Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on September 3, 2021. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

4120--GREEN Procure Chilled Water Coils (VA-21-00089637) Last Updated: 8/15/2021 Type: SPECIAL

Closed
36C24221Q1437Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
DIBBS
AIR CONDITIONER
Solicitation # SPE8E8-27-T-0208
Solicitation SPE8E8-27-T-0208 is a request for quotations issued by DLA Troop Support Construction and Equipment for the procurement of three air conditioner units. The required hardware is identified by part number 640315CXX1C0 from Dometic Environmental Corp (DBA 4XB81) and NSN 4120017018393. The need ship date is April 12, 2027, with an original required delivery date of May 25, 2027. Delivery is set as FOB Origin, with inspection and acceptance occurring at the destination, specifically the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The contractor must adhere to strict packaging and marking standards, including MIL-STD-129 and ASTM D3951, with palletization following DLA requirement RP001. Technical and quality requirements are governed by the DLA Master List, including specific mandates for the removal of government identification from non-accepted supplies and source approval documentation. Payment and invoicing must be processed electronically through the Wide Area WorkFlow system. Compliance requirements include adherence to the Buy American Act, the Berry Amendment, and various DFARS regulations regarding cybersecurity, safeguarding covered defense information, and the prohibition of covered defense telecommunications equipment. Offerors must submit their quotes via the DLA Internet Bid Board System (DIBBS) under NAICS code 333415.
DDSP NEW CUMBERLAND FACILITY

POSTED

about 11 hours ago

DEADLINE

in 5 days
NAICS: 333415
New
Federal
NSWCCD York Chill Pump Replacement
Solicitation # N0016727Q1002
The Naval Surface Warfare Center, Carderock Division (NSWCCD) is soliciting quotes for the procurement, delivery, and turn-key installation of a replacement pump (Pump No. 1) for York Chiller No. 1 in Building 157. This equipment is critical for providing chilled-water cooling to the Building 13 Server Rooms. The project requires the removal of the damaged pump and the installation of a York Chill Pump, Model YLAA0080SJ46X, Serial SEMM-609950. Due to the proprietary nature of the equipment, the contractor must utilize certified Johnson Controls technicians or representatives. The installation must be completed on or before December 18, 2026, at the NSWCCD facility in Bethesda, Maryland. This is a brand-name restricted procurement under full and open competition and is not set aside for small businesses. The government intends to award a single firm-fixed-price purchase order based on the lowest price technically acceptable method, evaluating quotations on a pass/fail basis for technical requirements and considering past performance via the Supplier Performance Risk System. All quotes must be submitted on official company letterhead, including all-inclusive pricing and business size, and sent via email to the contract specialist and contracting officer by 09:00 AM EDT on November 06, 2026. The contract includes specific requirements for item unique identification per MIL-STD-130 and electronic invoicing through the Wide Area WorkFlow system.
Nswc Carderock

POSTED

about 16 hours ago

DEADLINE

in 17 days

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

NY

Set-Aside

NONE

Documents

1

36C24221Q1437.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Lateisha RobinsonContract Specialist

Full Description

Show more
Please note that this is NOT a request for quotes or proposals, the Government is seeking information for market research purposes only. VHA Reginal Procurement Office (RPO) 2 is currently conducting a market survey for qualified firms capable of providing Chilled water coils. The North American Industry Classification Systems (NAICS) is 333415. Responses to this notice must be submitted in writing (email or fax) and must be received no later than September 9 ,2021. @ 10AM EST. Email: contact@example.gov and Fax: +1 (555) 000-0000. No telephone inquiries will be accepted. Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, DUNS number and address, point of contact and social-economic. Interested parties who do not submit the above information on or before the response due date and time will not be considered for this procurement. Please review the attached Statement of Work attached herein. STATEMENT OF WORK A. GENERAL INFORMATION 1. Title of Project: Fabrication and delivery of four (4) Chilled Water Coils for Air Handler Unit (AHU) No. s 1 and 4 located in Building 200N at the Northport VA Medical Center, 79 Middleville Road, Northport NY 11768. 2. Scope of Work: Procurement of two (2) chilled water coils with the following specifications: Type W Tube Size and circuitry: 12Z Dims: 32.5X113 Rows: 6 FPI: 10-R or L Coil: R Copper tube 0.5000 x 0.0160 Aluminum Fin 0.0060 Galvanized casing 16-gauge Estimated weight 578 lbs. each Procurement of two (2) chilled water coils with the following specifications: Type W Tube Size and circuitry: 12Z Dims: 30X113 Rows: 6 FPI: 10-R or L Coil: R Copper tube 0.5000 x 0.0160 Aluminum Fin 0.0060 Galvanized casing 16-gauge Estimated weight 540 lbs. each 3. Background: AHU No. s 1 and 4 provide service to Building 200N. The existing chilled water coils, located in AHU No. 1 and 4, are worn, leaking and are irreparable. The existing coils are required to be replaced so that AHU No. s 1 and 4 can continue to operate properly. 4. Performance Period: 2 days from date of award 5. Place of Performance: Northport VAMC, 79 Middleville Road, Northport NY 11768 6. Type of Contract: Firm fixed price. B. CONTRACTOR PERSONNEL SECURITY REQUIREMENTS 1. The contractor shall not have access to the Department of Veterans Affairs computer systems. The certification and accreditation (C&A) requirements do not apply and a Security Accreditation Package is not required.

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS