Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 23, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Battery Operated Mobile Lifting Chair w/headrest

Closed
36C26226Q1222Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 339112
New
Federal
SPS Sterilizer
Solicitation # 36C24526Q0758
Solicitation 36C24526Q0758 is a Firm-Fixed Price purchase order for the procurement and installation of five new steam sterilizers and five switch-over control systems for the Sterile Processing Service at the Baltimore VA Medical Center. The project includes the de-installation and disposal of existing equipment, facility work such as plumbing relocation and flooring leveling, and system validation performed by an OEM-trained representative. To ensure continuous operations, installation must be completed in two phases, with the first two units installed followed by the remaining three. While Belimed is the brand name of reference, the government will accept fully equivalent systems that meet specific dimensions and a minimum chamber volume of 275 liters. The award will be granted to the responsible quoter determined to be most advantageous based on technical capability, price, and past performance. Mandatory submission requirements include a detailed line-item worksheet, manufacturer authorization letters for distributors, and specific certifications regarding Service Contract Labor Standards. Delivery must be FOB Destination and completed within 12 months of the award. Contractors are required to maintain general liability insurance of 500,000 dollars per occurrence and comply with strict security prohibitions regarding covered telecommunications equipment. Invoices are to be submitted electronically in arrears upon the receiving and acceptance of goods and services.
245-NETWORK Contract Office 5 (36C245)

POSTED

1 day ago

DEADLINE

in 2 days
NAICS: 339112
New
Federal
Automated Endoscope Reprocessor (BAMC, San Antonio, Texas)
Solicitation # HT940826QE040
Solicitation HT940826QE040 is a combined synopsis and request for quote issued by the Defense Health Agency for the procurement and installation of five automated endoscope reprocessors (AERs) at Brooke Army Medical Center in San Antonio, Texas. The scope of work includes the installation of units across the Gastroenterology, Pulmonary, and Pediatrics departments, as well as the deinstallation and hauling away of twelve existing Olympus OER Pro/Elite systems. The required AERs must be FDA Class II Medical Devices with 510(k) premarket notification, featuring dual-basin designs with cycle times of approximately 22 minutes and compliance with AS/NI/AAMI ST91 and CDC infection prevention guidelines. The contract also requires the provision of compatible hookup blocks, water filtration assemblies, vapor management accessories, a one-year commercial warranty, and comprehensive on-site clinical training for staff. This is a firm-fixed-price acquisition that is not set aside for small business concerns, though it allows for HUBZone price evaluation preferences. Award will be based on the most advantageous offer, considering price, technical literature demonstrating compliance with specifications, and the delivery and installation timeframe. All items must be delivered by November 15, 2026, and must adhere to DoD item unique identification and marking standards per MIL-STD-130 and MIL-STD-129. Quotes must be submitted electronically to the designated points of contact by September 16, 2026. Payment will be processed electronically through the Wide Area WorkFlow (WAWF) system.
Defense Health Agency

POSTED

1 day ago

DEADLINE

in 4 days

AI Contract Overview

Show more

This Request for Information (RFI) is issued by the Department of Veterans Affairs through Network Contracting Office 22 for market research purposes only and does not constitute a solicitation or binding contract. The Government seeks information from potential vendors regarding the supply, installation, configuration, validation, and ongoing technical support and maintenance of a Battery Operated Mobile Lifting Chair with Headrest, specifically for use at the Los Angeles VA Medical Center. The requirement is classified under NAICS code 339112 for Surgical and Medical Instrument Manufacturing, and the equipment must meet detailed technical specifications including a minimum lift capacity of 330 lbs, the ability to perform approximately 80 lifts per charge, a foldable and lightweight design for transport through standard doorways, an adjustable headrest, user-friendly controls, seamless infection control features, long-lasting battery life, automatic safety locks, and compliance with FDA medical device standards. The device must be equivalent to or better than the RAIZER PRO II model and must operate effectively in diverse clinical environments such as emergency departments and rehabilitation areas. Respondents are required to submit comprehensive information via email to Hanan.Mccullick@va.gov by July 30, 2026, including company details, SAM registration number, small business status under the 339112 size standard, whether they are the manufacturer of the product or acting as a distributor, and if the latter, the identity, country of origin, and small business status of the actual manufacturer. Offerors must disclose any existing federal contracts for the same product under GSA FSS, NASA SEWP, or other programs, along with contract numbers and agencies. They must estimate the calendar days required to install and validate the equipment at a facility comparable to the GLA VA Medical Center and provide generalized pricing for market research. Crucially, each respondent must submit detailed capability statements with reference contracts, including the legal name of the client, contract number, specific tasks performed, performance dates, and a verified point of contact for each reference—this includes subcontractors if utilized. Failure to provide all requested information may be interpreted as lack of capability and could negatively impact the Government’s determination to set aside the future procurement for small businesses, including SDVOSBs, VOSBs, 8(a) firms, HUBZone, WOSBs, or SDBs. All respondents must be registered in SAM.gov with current Representations and Certifications, and submissions must be sent via email without use of any other delivery method. No

General Info

VA seeks market info on battery-operated lifting chairs meeting RAIZER PRO II specs for Los Angeles VA Medical Center.

Agency

Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)View Agency

NAICS

339112 - Surgical and Medical Instrument ManufacturingView NAICS

Place of Performance

Department of Veterans Affairs GLA VA HCS, Los Angeles, AZ, 90073

Set-Aside

NONE

Documents

(1)

RFI Sources Sought for Battery Operated Mobile Lifting Chair w/headrest 36C26226Q1222

DOCXsources-sought

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
Contacts1 person available
OfficeGilbert, AZ, 85297, USA
Organization / Agency
Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
View Agency Profile
Office AddressGilbert, AZ, 85297, USA
Contacts
Hanan McCullickContract Specialist

Full Description

Show more
THIS REQUEST FOR INFORMATION (RFI) SOURCES SOUGHT IS ISSUED SOLELY FOR MARKET RESEARCH AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION 1. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research only to make appropriate acquisition decisions and to gain knowledge of Small Businesses, including Service-Disabled Veteran-Owned Small Businesses and Veteran-Owned Small Businesses (SDVOSB/VOSB), who are interested in submitting proposals for this procurement and who are capable of performing the work required for this procurement. 2. The NAICS for this requirement is 339112 Surgical and Medical Instrument Manufacturing 3. The Contractor shall supply, install, configure, and validate a Mobile Lifting Chair w/ headrest product and provide on-going technical support and maintenance services for that installed product for the Los Angeles VA Medical Center located in Los Angeles, California. The required services (installation, configuration, validation, support, and maintenance for Mobile Lifting Chair w/ headrest) shall be provided by the contractor along with all resources necessary to accomplish the deliverables.
4. Interested and capable Contractors are encouraged to respond to this notice not later than Thursday, July 30, 2026 at 03:00 PM PST, by providing the following information via email only to Hanan.Mccullick@va.gov.
(a) Company name (b) Address (c) Point of contact (d) Phone, fax, and email of primary point of contact (e) Contractor s Unique Entity ID (SAM) number (f) Type of small business, if applicable, (e.g. Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), 8(a), HUB-Zone, Woman Owned Small Business, Small Disadvantaged Business, or Small Business). (g) Statement indicating whether your company is considered small under the size standard for the NAICS code identified under this RFI. (h) Statement indicating the product name of the Mobile Lifting Chair w/ headrest product referenced above that you intend to provide for this procurement. (i) Statement indicating whether you are the manufacturer of the Mobile Lifting Chair w/ headrest product that you intend to provide for this procurement. If you intend to provide a Mobile Lifting Chair w/ headrest product manufactured by a company other than your own, state the name of the company whose Mobile Lifting Chair w/ headrest product you intend to provide, the country of origin for the Mobile Lifting Chair w/ headrest product you intend to provide, and whether the company that manufactures that product is a small business under the size standard for the NAICS code identified under this RFI. (j) Statement indicating if you have a current contract to provide the Mobile Lifting Chair w/ headrest that you intend to provide for this procurement, along with the installation, configuration, validation, support, and maintenance services required by this procurement, under either the General Services Administration s Federal Supply Schedule or with NAC, NASA SEWP, or any other federal contract. If yes, provide the contract type and contract number, as well as the identity of the federal agency with whom you hold that contract. (k) Statement indicating how many calendar days you estimate it would take you to install, configure, and validate the Mobile Lifting Chair w/ headrest product that you intend to provide for this procurement in a medical center similar to the GLA VA Medical Center. (l) General pricing for your products/solutions for market research purposes. (m) A capability statement that provides detailed information for one or more reference contracts that demonstrates your experience providing Mobile Lifting Chair w/ headrest that meets the requirements described in the attached DRAFT Statement of Work and demonstrates your experience providing the installation, configuration, validation, support, and maintenance services required by this procurement. GENERAL STATEMENTS OF CAPABILITY ARE NOT ACCEPTABLE. Respondents must provide the following information for each reference contract the respondent identifies as evidence of the respondent s capability to perform the work required by this procurement. Respondents must provide the following information for each reference contract: (1) the legal name of entity with whom the respondent held the contract; (2) the contract number; (3) a description providing details of the specific tasks the respondent performed under that contract; (4) the dates during which the respondent performed the contract; (5) the name, phone number, and email address of a person at the entity with whom the respondent held the contract who can verify the information the respondent provides regarding this reference contract.
If a respondent offers to demonstrate experience through the proposed use of subcontractors, the respondent must identify the legal name of each subcontractor and provide all of the information required above for one or more reference contracts performed by each subcontractor the respondent intends to use.
NOTE: The information requested above is required for the Government to evaluate whether there are sufficient small business concerns of a particular type who are capable of performing the work required by this procurement to determine if this procurement should be set aside for a given type of small business concern. FAILURE TO SUBMIT ALL OF THE INFORMATION REQUESTED ABOVE MAY BE VIEWED BY THE GOVERNMENT AS EVIDENCE THAT THE RESPONDENT LACKS THE ABILITY TO PROVIDE THE MOBILE LIFTING CHAIR W/HEADREST AND SERVICES REQUIRED BY THIS PROCUREMENT. THIS, IN TURN, MAY AFFECT THE GOVERNMENT S DETERMINATION ABOUT WHETHER THE REQUIREMENTS FOR A SET-ASIDE PROCUREMENT HAVE BEEN MET.
5. All Offerors who provide goods or services to the United States Government must be registered in the System for Award Management (SAM) database found at https://www.sam.gov. Registration must include Representations and Certifications. --End of Sources Sought Announcement--
DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
SCHEDULE OF SUPPLIES (BRAND NAME OR EQUAL TO RAIZER PRO II):
SALIENT CHARACTERISTICS: Must have Dimensions (L x W x H): Standing - 655mm x 688mm x 1225mm Lying - 1321mm x 688mm x 277mm Must have a lift weight capacity of 330 lbs. Must have ability to perform approximately 80 lifts per charge, or 40 lifts at maximum load.  Equipped with safety belts and stability features to ensure secure lifting and transfer. Must be capable of lifting individuals of varying weights, accommodating a wide range of users. Built with high-quality materials to withstand regular use in healthcare or home settings. Must have User-Friendly Controls: Intuitive control panel for easy operation, allowing caregivers to lift and lower users smoothly. Must have easy Maintenance: Designed for straightforward cleaning and maintenance, ensuring hygiene and longevity. Must have Adjustable Headrest: Provides additional support and comfort for users during lifting and transferring. Must be Lightweight, compact and foldable, making it easy to transport and store in various environments. Must have a rechargeable battery, allowing for mobility without the need for a power outlet during use. The lift must utilize a rechargeable battery to allow operation throughout patient care areas without requiring connection to an electrical outlet during use. Must Provide additional support and comfort for users during lifting and transferring. Must have Streamlined cleaning processes that facilitate infection control and maintenance. Must have long-lasting battery life that supports extended operational periods without frequent recharging. Must have comprehensive safety features, including automatic locking systems to prevent accidental movement during use. Must have sturdy frame construction designed to withstand regular use in busy clinical environments. Must have intuitive control panel that allows for quick adjustments and operation by staff with minimal training. Must have versatile height adjustment mechanism that accommodates various patient handling scenarios. The equipment must comply with applicable FDA medical device requirements and recognized healthcare safety standards. The lift must include patient head support during lifting and be suitable for use following patient falls. The overall size and weight must permit transport through standard doorways and operation within patient rooms, outpatient clinics, emergency departments, and rehabilitation areas. The equipment must fold or disassemble into transportable components for storage and transport between patient care areas.

More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)

Same awarding agency

NAICS: 621511
New
Federal
Q301--VISN 22 Semen & Vasectomy Test Kits
Solicitation # 36C26226Q1411_1
Solicitation 36C26226Q1411 is a request for a single-award, firm-fixed-price Blanket Purchase Agreement to provide a comprehensive one-stop shop for Semen Analysis and Post Vasectomy Semen Analysis testing for the Department of Veterans Affairs VISN 22 healthcare centers. The contractor is responsible for providing FDA registered prepackaged mail-in kits for home self-collection, managing all logistics, and performing laboratory testing. The requirement includes the provision of all necessary supplies, such as temperature-controlled packaging with seasonal gel packs and non-toxic preservatives, ensuring specimens remain stable for at least 48 hours. The contract structure consists of a base year and four optional years, with annual estimated quantities of 1,104 Full Semen Analysis kits and 636 Post Vasectomy Semen Analysis kits. Notably, the contractor must provide up to two repeat PVSA tests at no additional cost. This procurement is a total small business set-aside under NAICS 62151//621511. The performing laboratory must maintain CLIA certification, although the previous requirement for CAP accreditation has been removed via amendment. Compliance with HIPAA, OSHA bloodborne pathogen standards, and DOT hazardous materials regulations for infectious substances is mandatory. Award will be granted to the responsible offeror who is technically acceptable and provides the lowest price. Following several amendments, the final response deadline for offers is September 18, 2026, at 07:00 Pacific Time.
Medical Laboratories

POSTED

1 day ago

DEADLINE

in 6 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS