Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on February 4, 2019. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

65-- Iridex IQ 532 laser system and IQ 577 laser system

Awarded
36C26019Q0188Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 339115
New
Federal
N065--Slit Lamp Installation for the Captain James A. Lovell Federal Health Care Center (FHCC), located at 3001 Green Bay Rd., North Chicago, IL 60064.
Solicitation # 36C25227Q0055
Solicitation 36C25227Q0055 is a firm fixed price request for professional installation services for nine slit lamps in the optometry department at the Captain James A. Lovell Federal Health Care Center in North Chicago, Illinois. The scope of work requires the contractor to relocate the equipment from a non-climate-controlled warehouse to designated clinic rooms and perform assembly, mounting, alignment, and functional checks to ensure clinical readiness. All work must be completed within 60 days of the contract award and must adhere to manufacturer specifications from Haag-Streit/Reliance, as well as OSHA, FHCC safety, and infection control standards. Key deliverables include fully operational equipment, verification of calibration, installation reports, and manufacturer documentation. This opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 339115. The government will award the contract to the responsible offeror providing the most advantageous offer based on a comparative evaluation of price, technical requirements, and relevant experience. Invoicing must be submitted electronically via the Tungsten Network, with payments made in arrears through Electronic Funds Transfer. Offerors are required to provide a complete quote including the SF 1449, UEI, and SAM registration, while ensuring compliance with the Resource Conservation and Recovery Act for the disposal of all associated materials.
252-NETWORK Contract Office 12 (36C252)

POSTED

4 days ago

DEADLINE

in 15 days
NAICS: 339115
New
Federal
Invitation for Bids - Vision Correction Assembly
Solicitation # W912CH26BA014
The Army Contracting Command - Detroit Arsenal is soliciting bids for a five-year, Firm-Fixed-Price, Indefinite Delivery/Indefinite Quantity (IDIQ) contract for the manufacture and delivery of the Vision Correction Assembly, identified by NSN 4240-01-631-8044 and Part Number 5-1-4208. This non-commercial requirement involves production based on a Government-owned Technical Data Package (TDP) with Distribution Statement D export controls, requiring offerors to have a valid DD Form 2345 certification. The contract includes a guaranteed five-year minimum quantity of 30,690 units, with a maximum estimated quantity of 1,216,196 units. Key performance requirements include First Article Testing of 200 units, Production Lot Testing, and adherence to ISO 9001:2015 quality standards. The government intends to award a single contract to the responsible bidder offering the lowest total price, evaluated across five ordering years and a First Article Test Report. Bids must be submitted electronically by November 13, 2026, with a virtual bid opening scheduled for November 18, 2026. Deliveries are designated as FOB Destination to the Blue Grass Army Depot in Kentucky. Contractors are required to utilize the Wide Area WorkFlow system for invoicing and must comply with strict packaging and marking standards, including MIL-STD-129 and MIL-STD-2073-1. Access to the TDP may further require a Use and Non-Disclosure Agreement.
W6QK Acc- Dta

POSTED

7 days ago

DEADLINE

in 15 days
NAICS: 339115
Federal
Corneal Analyzer OPD-Scan III Wavefront Aberrometer
Solicitation # 36C24W27Q0010
The Department of Veterans Affairs Veterans Health Administration is conducting market research via a Sources Sought Notice for the procurement of one OPD-Scan III Visual System Wavefront Aberrometer/Corneal Analyzer for the San Francisco VA Health Care System in Oakland, California. This is a brand name or equal requirement, meaning the government will accept the specified Marco system or a functionally equivalent product that meets all salient physical and performance characteristics. The system must provide combined functionality for auto-refraction, auto-keratometry, topography, aberrometry, and pupillometry, with a spherical power range of -20.00 to +22.00 D and cylindrical power of 0.00 to ±12.00 D. It must also be compatible with Marco TRS-6100/5100 and NIDEK RT-6100 automated refraction systems. The final contract will be a Firm Fixed Price award requiring a minimum one-year manufacturer warranty. To prevent the acquisition of gray market items, the vendor must be an original equipment manufacturer or an authorized dealer/distributor, providing an authorization letter to verify that OEM warranty and service are maintained. Delivery is set as FOB Destination to the Oakland facility, with a specific constraint that items cannot be delivered before February 10, 2027. All deliveries must occur during normal business hours (0800 to 1500 PST) and be coordinated one week in advance. The Buy American Statute applies to this procurement. This current notice is for planning and size determination purposes only and does not constitute a solicitation or a binding offer.
Rpo West (36C24W)

POSTED

10 days ago

DEADLINE

in 5 days

General Info

Agency

N/A

Contract Value

$164,732

NAICS

339115 - Ophthalmic Goods Manufacturing

Place of Performance

Not specified

Set-Aside

NONE

Awardee

JILSAF LLC

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Presolicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
In accordance with FAR 13.106-1 (c )(1), the Department of Veterans Affairs intends to perform oral solicitations for 1 EA Iridex IQ 577 laser system and 1 EA Iridex IQ 532 laser system. This will be set-aside for SDVOSB s. To be considered eligible for award all SDVOSB s must be registered/verified through Vetbiz.gov. If you wish to be included in this solicitation, please respond electronically to contact@example.gov by 5 PM PST Monday January 21st 2019. This solicitation will be performed on Tuesday January 22nd. This will be a brand name or equal to solicitation to the following Items Manufactured by Iridex: Item Part Number Description Qty 9770600 Site~Rite 8r Ultrasound System Console (9770600), System includes: Console only (no probe), one year warranty, console, power supply, line cord, and electronic IFU. 4 9770131 Sherlock 3CGT Tip Confirmation System (9770131)This part number includes the sensor ONLY 4 9770116 Medical Equipment Roll Stand (MER) (9770116) Order 9770109 for laptop style ultrasound systems 4 9770508 SHERLOCK 3CGT Diamond TCS Activation Key for the Site~Riter 8 Ultrasound System (9770508) Software Key 4 9770509 DICOM / Connectivity Software for the Site~Riter 8 Ultrasound System - Activation Key (9770509) Connectivity (DICOM Send/ Store) 4 MW260MFIC129 BrotherT MW-260 Printer (MW260MFIC129) Requires 9770108 for use with MER Roll Stand. Mounting hardware not included. 4 9770517 Site~Riter Keyboard (9770517) Keyboard 4 9770602 Site~Rite 8r 20mm Pinpoint GT Probe (9770602) 20mm Pinpoint GT Probe for the Site~Rite 8r Ultrasound System 4 Shipping Address: Seattle VA Medical Center 1660 SOUTH COLUMBIAN WAY Seattle, WA 98108 To be considered technically acceptable, the products must meet the following minimum salient characteristics: Must meet minimum salient characteristics to be technically acceptable: The Iridex IQ 532 laser system is a green laser with micropulse technology that is used for retinal and glaucoma laserprocedures. Salient Characteristics 532 nm wavelength Can deliver up to 2500 mW of laser power High speed with pulse durations from 10 to 3000 ms Dual port for simultaneous connectivity of laser delivery devices Must have Wireless Footswitch Must have micropulse technology which breaks up the continuous wave beam into short pulses; adjustable duty cycles from 0.4% to 50% and preset selections of 5%, 10%, 15% duty cycles. Must have Laser indirect ophthalmoscopy option Must have wheelchair table Must have slit lamp that can mount to TxCell laser Must have beamsplitter and co-observer tube Must have safety glasses Must have multi-spot pattern scanning for pan retinal photocoagulation such as 2x2; 7 x 7 grid, circle and triple arc. Must have target grid Must have single spot mode and multisport patter mode Must have standard photocoagulation settings, fovea-friendly micropulse laser therapy for retinal diseases and micropulse laser trabeculoplasty for repeatable glaucoma TxCell must be in Haag-Streit Style configuration for slit lamp Must have voice confirmation of power settings The Iridex IQ 577 laser system is a yellow laser with micropulse technology that is used for retinal and glaucoma laser procedures. The 577nm allows for peak absorption in oxygenated hemoglobin. Salient Characteristics 577nm wavelength allows for peak absorption in oxygenated hemoglobin and dense ocular media and lower transmission to deeper tissues. High speed with pulse durations from 10 to 3000 ms Dual port for simultaneous connectivity of laser delivery devices Must have Wireless Footswitch Must have micropulse technology which breaks up the continuous wave beam into short pulses; adjustable duty cycles from 0.4% to 50% and preset selections of 5%, 10%, 15% duty cycles. Must have Laser indirect ophthalmoscopy option Must have wheelchair table Must have slit lamp that can mount to TxCell laser Must have beamsplitter and co-observer tube Must have safety glasses Must have multi-spot pattern scanning for pan retinal photocoagulation such as 2x2; 7 x 7 grid, circle and triple arc. Must have target grid Must have single spot mode and multisport patter mode Must have standard photocoagulation settings, fovea-friendly micropulse laser therapy for retinal diseases and micropulse laser trabeculoplasty for repeatable glaucoma TxCell must be in Haag-Streit Style configuration for slit lamp Must have voice confirmation of power settings 339115 Vendor shall be an Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system such that OEM warranty and service are provided and maintained by the OEM. All software licensing, warranty, and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. This procurement is for new Equipment ONLY; no remanufactured or "gray market" items. All Equipment must be covered by the manufacturer's warranty. (a) Gray market items are Original Equipment Manufacturer s (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts) for VA Medical Centers. No remanufactures or gray market items will be acceptable. (b) Vendor shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed medical supplies, medical equipment and/or services contracts for maintenance of medical equipment (i.e. replacement parts), verified by an authorization letter or other documents from the OEM, such that the OEM s warranty and service are provided and maintained by the OEM. All software licensing, warranty and service associated with the medical supplies, medical equipment and/or services contracts for maintenance of medical equipment shall be in accordance with the OEM terms and conditions. (c) The delivery of gray market items to the VA in the fulfillment of an order/award constitutes a breach of contract. Accordingly, the VA reserves the right enforce any of its contractual remedies. This includes termination of the contract or, solely at the VA s election, allowing the Vendor to replace, at no cost to the Government, any remanufactured or gray market item(s) delivered to a VA medical facility upon discovery of such items. *This notice satisfies the requirement at FAR 5.201 to synopsize proposed contract actions.*

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS