Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on June 7, 2019. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

65--Endoscopy Carts & Equipment for the Edward Hines Jr. VAH located in Hines, Illinois.

Awarded
36C25219Q0370Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources-sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefit from their devices. The requirement includes the provision of equipment with advanced technical specifications, such as dual ear capability, a frequency range of 200 to 16,000 Hz, and a comprehensive test suite including speechmap counseling and pediatric probe tube placement. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

1 day ago

DEADLINE

in 5 days
NAICS: 334510
New
Federal
6515--ForeSite SS Tablet w/Pressure Mapping Sensor System
Solicitation # 36C24827Q0082
The Department of Veterans Affairs, through Network Contracting Office 8, is conducting market research via a Sources Sought Notice to identify authorized sources for the ForeSite SS Tablet Pressure Mapping System manufactured by ForeSite Medical. This effort is for acquisition planning purposes and is not a formal solicitation. The required system is intended for clinical pressure assessment and treatment and must include the tablet platform, pressure-mapping sensors, sensor packs, chargers, software licenses, cables, and all necessary accessories. Key functional requirements include real-time pressure analysis and visualization, patient data storage and reporting, wireless and wired connectivity, and portable battery-powered operation. All equipment must be new and include the manufacturer's standard warranty. Interested vendors must submit electronic responses in PDF or Word format by October 30, 2026. Submissions must include the company name, address, Unique Entity Identifier, point of contact, and business size or socioeconomic status, such as SDVOSB, VOSB, Small Business, or Large Business. Additionally, respondents must provide documentation proving they are authorized to distribute or resell the ForeSite system, an estimated delivery lead time, and confirmation regarding the new condition and warranty of the product. The place of performance is located in Tampa, Florida, under NAICS code 334510.
248-NETWORK Contract Office 8 (36C248)

POSTED

3 days ago

DEADLINE

in about 12 hours
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

3 days ago

DEADLINE

in 14 days

General Info

Contract Value

$599,337.67

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

WI

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

2 updates
PhaseAwarded
Posted

Sources Sought

Notice updated

Notice type changed from Sources Sought to Special Notice. The response deadline was removed. The notice title changed. NAICS code changed from 339112 to 334510. The notice description changed.

Notice updated

Notice type changed from Special Notice to Presolicitation. Response deadline added: May 10, 2019. The notice title changed. The notice description changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)
ContactsNo contacts available
OfficeMILWAUKEE, WI, 53214, USA
Office AddressMILWAUKEE, WI, 53214, USA
ContactsNo contact information available

Full Description

Show more
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Endoscopy Carts & Equipment, KARL STORZ brand name or equal, for the Edward Hines Jr. VAH in Hines, Illinois. General Requirements: BRAND NAME (KARL STORZ) OR EQUAL: The Endoscopy Carts & Equipment shall include at a minimum the following characteristics. Office Cart: - Not to exceed the following dimensions: 40.5 H x 24.5 W x 20.3 D. - Shall include isolation transformer to protect video electronics. - Shall have shelves that provide three (3) total interior placement surfaces. - Shall include monitor tilt at 15° up / 30° down to allow for better viewing due to surgeon and resident height. - Shall include monitor pan tilt at + /- 45°. Surgical Video Camera System: - Shall be modular in design with separate modules that include HD, 4K, 3D and ICG to work with both rigid and flexible endoscopes to allow users to extend the life of the equipment, while providing the ability to upgrade in the future to new technology without having to buy a new video setup. - Shall have expandability with capability of backward and forward movement. - Shall be compatible with existing camera heads, Karl Storz Image 1 CCU (Camera Control Unit) & Karl Storz Image 1 Camera Head. - Shall have enhancement built in to identify and brighten up dark areas in real time without overexposing the bright part of the image. - The enhancement increases the visibility and vascularity of blood vessels that minimizes the likelihood of injuring delicate ENT procedures. - Shall have enhancement built in to eliminate dark areas in an image in real time. - The enhancement allows the surgeon to keep their telescope in the right distance from the surgical target and being able to effectively perceive and discern additional content. - Shall have Pointer Visualization overlay to facilitate effective verbal communication between the attending surgeon and residents. - Shall have Grid Visualization overlay that facilitates effective verbal communication between the attending surgeon and residents. - Shall have screen saver for burn-in protection to product the technology from burn out. - Shall have Dashboard with warnings and information application. - Shall have PIP (Picture-in-Picture) so users can help patients understand the diagnosis. - Shall have at least twenty (20) presets on the dashboard that can be stored, deleted, saved to a USB device and allow each surgeon and resident to have their own preferences when using the technology. 26 LED Monitor: - Shall have 1920 x 1080 resolution. - Shall have aspect ratio of 16:9. - Shall have LED backlit. - Shall have the following input/outputs: 1) DVI-D. 2) 3G HD-SDI (BNC tri mode). 3) RGB/YPbPr (D-sub 15 pin). 4) S-video (4 pin mini DIN). 5) Video (Composite BNC). 6) RGB/VGA: 1 input. 7) Shall be able to toggle between side-by-side and picture in picture images. 8) Shall include surgical video and radiology graphics imaging and 178° wide angle viewing. LED 175W Light Source: - Shall have light bulb life of 30,000 plus hours. - Shall be LED only and not more than 175W allowing users to have the optimal amount of illumination without overheating or burning the distal tip of the endoscope or the patient. - Any higher wattage might cause the scope to overheat and burn the patient and, could potentially burnout the distal end of the scope. - Shall be able to be integrated with Camera System connectivity for on-screen display and provides true light source control from the camera head and adjust while in the patient cavity. - Shall be environmentally friendly with no mercury or lead. HD Camera Head: - Shall have a grid and pointer surgical code. - Shall have an Optical Par Focal and Digital Zoom at 0.5x increments to 2.5. - Shall have image flip, rotate, vertical, horizontal, 180-degree capabilities. - Shall have image freeze/capture capabilities. - Shall have three (3) programming buttons on the camera head. - Shall be able to control picture in picture from CCU to camera head. - Shall be able to display two camera images side by side (Picture-in-picture [PiP]) functionality allowing two Link Modules to operate at the same time to include two images (two camera heads, one camera head and one video scope or two video scopes.) can be displayed and image captured in any PiP display mode. Adult Distal Chip Video Flexible Video Scope: - Shall have distal tip deflection of 140/140 degrees up/down for full cavity visualization. - Shall be a 0-degree direction of view and 85-degree angle of view: with 8-50 mm depth field for complete cavity visualization. - Shall have a working length of 30 cm, with an outer diameter of 3.7mm for complete cavity visualization and patient comfort. - Scope shall be able to connect video system with full image display. - Shall include integrated illumination bundle. Pediatric CMOS Video Flexible Scope: - For complete cavity visualization the scope shall have a direction of view of 0-degree, a field of view of 90-degrees, a depth of field of 4-50 mm with distal tip deflection of 270/270 degrees up/down. - For patient comfort the scope shall have an outer diameter of 2.9 mm with a working channel of 1.2 mm and a working length of 35 cm while having a total length not to exceed 65 cm. - Shall include integrated illumination bundle. - Scope shall must be able to connect to the video system and provide an octagonal shaped image for a more precise full view of the vocal chords and surrounding tissue. This allows users to see the full function of the vocal chords while examining younger patients. Video Distal Chip Flexible Scope with Working Channel: - For a complete cavity visualization and for optimal surgical functionality the scope shall have a direction of view: 0-degrees, a field of view of 90-degrees, a depth of field of 3 50 mm with distal tip deflection of 210-degrees upward and 140-degrees downward. - For patient comfort the scope shall have an outer diameter of 5.3 mm with a working channel of 2.2 mm and a working length of 37 cm while having a total length not to exceed and, at minimum 70 cm. - Shall include illumination bundle. - This allows for the T&E procedure in the clinic versus the need to go to the OR. - Shall be able to connect to video system with full image display. Patient Storage Device: - Shall be a storage device to backup all patient files that allows for 1-Terabyte in storage. - Shall include a video on demand solution via a web browser that is secured to all patient visit images. It shall allow surgeons access to images and/or video securely through a web browser and, secures access using LDAP/AD authentication to all images and/or video. - Shall have the ability to connect to the patient portal system (VistA) for records. Allows for viewing before and after examining patients to make comparative diagnosis and, allows users to have other peer evaluations for best practices. - Storage device shall allow for expansion into the OR and other clinic modules without the requirement of additional hardware and security deployment costs for lower future costs. - Shall be able to allow surgeons to access. - This will improve clinical workflow by eliminating manual workflow processes. - This will also eliminate unsecure media storage such as USB, DVD and CDs. - This shall secure patient examination based images with encryption and LDAP/AD access. - Shall support internal audit logs, and Fair warning. - Fair warning is a cross-platform healthcare privacy auditing for electronic health records. - Trade-in value for one (1) KARL STORZ Tower and twenty (20) KARL STORZ Flexible Rhino-Laryngoscopes Model 11101RP2. (Indicate in response if able to provide trade-in value.) All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. DUNS number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer. Submit responses to the Contracting Officer, Thomas Chesak, at contact@example.gov no later than 10:00 a.m. (Central Standard Time), 19 February 2019. 36C25219Q0370 Endoscopy Carts & Equipment for Hines VAH shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. The NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.

More opportunities from Department Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS