Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on October 7, 2015. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

41-- CHILLER UNITS B31 & B211

Awarded
VA25015Q0462Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
DIBBS
AIR CONDITIONER
Solicitation # SPE8E8-27-T-0208
Solicitation SPE8E8-27-T-0208 is a request for quotations issued by DLA Troop Support Construction and Equipment for the procurement of three air conditioner units. The required hardware is identified by part number 640315CXX1C0 from Dometic Environmental Corp (DBA 4XB81) and NSN 4120017018393. The need ship date is April 12, 2027, with an original required delivery date of May 25, 2027. Delivery is set as FOB Origin, with inspection and acceptance occurring at the destination, specifically the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The contractor must adhere to strict packaging and marking standards, including MIL-STD-129 and ASTM D3951, with palletization following DLA requirement RP001. Technical and quality requirements are governed by the DLA Master List, including specific mandates for the removal of government identification from non-accepted supplies and source approval documentation. Payment and invoicing must be processed electronically through the Wide Area WorkFlow system. Compliance requirements include adherence to the Buy American Act, the Berry Amendment, and various DFARS regulations regarding cybersecurity, safeguarding covered defense information, and the prohibition of covered defense telecommunications equipment. Offerors must submit their quotes via the DLA Internet Bid Board System (DIBBS) under NAICS code 333415.
DDSP NEW CUMBERLAND FACILITY

POSTED

about 16 hours ago

DEADLINE

in 4 days
NAICS: 333415
New
Federal
NSWCCD York Chill Pump Replacement
Solicitation # N0016727Q1002
The Naval Surface Warfare Center, Carderock Division (NSWCCD) is soliciting quotes for the procurement, delivery, and turn-key installation of a replacement pump (Pump No. 1) for York Chiller No. 1 in Building 157. This equipment is critical for providing chilled-water cooling to the Building 13 Server Rooms. The project requires the removal of the damaged pump and the installation of a York Chill Pump, Model YLAA0080SJ46X, Serial SEMM-609950. Due to the proprietary nature of the equipment, the contractor must utilize certified Johnson Controls technicians or representatives. The installation must be completed on or before December 18, 2026, at the NSWCCD facility in Bethesda, Maryland. This is a brand-name restricted procurement under full and open competition and is not set aside for small businesses. The government intends to award a single firm-fixed-price purchase order based on the lowest price technically acceptable method, evaluating quotations on a pass/fail basis for technical requirements and considering past performance via the Supplier Performance Risk System. All quotes must be submitted on official company letterhead, including all-inclusive pricing and business size, and sent via email to the contract specialist and contracting officer by 09:00 AM EDT on November 06, 2026. The contract includes specific requirements for item unique identification per MIL-STD-130 and electronic invoicing through the Wide Area WorkFlow system.
Nswc Carderock

POSTED

about 21 hours ago

DEADLINE

in 17 days

AI Contract Overview

Show more

The Department of Veteran Affairs requires the procurement and installation of two new replacement air chillers for the VA Medical Center in Chillicothe, Ohio. The project involves providing a Trane RTAF-115 for Building 31 and a Trane RTAE-150 for Building 211, or approved equals that meet specific technical standards. Both units must feature variable speed screw compressors, as scroll compressors are strictly prohibited, and must be compatible with the existing Tridium-based JACE building automation system via a BACnet MS/TP interface. This contract is designated as a Service Disabled Veteran Owned Small Business set-aside. Requirements include full compliance with AHRI and ASHRAE 90.1 standards, ASME pressure vessel codes, and the provision of startup and training services. Warranty terms specify a first-year labor warranty for the whole unit and compressor parts coverage for the second through fifth years. All equipment must be delivered FOB Destination to the medical center.

General Info

Agency

N/A

Contract Value

$192,024

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

OH, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Combined Synopsis

Notice updated

Set-aside added: Service-Disabled Veteran-Owned Small Business Set Aside.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
STATEMENT OF WORK (SOW) The Department of Veteran Affairs VA Medical Center located in Chillicothe, OH, has a requirement for two (2) replacement Air Chillers (a Trane RTAF-115 and a Trane RTAE-150). The Chillers will be located at Bldg. 31 and Bldg. 211. This is a Service Disabled Veteran Owned Small Business (SDVOSB) set-aside. FOB: Destination (VA Medical Center, 17273 State Route 104, Chillicothe, OH 45601). New equipment only, all items must be quoted, brand name or equal. If submitting Equal, the provisions of clauses 52.212-2 and 852.211-73 must be followed exactly. Evaluation based on technically acceptable, compatible with existing system. Scroll compressors are not acceprtable. All responses must be submitted by email, to contact listed below, by noon Monday, September 28, 2015. See attached. Current building automation system is configured and uses Tridium based JACE controllers. For Bldg. 31: Trane RTAF-115 RTAF air-cooled screw chiller Unit startup 115 nominal tons 60 hertz 460V/60Hz/3 phase High efficiency Minimum efficiency at AHRI conditions Full Load: 10.0 EER Part Load: 15.8 EER UL listed to US and Canadian safety std ASME pressure vessel code Refrigerant charge R-134a AHRI certified ASHRAE 90.1 all versions compliant Standard cooling 2 pass evaporator Fluid type - propylene glycol Grooved pipe Factory installed flow switch fluid other than water - 15 cm/s Factory insulation-all cold parts 0.75 inch Wide ambient Microchannel coil Variable speed fans Oil cooler Variable speed screw compressors required for part load operation Single point power connection Circuit breaker Default amp short circuit rating BACnet MS/TP interface (Tracer compatible) Programmable relay 2nd-5th year compressor parts 1st year labor warranty whole unit Startup and training included Bldg. 211 Trane RTAE-150 Air-cooled Series R model RTAE 150 ton single circuit 200 volt 3 phases 60 Hertz Minimum efficiency at AHRI conditions Full Load: 10.7 EER Part Load: 19.7 EER UL listed to US and Canadian Safety Standard ASME pressure vessel code Refrigerant charge HFC-134a AHRI certified ASHRAE 90.1 - all versions compliant Standard cooling (40 to 65F/4.4 to 18C) 2 pass evaporator Factory installed flow switch - glycol fluid (15 cm/s) Factory insulation - all cold parts 0.75" Wide ambient (0 to 125F) Aluminum fins with slits Variable speed screw compressors required for part load operation Adaptive Frequency Drive 3rd generation Single point connection main line unit power-ancillary items require other power Circuit breaker high fault rated panel High amp short circuit rating 65,000 amps Factory installed transformer Line reactors (~30% TDD) BACnet MS/TP interface (Tracer compatible) Architectural louvered panels Elastomeric isolators 2nd-5th year compressor parts 1st year labor warranty whole unit Startup and training included

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS