Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on December 8, 2020. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--AUDIOSTAR PRO AUDIOMETER

Closed
36C25621Q0232Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources-sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefit from their devices. The requirement includes the provision of equipment with advanced technical specifications, such as dual ear capability, a frequency range of 200 to 16,000 Hz, and a comprehensive test suite including speechmap counseling and pediatric probe tube placement. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

2 days ago

DEADLINE

in 4 days
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

3 days ago

DEADLINE

in 13 days

General Info

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

The Overton Brooks VA Medical Center 510 E. Stoner Ave Shreveport, LA, MS, 71101, USA

Set-Aside

SDVOSBC

Documents

1

36C25621Q0232.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)
Contacts1 person available
OfficeRIDGELAND, MS, 39157, USA
Office AddressRIDGELAND, MS, 39157, USA
Contacts
Ayanna S HamiltonAyanna Hamilton

Full Description

Show more
Department of Veterans Affairs Network Contracting Office 16 - HOUSTON In Support of the Overton Brooks VA Medical Center (OBVAMC) REQUEST FOR INFORMATION 36C25621Q00232 STATEMENT OF WORK Overton Brooks VA Medical Center (OBVAMC) Audiometer Background: The Overton Brooks VA Medical Center (OBVAMC) is requesting an Audiometer to preform hearing exams for the Audiology & Speech Pathology Department. Place of Performance: Overton Brooks VA Medical Center 510 E. Stoner Ave Shreveport, LA 71101 Salient Characteristics for Audiometer: Suggested Manufacturer Brand Name; Audiometer GSI AudioStar Pro or EQUIVALENT as listed below: ITEM SPECIFICATIONS TECHNICAL SPECIFICATIONS DIMENSIONS AND WEIGHT W x D x H (LCD raised): 20.1 in x 14.6 in x 13.2 in (51 cm x 37 cm x 33.5 cm) Height (LCD lowered): 5.5 in (14 cm) Weight: 17 lb (7.7 kg) Shipping Weight: 27 lb (12.25 kg) CHANNELS Two Independent Channels PURE TONE CHANNELS 1 AND 2 FREQUENCY RANGE Air Conduction: 125 Hz - 20,000 Hz* Bone Conduction: 250 Hz - 8,000 Hz Sound Field: 125 Hz - 8,000 Hz Paired Inserts: 125 Hz - 8,000 Hz Frequency Accuracy: ±1% Total Harmonic Distortion: < 2% (earphones and paired insert phones) < 5% (bone vibrator) HEARING LEVEL RANGE Air Conduction: -10 dB HL - 120 dB HL Bone Conduction: Mastoid: -10 dB HL - 90 dB HL Forehead: -10 dB HL - 80 dB HL Sound Field: -10 dB HL - 90 dB HL (basic speakers) -10 dB HL - 96 dB HL (high performance speakers) -10 dB HL - 102 dB HL (high performance speakers and external booster amplifier) Paired Inserts: -10 dB HL - 120 dB HL Masking Intensity Range (Calibrated in effective masking): Narrow Band Noise: Maximum dB HL is 15 dB below tone White Noise: Maximum dB HL is 30 dB below tone SIGNAL FORMAT Steady: Tone continuously present Pulsed: Tone pulsed 200 msec ON, 200 msec OFF FM: Modulation Rate: 5 Hz Modulation Depth: +/- 5% Pulsed/FM: Pulsed and modulated Pediatric Noise Pediatric Noise Pulsed SPEECH CHANNELS 1 AND 2 Microphone: For live voice testing and communications INT/EXT A & INT/EXT B: Can be utilized for internal wave files or recorded speech material from an external digital device INTENSITY RANGE Air Conduction: -10 dB HL - 100 dB HL Bone Conduction: Mastoid: -10 dB HL - 60 dB HL Forehead: -10 dB HL - 50 dB HL Sound Field: -10 dB HL - 90 dB HL Paired Inserts: -10 dB HL - 95 dB HL MASKING INTENSITY RANGE Speech Noise: Air Conduction: -10 dB HL - 95 dB HL Bone Conduction: -10 dB HL - 50 dB HL (mastoid) -10 dB HL - 40 dB HL (forehead) Sound Field: -10 dB HL - 85 dB HL White Noise: Air Conduction: -10 dB HL - 95 dB HL Bone Conduction: -10 dB HL - 60 dB HL (mastoid) -10 dB HL - 50 dB HL (forehead) Sound Field: -10 dB HL - 80 dB HL SPECIAL TESTS ABLB SISI High Frequency Audiometry TEN Test QuickSIN BKB-SIN Tone Decay AMTAS Pro SPECIAL TESTS (USER DEFINED) MLB Lombard test Pure Tone Stenger Speech Stenger SAL Doerfler - Stewart Test PC ENABLED/STAND-ALONE Transfer data to connected PC with an E-Record solution software Print complete report directly to a compatible USB printer COMMUNICATIONS AND MONITORING Talk Forward: Permits the tester to speak through the examiner microphone into the selected transducer Talk Back: Allows the examiner to listen to comments from the patient in the testing booth Monitor: The monitor headset or monitor speaker built into the instrument housing may be used by the examiner to listen to Channel 1, Channel 2, Aux intercom, and/or Talk Back signals Aux Intercom: The built-in Auxiliary Intercom and assistant headset allows the examiner to speak directly to an assistant and allows the assistant to hear what is being presented to the patient On-Board VRA Control: The built-in VRA controls facilitate fast and simple activation of VRA systems STANDARD ACCESSORIES Wireless Keyboard and Mouse Gooseneck Microphone POWER Power Consumption: 90 Watts Voltage & Amperage: 100-240, 1.0 A max Frequency: 50 Hz and 60 Hz ENVIRONMENTAL Temperature: +59° F (15° C) to +104° F (40° C) Storage Temperature: -4° F (-20° C) to +140° F (60° C) Relative Humidity: 5% to 90% (non-condensing) Ambient Pressure Range: 98 kPa to 104 kPa Background Sound Level: < 35 dB(A) Frequency of Use: Once a year to multiple times per day QUALITY SYSTEM Manufactured, designed, developed, and marketed under ISO 13485 certified quality systems COMPLIANCE Designed, tested, and manufactured to meet the following domestic (USA), Canadian, European and International Standards: ANSI S3.6, ANSI S3.43, IEC 60645-1, IEC 60645-2, ISO 389 UL 60601-1 American Standards for Medical Electrical Equipment IEC/EN 60601-1 International Standards for Medical Electrical Equipment CSA C22.2 # 601-1-M90 Medical Device Directive (MDD) Deliverables Schedule: The following parts list includes all items necessary for completion of this project: Item # Description/Part Number/Service* Qty Price Extended Amount - 0001 AUDIOMETER 8518226-GSI AudioStar Pro Version 2 w/ DD45, B81, IP30, and DD450. High Frequency Headphones 1 0002 RAD 8102475 Radioear 90db Wall/Corner mount passive speaker pair W/GSI cable 1 0003 8070 Installation/Training-Advanced 1 0004 Shipping 1 REQUESTED RESPONSES: The intent of this Request for Information is to establish sources to define the procurement strategy (e.g set-aside, sole source, unrestricted) for a solicitation that VA intends to post soon. Interested contractors are requested to respond in accordance with the following: Please respond to this RFI if you can provide the exact brand name products listed in the table in the background section above. In the response please cite your business size status. If you have an existing GSA or VA, Federal Supply Schedule contract, please include the contract details in your response. DISTRIBUTORS: You must provide proof that you are an authorized distributor. VA does not accept grey market items. Please respond to this RFI if you can provide supplies that may be determined EQUIVALENT to the products listed in the table in the background section above. Please provide details on the proposed EQUIVALENT products such as Manufacturer Name, Part Number, and Description. If you have an existing GSA or VA, Federal Supply Schedule contract, please include the contract details in your response. DISTRIBUTORS: You must provide proof that you are an authorized distributor. VA does not accept grey market items. Please note that VA is particularly interested in determining the availability of Small Business Manufacturers. If your company is a small business manufacturer of potentially equivalent items, please respond to this RFI. Vendors are requested to submit estimated market research pricing with their responses. The estimated pricing will be considered when determining the procurement strategy for the future solicitation. (e.g. if CO determines that capable small businesses cannot provide fair and reasonable pricing, then the solicitation will not be set-aside). Please note that if no responses to this notice are received, from either authorized distributors of the cited brand name nor from manufacturers marketing a potentially equivalent brand, then this action will be sole sourced to the manufacturer cited in the Background section above. CONTACT INFORMATION AND RESPONSE DUE DATE: Please email all responses to contact@example.gov. Please respond to this RFI no later than 12/14/2020. DISCLAIMER: This RFI is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this RFI.

More opportunities from Department Of Veterans Affairs → 256-NETWORK Contract Office 16 (36C256)

Same awarding agency

NAICS: 238290
New
Federal
N099--JLM Roll Up Door Replacement
Solicitation # 36C25627Q0092
Solicitation 36C25627Q0092 is a combined synopsis and request for quote issued by the Department of Veterans Affairs for the replacement of a motorized roll-up door at the John L. McClellan Veterans Hospital. This is a 100% set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238290. The project requires the contractor to provide all labor, tools, and equipment, including a scissor lift and forklift, to remove and dispose of the existing door and install one grey 7 by 9 foot motorized rolling steel rapid slat door with insulated slats and an obstruction safety device. The award will be a firm-fixed-price contract with a performance period of 30 days from the Notice to Proceed and includes a one-year warranty. The government will utilize the Lowest Price Technically Acceptable (LPTA) evaluation process, focusing on technical capability, price reasonableness, and the completion of the VA Notice of Limitations on Subcontracting. Interested offerors must submit a three-volume quote package consisting of technical capabilities, a completed price schedule, and the required VAAR certification. Quotes must be emailed to Joseph Warren by 3:00 PM CST on November 18, 2026. A site visit is scheduled for November 6, 2026, at 10:00 AM, and all inquiries must be submitted by November 10, 2026. Performance will take place at the Central Arkansas Veterans Healthcare System in North Little Rock, Arkansas, and contractors must comply with all OSHA, ANSI, CAN, and UL standards.
Other Building Equipment Contractors

POSTED

1 day ago

DEADLINE

in 19 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS