Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on August 17, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

65--Sources Sought Notice - Eye Clinic Diagnostic Equipment, VA St. Louis Health Care System, Jefferson Barracks Division Bldg. 55, St. Louis, MO

Closed
VA25517N0929Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

VHA Network 15 is conducting market research to identify potential manufacturing sources for specialized eye clinic diagnostic equipment for the VA St. Louis Health Care System. This Sources Sought notice aims to determine if the requirement can be competitively set aside for Service-Disabled Veteran-Owned or Veteran-Owned Small Businesses under NAICS code 333314. This is not a solicitation for proposals, and no funds are currently available for award. The required equipment includes an Optical Biometry Device, Visual Field Analyzer, Ocular Coherence Tomography Unit, Fundus Imaging Camera System, and a Corneal Topographer, specifically referencing Zeiss products. Additionally, a FORUM Data Management System with associated licenses and interfaces is required. Interested parties must submit their business details, small business status, and an OEM licensee agreement by August 23, 2017, to certify their authorization to manufacture the specified equipment.

General Info

Market research for specialized eye clinic diagnostic equipment for VA St. Louis Health Care.

NAICS

333314 - Optical Instrument and Lens Manufacturing

Place of Performance

VA St. Louis Health Care System;Jefferson Barracks Division, Clinic Bldg. 55;#1 Jefferson Barracks Drive;St. Louis, MO 63125-41, KS

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
ContactsNo contacts available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
ContactsNo contact information available

Full Description

Show more
This Sources Sought notice is in support of Market Research being conducted by VHA Network 15 Contracting to identify potential manufacturing sources and to determine if this effort can be competitive as a Service-Disabled, Veteran-Owned Small Business or Veteran-Owned, Small Business Set-Aside. This is not a Request for Proposal (or solicitation) or an indication that a contractual commitment will exist for this requirement. The government does not intend to award a contract based on this market research. No funds are available to fund the information solicited/provided. The proposed North American Industry Classification Systems (NAICS) Code is 333314 (Optical Instruments and Lens Manufacturing), with a corresponding Size Standard of 500 employees. The government requests that interested parties respond to this notice if applicable and identify your small business status to the identified NAICS code. The government requests that interested parties respond to this notice in writing including details of your ability to either provide a copy of OEM licensee agreement certifying your business is approved by the OEM to manufacture this equipment. The closing date for this sources sought notice is August 23, 2017, 10:00 a.m. Proprietary information, if any, should be minimized and MUST BE CLEARLY MARKED. Please be advised that all submissions become Government property and will not be returned The specific requirement for this effort is as listed below: Optical Biometry Device (Zeiss Product #266002-1162-219-PRO) Characteristics & Features: Uses Swept Source OCT Provides Full-length OCT image of showing anatomical details of the Eye Ability to recognize unusual eye geometrics of the eye, such as tilt or decentration of the crystalline lens. Telecentric Optics regardless of tech, the captured scan will be 100% in Focus Axial length from 14-38mm Ability to visualize Fixation from the Foveal Pit, or disease pathologies in the Foveal pit Automatic integration with Holladay 2 Formula VistA approved DICOM Modality Interface, FORUM interface Light Source wavelength of 780NM and composite signal for Cataract Penetration All In one biometer: Axial Length, Keratometry Measurements, White to White Measurements, as well as IOL Power Calculation in one device Accuracy to within +-0.02 mm or +- 0.05 D** (Ascan: .10 mm - .12 mm) Installation & Training: Vendor shall provide all necessary training and installation to bring the equipment to a fully functioning state Visual Field Analyzer (Zeiss Product 26602-1145-773-PRO) Characteristics & Features: System to have the ability of using liquid pressure to deliver each patient s refractive correction Touch screen interface Color graphics Gaze tracking initialization Kinetic graphical user interface with 180° testing range System must be able to review quantitative and qualitative information from all standard HFA analyses Must be able to change baselines and capture, track, and measure progression of Glaucoma Ability to preserve an image of the patient s eye at every stimulus presented during a standard test Must be able to check for ptosis or trial lens rim artifacts System to be able to generate reports of progression and compliance Visual field testing distance of 30 cm Maximum temporal range of 90° System Requirements: System hard drive to be at least 500 GB Printer included Dimensions of system to be no larger than 23 H x 20 W x 18 D Standards to follow UL, CSA, and CE Windows 7 OS Software Features: Single field analysis Glaucoma hemifield test Visual field index Guided progression analysis Serial field overview FORUM and DICOM connectivity options General Testing Features: Stimulus sizes Foveal threshold testing Automatic pupil measurement Auto liquid trail lens Stimulus Options White on white Red or blue on white Blue on yellow Fixation Control Blind spot monitor Video eye monitor Gaze tracking Head tracking Vertex monitoring Installation & Training: Vendor shall provide all necessary training and installation to bring the equipment to a fully functioning state Ocular Coherence Tomography Unit (Zeiss Product #266002-1161-980-PRO) Characteristics & Features System must have the ability to capture and provide OCT Angiography Ability is provided by one single OCT scan that allows for visualization of both micro vascular and structural information in an non-invasive dye free scan by the OCT Must have the ability to import and integrate raw data from the Cirrus Model HD OCT 4000. Exact Macular Scan Pattern of 512x 128 for retina scan with exact scanning speed at 27,000 A-scans per second within a 6mm x 6 mm. Exact Glaucoma Scan pattern of 200 x 200 in a 6 mm x 6 mm cube with exact scanning speed at 27,000 A-scans per second. Scan pattern must be able to capture and provide RNFL, ONH, Neuro Retinal Rim Tissue, and 3-D Cube capabilities all in one scan Have the ability to provide an automated Glaucoma Scan report Motorized Focus Range (Focus Adjustment) must be able to handle patients from minus 20 diopters to plus 20 diopters Capable of scanning speeds at exactly 27,000 A-scans/sec and 68,000 A-scans/sec System must be able to scan and provide a report for Ganglion Cell Analysis that is derived from a scan Must be comprised of a 6 mm x 6 mm cube scan with a minimum of 200 x 200 line scan pattern with no more than 30 microns between each slice Scan not to include Inner Limiting Membrane or the Retinal Nerve Fiber Layer Minimum pupil requirements to be 2.0 mm or less Must utilize a LSO Fundus Camera (Line Scanning Laser Ophthalmoscope) System must automatically track to prior scan Unit must be able to do this without technician needing to align to prior scan Minimal anterior segment scan of 15.5 mm x 5.8 mm in depth Be able to generate a Global Pachymetry report that is comprised of a minimum of 24 radial scans at a minimum of 9 mm in length Must be able to view Cornea Pachymetry map to provide the minimum, average, and maximum value in microns of Cornea thickness in each of the area of central 0-2 mm, 2-5 mm, and 5-7 mm range. Have the ability to provide a 12 radial HD line scan pattern for the Macula/Retina region Magnetic lens attachment for speed and efficiency when changing from posterior to anterior segment scanning. Have the ability to provide an image that is averaged over 100 x through selective profiling Have the ability to produce a GPA (Guided Progression Analysis) Report System Requirements The system must be a 90° configuration, so that the operator must sit 90° of the patient Must be wireless mouse driven, not joystick OCT system must be a self-contained unit Dimensions no larger than 26 L x 18 W x 21 H 2048 Pixel OCT camera Windows 7 OS Live LSO Fundus image Frame rate > 20 Hz Color LCD display Installation & Training: Vendor shall provide all necessary training and installation to bring the equipment to a fully functioning state Fundus Imaging Camera System (Zeiss Product #266002-1160-801-PRO Characteristics and Features: Minimum 24 megapixel sensor Ability to add fluorescein angiography with optional ICGA mode Field angles of at least 45° and 30° Capture modes to include color, red-free, blue, red and fundus auto-fluorescence images, stereo pairs, and images of the anterior segment Optical filters to be included: Filters for green and blue pictures Filters for fundus auto-fluorescence images Filters for UV/IR barrier Ability to compensation for ametropia: continuous from at least +35D to -35D Capture sequence starting at 1.5 seconds Pupil diameter 4.0 mm or 3.3 mm for small pupil mode Working distance of at least 40 mm from patient s eye to front of lens Monitor size preference of minimum 23 TFT with resolution of at least 1920 x 1080 External & internal fixation targets Four sizes of internal fixation targets including a circle for AMD patients Attention mode for internal fixation target Xenon flash lamp with at least 24 flash levels for flash energy (max of 80 W) System Requirements: Basic device dimensions similar to 16 W x 18 D x 28 H inches Rated voltage of 240 V +/- 10% Windows 7 OS Required Hard drive storage of at least 75,000 images Archiving and image analysis system Printer included Installation & Training: Vendor shall provide all necessary training and installation to bring the equipment to a fully functioning state Corneal Topographer (Zeiss Product #266002-1134-240-PRO) Characteristics and Features: Placido disk technology with 22-ring Placido disk 70 mm working distance Digital CMOS Camera with at least 1280 x 1024 resolution Optically magnifies curvature changes Clinical level accuracy in measuring central and peripheral corneal curvatures Cone alignment technology with sub-micron elevation accuracy Reconstructive of corneal surface Corneal Analysis Software Screens for at least 5 different corneal conditions Zernike corneal wavefront analysis Ability to optimize the selection of aspheric IOLs Automatic selection the highest quality image System Requirements: Basic device dimensions similar to 52 L x 37 W x 50 H centimeters Windows 7 OS Required Hard drive storage of at least 35,000 exams Installation & Training: Vendor shall provide all necessary training and installation to bring the equipment to a fully functioning state Requirements also include FORUM Data Management System to include Archive and Viewer Package as well as user licenses with Glaucoma and Retina Workplace Functions, DICOM Interface, Installation, training and service plan. Please e-mail your response advising if the requirements stated above can be met to the following address: contact@example.gov. This Sources Sought Notice is issued solely for informational and planning purposes. No funds are available to fund the information requested. The information in this notice is current as of the publication date but is subject to change and is not binding to the Government. Oral submissions of information are not acceptable. Submit the following information also: - Company Name and Address - Cage Code - DUNs Number - Company business size by NAIC code - Small Business Type (s), if applicable - Point of Contact for questions and/or clarification - Telephone Number, fax number, and email address - Web Page URL - OEM License/Agreement/Manual .

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 236220
New
Federal
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB
Solicitation # 36C25527Q0044
The Department of Veterans Affairs, Network Contracting Office 15, is conducting market research through a Sources Sought Notice to determine the availability of qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms for a construction project at the St. Louis Medical Center Jefferson Barracks. The project involves the replacement of the roof and associated components for Building 51, covering approximately 56,000 square feet. The scope includes installing a 70-mil thermoplastic polyolefin (TPO) roofing system, replacing four skylights, and updating the penthouse roof-access ladder to meet OSHA and VA safety standards. The estimated value of the resulting contract is between 2 million and 5 million dollars, with a required performance period of 222 calendar days from the Notice to Proceed. The project requires the contractor to manage work within an occupied 24/7 facility, necessitating a detailed phasing plan and strict adherence to infection control and HVAC-intake protection. Key technical requirements include providing a 20-year no-dollar-limit warranty, ensuring positive drainage to prevent standing water for more than 48 hours, and submitting as-built record drawings in searchable PDF and editable CAD formats. Interested firms must be registered in SAM.gov under NAICS code 236220 and provide a capability statement by November 9, 2026, including evidence of CVE certification, bonding capability, and a history of comparable work performed within the last five years.
Commercial and Institutional Building Construction

POSTED

about 19 hours ago

DEADLINE

in 10 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS