6515--FY26 Fluent Pro System
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The Department of Veterans Affairs, through its Network Contracting Office 8 based in Tampa, FL, has issued an award notice for the procurement of the FY26 Fluent Pro System under solicitation number 36C24826Q0117. This contract involves the sole-source acquisition of a single Fluent Pro System (part number FLT-200) or an equivalent device intended for use in hysteroscopic procedures at the C.W. Bill Young Veterans Medical Center in Bay Pines, Florida, to replace an existing unit that has reached the end of its service life. The system must meet stringent technical specifications including requirements for system design, pressure and flow monitoring, integration capabilities, safety compliance, physical parameters, and necessary accessories to ensure full operational functionality. The contract is structured as a firm-fixed-price agreement, with a focus on compliance with mandatory performance and safety standards tailored to the delivery and installation of this specialized medical equipment. The Department called for capability statements and verification of authorized servicing capabilities from potential vendors to ensure continued maintenance and operational support post-deployment. The procurement process was scheduled to close its response submissions by November 24, 2025, emphasizing a tight timeline for evaluation and award. Oversight and contract administration will be managed through the designated contracting officer, Michael A. Shook, ensuring clear communication and adherence to the terms established for this critical medical device acquisition.
General Info
Contract Value
$22,500Place of Performance
FL, USASet-Aside
Award Issued Date
Timeline
Organization & Contact Information
Full Description
Equipment Requirement: Minimum Required Features and Specifications System Design and Operation Must be an automated fluid management system with both inflow and outflow (suction) regulation for hysteroscopic procedures. Must use SmartFlo or equivalent adaptive fluid control technology that automatically adjusts flow to maintain target intrauterine pressure. Must include touchscreen interface for real-time visualization of pressure, inflow/outflow volumes, and fluid deficit. Must display real-time deficit values with visual and audible alerts when approaching safety thresholds. Must provide three selectable suction levels (Low, Medium, High) with the capability for rapid suction performance (up to 4× faster than standard Fluent system). Must allow for automatic balancing between inflow and outflow to maintain consistent cavity distention and visualization. Pressure and Flow Monitoring Must measure and display intrauterine pressure in mmHg with accuracy within ±5 mmHg. Must regulate fluid inflow to maintain the surgeon-set pressure throughout resection and evacuation phases. Must allow user-defined safety limits for fluid deficit based on patient condition and procedure type. Integration and Compatibility Must be fully compatible with Hologic MyoSure® tissue-removal devices and accessories currently used at the C.W. Bill Young VAMC. Must support connection to standard wall suction or vacuum source without modification to facility plumbing. Must operate with single-use, disposable tubing sets and FloPak fluid cartridges to ensure sterility and eliminate cross-contamination risk. Must not require custom hardware or external controller interfaces beyond standard operating room power and suction. Safety and Compliance Must provide visual and audible alarms for over-pressure, high deficit, occlusion, and flow interruptions. Must include a built-in safety shut-off to halt inflow if deficit exceeds the pre-set threshold. Must comply with applicable FDA, IEC, and ISO medical electrical equipment standards. Must support use with sterile saline or electrolyte-based distension media. Physical and Utility Requirements Portable tabletop or cart-mounted configuration suitable for OR use. Electrical requirements: standard 120 V AC, 60 Hz hospital outlet. Weight: 40 lb (for easy transport and setup). Must include holder or mount for inflow/outflow fluid bags and waste canister system. Must include integrated display with intuitive user interface for pressure, flow rate, and deficit monitoring. Accessories and Consumables Must include all manufacturer-recommended accessories necessary for installation, calibration, and operation. Must be compatible with existing facility sterilization and waste-handling protocols.
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)
Same awarding agency
Earlier notices in this NAICS code
Posted before this notice, open and closed
Ready to Pursue This Opportunity?
Get AI-powered intelligence on this solicitation and the ones like it
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS
