISO 13256-1 certified water-to-refrigerant coaxial heat exchangers. Performance must be completed within 275 days of award. Interested respondents must provide company identification, SAM.gov certifications, and confirmation that technicians hold EPA Section 608 Universal Certifications. Small business prime contractors must also verify they can cover at least 51 percent of the contract cost with their own personnel. Responses are due by October 26, 2026, and must be submitted in PDF format with a maximum length of ten pages, excluding equipment cut sheets.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

6 days ago

DEADLINE

in 6 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS