This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 17, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--36C25523Q0640 - Quantitative Respirator Fit Testers - KC

Closed
36C25523Q0640Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Kansas City VA Medical Center 4801 East Linwood Blvd, Kansas City, KS, 64128, USA

Set-Aside

SBA

Documents

1

36C25523Q0640 - Quantitative Respirator Fit Testers - KC

DOCX, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts
Ashley SchmittContract Specialist

Full Description

Show more
STATEMENT OF WORK (SOW) QUANTITATIVE RESPIRATOR FIT TESTER KIT Name Brand or equal to: Porta count 8048-T A. GENERAL INFORMATION Title of Project: Quantitative Respirator Fit Tester Kit Scope of Work: The Kansas City Veterans Affairs Medical Center (KCVAMC) Occupational Safety & Health Service, located at 4801 Linwood Blvd Kansas City MO 64128, requests 4 quantitative fit test machines. The fit testers should include all associated parts and accessories (including software) necessary for successful stand-alone, out-of-the box fit testing capabilities of both N-95 filtering face-piece respirators and both half and full-face elastomeric respirators. Fit Testing is expected to meet all OSHA requirements for quantitative fit testing as described in the Code of Federal Regulations, 29 CFR 1910.134. Background: A quantitative fit test (QNFT) is one type of respirator fit test used to determine whether a respirator properly fits an individual employee. Respirator fit tests are used with tight fitting respirators to ensure a proper face-to-face-piece seal is achieved. Without a proper fit, ambient air can leak into the respirator and expose the wearer to airborne contaminants. U.S. Occupational Health and Safety (OSHA) regulations require that a respirator fit test be performed when a worker initially selects and is fitted for a tight-fitting respirator. Additional testing must be performed at least annually. Quantitative fit-testing is performed by collecting and analyzing air samples from within the respiratory inlet cover of the respirator while it is worn by the intended user. This collection is accomplished through use of a hose inserted into the face piece of the respirator, which then delivers the air sample to a separate device for analysis. This testing procedure results in a numeric value for the level of contaminants within the respirator by comparing this number to the concentration of the contaminant outside the mask. A fit-factor is calculated that indicates if and at what level any leakage exists when the worker is wearing the selected respirator Note: A quantitative fit test differs from a qualitative fit test because the latter relies on subjective feedback from the wearer to detect potential leaks. Salient Characteristics: The requirements for the fit test machines are listed below: General Characteristics: Fit Tester must be able to perform Fit Testing Procedures as annotated in the OSHA Standard 1910.134, Part A, Fit Testing Procedures-General Requirements, and meet fit testing protocol for: Modified ambient aerosol condensation nuclei counter (CNC) quantitative fit testing protocol for full-facepiece and half-mask elastomeric respirators, Table A-1, and Modified ambient aerosol condensation nuclei counter (CNC) quantitative fit testing protocol for filtering facepiece respirators, Table A-2 Fit Test Machine must contain all accessories for out-of-the box fit testing, peripherals for maintaining operations for up to one year, data storage for both tablet input and software for database management. Compatible tablets should be included with each fit test machine. Contract should provide a minimum of a two-year service agreement for annual cleaning and calibration. Additional Salient characteristics for specific brand or equal to being considered: PortaCount Model 8048-T Porta count 4048-T Salient Characteristics: Compatible with new Modified CNC Protocols OSHA, CSA, HSE and ANSI Compliant for all tight-fitting respirators, including series 95, 99, 100, FFP1, FFP2 and FFP3 filtering facepiece respirators Built-in N95 Companion technology Measures fit factors greater than 10,000 Switch between N95 and N99 mode of operation in seconds Automates fit testing with FitPro+ Fit Test Software Standalone operation - no external computer required Can be used with external computer to generate reports and print fit test cards. Color touchscreen enables operation via touch of a finger, pen or stylus Capable of fit testing in extremely clean environments to include particle generator if required to complete the fit test. Each Fit Tester must include the following: Carry Case AC Adapter with Universal Plug Set 8026 Particle Generator (115 VAC); Alcohol Cartridge Alcohol Fill Capsule; Storage Cap (2) Zero Check Filters; 3/16" and 1/4" Hose Adapters; (2) Spare Alcohol Wicks; (100) Sampling Probes; (100) Lock Washers; Probe Insertion Tool; Neck Strap 8016 Alcohol Supply containing (16) 30mL Bottles of Reagent Grade Isopropyl Alcohol; FitPro Ultra Fit Test Software Data Collector Tablet; USB-A & USB-C Cable; 5-Year Warranty on Repairs Five Annual Factory Clean & Calibration Services w/ Return Shipping included Factory Calibration Certificate Supplemental items for inclusion in this purchase: Fit Test Probe Refill Kit -N-95 (x5) Refill Probe Kit for fit testing disposable filtering-facepiece respirators. 500 Probes, 500 Push Nuts, Instructions. 5. Deliverables: 15 Quantitative Fit Testers ready for operation. 15 Compatible tablets. All accessories including probe devices for penetration 2500 additional probes and nuts for use with disposable filtering facepiece N-95 respirators. 5-year cleaning, maintenance & calibration contract for each fit test machine Software for non-network laptop.

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 238210
New
Federal
657A5-26-111, Triennial Electrical Testing
Solicitation # 36C25526R0186
Solicitation 36C25526R0186 is a negotiated, fixed-price construction contract issued by the Department of Veterans Affairs for triennial electrical testing at the Marion VA Medical Center in Illinois. This project is a total set-aside for Service-Disabled Veteran Owned Small Businesses (SDVOSB) under NAICS code 238210, with an estimated construction magnitude between 500,000 and 1,000,000 dollars. The scope of work involves the maintenance, inspection, adjustment, and testing of the Electrical Power Distribution System, including approximately 325 electrical panels, 135 transformers, 220 switches, 6 generators, and 25 automatic transfer switches. All work must adhere to NETA 2019 specifications, the latest National Electrical Code, VHA Directive 1028, and NFPA 99 and 110 standards. The contract will be awarded based on the Lowest Price Technically Acceptable (LPTA) process, evaluating five key factors: prime contractor past performance, technical construction and electrical testing experience of the prime, technical experience of the electrical subcontractor, qualifications of proposed staffing, and the prime contractor's safety plan. Performance must begin within 10 calendar days of the notice to proceed and be completed within 90 calendar days. Required deliverables include maintenance and testing reports and a schedule of costs submitted within 14 days of award. Proposals must be submitted in three separate volumes covering technical details, pricing via SF 1442, and a bid bond. Additional requirements include compliance with the Davis-Bacon Act, Buy American requirements, and the submission of an electronic security memorandum to maintain the confidentiality of sensitive information.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

about 5 hours ago

DEADLINE

in 10 days
View Details
NAICS: 236220
New
Federal
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB
Solicitation # 36C25527Q0044
The Department of Veterans Affairs, Network Contracting Office 15, is conducting market research through a Sources Sought Notice to determine the availability of qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms for a construction project at the St. Louis Medical Center Jefferson Barracks. The project involves the replacement of the roof and associated components for Building 51, covering approximately 56,000 square feet. The scope includes installing a 70-mil thermoplastic polyolefin (TPO) roofing system, replacing four skylights, and updating the penthouse roof-access ladder to meet OSHA and VA safety standards. The estimated value of the resulting contract is between 2 million and 5 million dollars, with a required performance period of 222 calendar days from the Notice to Proceed. The project requires the contractor to manage work within an occupied 24/7 facility, necessitating a detailed phasing plan and strict adherence to infection control and HVAC-intake protection. Key technical requirements include providing a 20-year no-dollar-limit warranty, ensuring positive drainage to prevent standing water for more than 48 hours, and submitting as-built record drawings in searchable PDF and editable CAD formats. Interested firms must be registered in SAM.gov under NAICS code 236220 and provide a capability statement by November 9, 2026, including evidence of CVE certification, bonding capability, and a history of comparable work performed within the last five years.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 10 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS