This Sources Sought opportunity from Department Of Veterans Affairs was posted on May 12, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
6515--EQUIPMENT - INFUSION DEVICE ANALYZER
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
This Request for Information (RFI) issued by the Department of Veterans Affairs, VISN 02 Network Contracting Office, seeks to identify qualified sources capable of providing an Infusion Device Analyzer that meets detailed technical specifications for use at the VA Hudson Valley Medical Center in Wappingers Falls, New York. The RFI is strictly for market research and planning purposes and does not constitute a solicitation or binding contract; responses will not be evaluated for award, and no future contract will be awarded based on this notice. The desired device must support automated testing via OneQA software, multi-channel testing of up to four infusion pumps simultaneously, and meet precise flow and volume accuracy requirements, including a flow range of 0 to 3000 mL/h with accuracy within ±(1% + 0.005 mL/h) at lower rates and ±2% beyond 500 mL/h. It must perform occlusion testing within a pressure range of -200 to +2600 mmHg with specified accuracy, support bolus and PCA verification, comply with IEC60601-2-24 and IEC61010-1 safety standards, feature a 10-inch touchscreen interface, USB-C and wireless connectivity, store over 10,000 measurements, upload images and instructions, and operate on 19 V DC power. The unit must be compact, weighing approximately 3.8 kg, with specific dimensions. The VA expresses a preference for domestically manufactured products, and respondents must indicate whether their offerings are U.S.-made or foreign-produced. Respondents are required to provide comprehensive information including company details, point of contact, Unique Entity ID from SAM.gov, and business size classification under NAICS 334510, which has a size standard of 1,250 employees. They must disclose their status as a small business, Large Business, or any applicable socioeconomic category such as SDVOSB, VOSB, HUBZone, or WOSB. Manufacturers, distributors, or providers of equivalent solutions must clarify their role and, if a small business reseller, whether they alter, assemble, or modify the device. Large businesses must identify any designated distributors with contact and size information. Respondents must disclose whether they hold any federal contract vehicles like GSA FSS, NAC, or NASA SEWP, and whether the product is available under those contracts. Subcontracting plans require a detailed percentage breakdown of self
General Info
Agency
NAICS
Place of Performance
Hudson Valley VA Medical Center Castle Point Campus., Wappingers Falls, NY, 12590, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 12. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 12, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing (size standard of 1,250 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 02 Network Contracting Office, is seeking sources that can provide Infusion Device Analyzer that at a minimum meet the following salient characteristics for the Hudson Valley Healthcare System: To Be Delivered to: VA Hudson Valley Medical Center Castle Point Campus 41 Castle Point Road Wappingers Falls, NY 12590 The VA has a preference for domestic (manufactured in the United States) content where available. Salient Characteristics: Workflow Automation: Integrated OneQA software for automated testing and documentation. Multi-Channel Testing: Ability to test up to four infusion pumps simultaneously. Accuracy & Resolution: Flow range: 0 3000 mL/h (steady), 0 1500 mL/h (peristaltic). Flow accuracy: ±(1% + 0.005 mL/h) at <500 mL/h; otherwise ±2%. Volume range: 0 100,000 mL; resolution 0.001 mL. Occlusion Testing: Peak pressure range -200 to +2600 mmHg; accuracy ±(1% + 5 mmHg). Bolus & PCA Verification: Supports bolus flow and volume testing. Compliance: Meets IEC60601-2-24 and IEC61010-1 standards. User Interface: Large 10-inch touchscreen with intuitive controls. Connectivity: USB-C for PC communication; wireless capability for field testing. Data Storage: >10,000 measurements; ability to upload pictures and instructions. Dimensions & Weight: Approx. 95 mm × 210 mm × 260 mm; weight ~3.8 kg. Power: 19 V DC, 3 A. The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)? (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? (4) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (6) If you intend to sub contract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to sub contracted work and completion of job. (7) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number. (8) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? (9) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate any type of award. (10) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes? (11) Will the items you will be providing manufactured domestically in the United States or are they foreign manufactured items? (12) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. (13) Please provide your Sam.gov Unique Entity ID number. Responses to this notice shall be submitted via email to Sanchez.Reid@va.gov. Telephone responses shall not be accepted. Responses must be received no later than May 27,2026 at 4:00PM EST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.
More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS
