4610--Engineering Request - SPS REVERSE OSMOSIS | 538-26-3-6064-0049 (VA-26-00079545) - VAMC Chillicothe
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
Solicitation 36C25026Q1034 is a 100% small business set-aside request for quotation issued by the Department of Veterans Affairs Network Contracting Office 10. The project involves providing equipment to replace end-of-life and undersized sterile processing water equipment at the Chillicothe VAMC to comply with ANSI/AAMI ST108:2023 water safety mandates. The scope of work includes the provision of Reverse Osmosis systems, including one unit with a minimum of 15,000 to 20,000 GPD and 95% NACL percent rejection, as well as filter housings, UV lights, and drain tanks. All equipment must be delivered to the Chillicothe VAMC Building 23 Warehouse. Notably, the installation and testing of equipment, as well as the provision of pumps and tank vent cartridges, are explicitly excluded from the scope. The contract is awarded based on a comparative evaluation where technical capabilities and past performance are weighted more heavily than price. The period of performance is 90 days from the date of award, and the contractor must submit specification documentation to the COR for review prior to purchasing equipment. Deliveries must be marked FAST PAY, and the contractor is required to provide operations and maintenance manuals and cutsheets for review prior to acceptance. The response deadline for this procurement is September 22, 2026, at 3:00 PM Eastern Time.
General Info
Contract Value
$64,400Place of Performance
Department of Veterans Affairs Chillicothe VAMC, Chillicothe, OH, 45601, USASet-Aside
Award Issued Date
Timeline
Submission Closed
Organization & Contact Information
Full Description
Are the 0.2 Micron Filter Cartridges the ones that are for the tank vent filter we would be providing? Or is this for an existing endotoxin filter housing the facility has? 0.2 Micron Filter Cartridges are for bacterial removal from water and to be compatible with housing provided under CLIN 0003. Tank vent cartridges are maintained separately and not within scope. What flow rates do the 60-gallon and 160-gallon storage tank loop return need to handle? Specifically, when sizing the loop return flow meter we need to ensure it can handle the pump demand. I would assume 20 GPM and 40 GPM based on the UV assembly? Return is being constrained via 3gpm flow control device. Pumps are pressure sensing variable flow rate. Both flow control and pumps are not within scope of the solicitation. UV sized for peak demand. Are there existing pumps within the facility that they are keeping? I do not see a distribution pump mentioned in this bid. Pumps are not within scope. Do you have a list of existing equipment that is being kept for both systems? No What are the distribution loop sizes, loop material and loop length are they existing or is this a new loop? Modifying existing loop. Mixed materials, CPVC and Polypropylene. Loop is approximately 240 LF with mixed sizes of 1 and 1-1/2
More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS