This Sources Sought opportunity from Department Of Veterans Affairs was posted on August 13, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
4110--Helmer iPR245-GX i.Series Pharmaceutical Refrigerator (Brand Name or Equal)
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The Department of Veterans Affairs Manila Outpatient Clinic is conducting a market research effort to identify potential sources for two Helmer iPR245-GX i.Series Pharmacy Refrigerators or an equivalent model. These high-performance units must feature a 44.9 cubic foot capacity, a temperature range of +2C to +10C, and Energy Star certification. Key technical requirements include a VCC compressor-based refrigeration system, an i.C3 color touchscreen interface, and compliance with NSF/ANSI 456 vaccine storage standards. The equipment must also include comprehensive alarm systems, battery backup, and a certificate of calibration. This Sources Sought Notice is for planning purposes only and is not a formal solicitation. Interested vendors under NAICS code 333415 must submit their company details, capability statements, and estimated pricing to the contracting officer by August 19, 2026. No set-aside determination has been made at this time, and the government will not provide reimbursement for costs associated with responding to this notice.
General Info
Agency
NAICS
Place of Performance
Department of Veterans Affairs Manila Outpatient Clinic, Pasay City, CA, 1302, PHLSet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
This is a Sources Sought Notice issued solely for information and planning purposes ONLY. It does not constitute a solicitation. Responses to this notice will assist the Government in identifying potential sources capable of providing the required equipment. No reimbursement will be made for any costs associated with providing information in response to this notice.
The Department of Veterans Affairs, Manila Outpatient Clinic is seeking potential sources capable of providing two (2) units Helmer iPR245-GX i.Series® Pharmacy Refrigerator, 44.9 cu ft, (Brand name or Equal).
The essential/significant physical, functional or performance characteristics of the requirement are:
Application, Rating, & Electrical Data Application High performance storage of medical and scientific products Storage Volume 44.9 cu ft | 1271 L Temperature Range +2°C to +10°C Set Point +5°C Electrical Power 115V 60Hz | 220-240V 50-60Hz Certification/Agency Listing QPS (Certified to UL and CSA Standards) IEC/UL61010-2-011: 2016 | IEC 61010-1:2010, AMD1:2016 ETL certified to NSF/ANSI 456 Vaccine Storage Standard Energy Star Yes, ENERGY STAR® Certified High Performance Refrigerator Ambient Operating Temperature +15°C to +32°C | +59°F to +90°F Refrigeration Refrigeration System VCC compressor-based, forced-air hydrocarbon Compressor Hermetic, variable speed (VCC). Rated speed range: 1300-4000 rpm Condenser Type Air-cooled fin and tube, sealed Defrost Method Automatic Refrigerant R600a, Isobutane, EPA SNAP compliant Controller / Configuration Settings User Interface i.C3® color touchscreen, door mounted, 7in | 177mm, °C or °F Power Switch On/Off Controller Type Microprocessor with touchscreen input & display Security Lockable doors, password protected settings Control Sensor RTD, stainless steel iPR245-GX i.Series® Pharmacy Refrigerator, 44.9 cu ft (1271 Liters) (with NSF/ANSI 456 Vaccine Storage Certified Labeling and Certificate of Calibration
Communication Ports USB, Remote alarm contacts, RJ45 (Ethernet). API available for Ethernet connectivity development Power Failure Alarm Yes High/Low Alarms - Tests Yes, fully adjustable, automatic (Peltier) testing Door Ajar Alarm Yes, fully adjustable Condenser Temperature Alarm Yes, fully adjustable Min/Max Temperature Yes, display and reset Download Yes, via USB. CSV and PDF Event Log Yes, all alarms, door openings, download via USB Temperature Log Yes, download via USB Interactive Temperature Graph Yes Temperature Monitoring Ballast Yes, two 4 oz bottles with screw caps, solid ballasts optional Battery Back-up Yes, 20 hr. display & alarm back up for i.C3® touchscreen | Rechargeable 12V, lead acid Interior Storage (w x h x d) 2 ventilated, powder coated shelves, adjustable 22.5 x 21.9 in | 572 x 557 mm, 100 lb | 46 kg max capacity/shelf 12 ventilated, powder coated, pull-out drawers, adjustable 21.5 x 3.9 x 22 in | 546 x 100 x 560 mm, 100 lb | 46 kg max capacity/drawer iPR245-GX i.Series® Pharmacy Refrigerator, 44.9 cu ft (1271 Liters) (with NSF/ANSI 456 Vaccine Storage Certified Labeling and Certificate of Calibration
Options | Accessories Stainless steel interior, Chart recorder, Chart paper, Leveling feet, Solid ballast, Remote alarms, Floor and Wall bracket kit, Seismic anchoring kit, Storage trays, Screen protector, Locking drawer, Solid or heated glass doors, Top cover, Side-wall access ports, Temperature validation, Validation guide (IQ/OQ), Extended warranty Certificate of Calibration Yes, generated with ISO 17025 certified, NIST traceable thermometer Warranty Rel.i Plus Warranty - 7 years compressor, 2 years parts, 1 year labor Outside US and Canada - Contact your distributor for warranty information
The anticipated NAICS code for this requirement is 333415 Air-Conditioning and warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing with Size Standard of 1,250 employees.
No set-aside determination has been made at this time. The Government is seeking information to support acquisition planning and any applicable socioeconomic determination.
Only firms interested and capable should send their information and any questions by email to Cristina.lansangan@va.gov no later than 4:00 PM Pacific Standard Time, August 19, 2026.
Please provide the following information in your response: Company Name and UEI Point of Contact: Name, Phone Number and E-mail address SBA Socio-economic Status Capability Statement Indicate whether this equipment is available under GSA/FSS/NAC contract, including contract number and expiry date Authorized Distributor Letter (if applicable) Estimated Price
DISCLAIMER
This Sources Sought notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request that is marked proprietary will be handled accordingly. The Government will not compensate an offeror for providing information in response to this notice. Furthermore, the Government reserves the right to cancel this requirement at its discretion.
More opportunities from Department Of Veterans Affairs → 261-NETWORK Contract Office 21 (36C261)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS