6515--Phillips Allura Xper FD10 repair St. Louis VAMC

Active
36C25520F0200Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The St. Louis VA Medical Center has issued a contract for emergency repair services on the Philips Allura Xper FD10 X-ray system, which is currently non-operational and requires a tube replacement. The contractor is responsible for providing all labor, travel, materials, tools, supervision, and related incidentals necessary to perform on-site diagnosis and repair in compliance with manufacturer guidelines, Joint Commission standards, and contract specifications. The work will commence immediately upon award and continue until the system is fully functional. All service activities must be thoroughly documented, with reports submitted within seven business days following maintenance or repair, detailing technician arrival and departure times, equipment details, work performed, parts used, and equipment efficiency. Contractor personnel must meet stringent competency requirements, including formal OEM-certified training and at least two years of hands-on experience with the specified equipment. Contractor field service engineers must be qualified and approved by the contracting officer and shall comply with all VA security protocols, including identification, check-in/out procedures, use of personal protective equipment due to potential exposure to infectious materials, and adherence to VA regulations such as parking and weapon prohibitions. Calibration certification for any test equipment used must be traceable to national standards. While IT security accreditation is not required for this contract, strict adherence to facility policies and safety standards is mandated throughout the service period.

General Info

Emergency repair contract for Philips X-ray system tube replacement with certified technicians onsite.

NAICS

334517 - Irradiation Apparatus Manufacturing

Place of Performance

KS

Set-Aside

NONE

Documents

1

Philips Allura Xper FD10 Repair - St. Louis VAMC

DOCX, High priority: read this first5 pages · special-notice
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

Posted

special-notice

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts
Jeanine WallaceContracting Officer

Full Description

Show more
B.3 STATEMENT OF WORK: General Information Service Agreement: The St. Louis VA Medical Center is requesting to establish an emergency service contract for the repair on the Philips Allura Xper FD10. The facility is located at: VA St. Louis Healthcare System John Cochran Division 915 N. Grand Blvd. St. Louis, MO 63106 Scope of Work: The Contractor shall supply all labor, travel, materials, equipment, tools, supervision, and all incidentals required to complete on-site full diagnosis and repair of the equipment identified in Section II, in accordance with Manufacturer s recommendations, Joint Commission standards, design specifications, and the specifications, terms, and conditions of this contract. Performance Period: The Contractor shall begin the work required under this SOW commencing with the effective date of award, unless otherwise directed by the CO, and shall provide continuous service until the X-ray system is fully operational. Equipment to be Serviced Each of the following items is to be serviced in accordance with the specifications, terms and conditions of this contract. Line Item Manufacturer Model EE# Location 1 Philips Allura Xper FD10 142853 B516-01-JC Services to be Provided The Contractor shall supply all labor, travel, materials, equipment, tools, supervision, and all incidentals required to complete on-site full diagnosis and repair. Currently, the X-Ray is down and needs a new tube to be replaced. Documentation/Reports No later than seven (7) business days after the conclusion of any maintenance or repair the Contractor will provide to the COR or Alt COR a signed detailed service/inspection report listing all devices, all repairs for each device, parts used to maintain or repair the devices, and operating efficiency of the devices. The service/inspection report shall contain, at a minimum, the following information: Date and time of the technician s arrival on station. Type, model, and serial number(s) of all equipment on which maintenance was performed. Total time spent performing maintenance (exclusive of any travel time). Detailed narrative description of work performed. Complete list of parts replaced. Comments as to the cause of the malfunction when applicable Date and time the repair/preventive maintenance was completed. Security Requirements Upon arrival at the VA Medical Center, all Contractor personnel shall be required to report to the VA Medical Center Police for a temporary ID and then to the COR for check-in. This check-in process is mandatory. When the service is completed, the personnel shall be required to check out with the COR, Biomedical Engineering Shop Supervisor. The contractor's field service employee shall wear visible identification at all times while on the premises of the VA Medical Center. Competency of Contractor Personnel The Contractor must have an established business, with an office and full time staff. The staff includes a "fully qualified" FSE and a "fully qualified" FSE who will serve as the backup. Fully Qualified" is based upon training and experience in the field. For training, the FSE(s) must have successfully completed a formal OEM Certified (or equivalent) training program for all equipment to be maintained and all equipment to be utilized in the performance of the contract. For field experience, the FSE(s) must have a minimum of two years of experience in the installation, calibration, maintenance and repair of the specific equipment identified in Section II. All work shall be performed by "Fully Qualified" competent FSEs. The Contractor shall provide written assurance of the competency of their personnel and a list of credentials of approved FSEs. The CO may authenticate the training requirements by request training certificates or credentials from the Contractor at any time for any personnel who are providing services. The CO and/or the COR or Alt COR specifically reserve the right to reject any of the Contractor's personnel and refuse them permission to work on equipment. If subcontractor(s) are used, they must meet the same competency standards as Contractor personnel and be preapproved by the CO. The Contractor shall submit any proposed change in subcontractor(s) to the CO for approval or disapproval. Exposure to Blood Borne or Infectious Material There is a potential for exposure to blood borne or other infectious material with equipment throughout the medical centers. All maintenance persons must use the Universal Precautions (i.e. decontamination of medical equipment, wearing protective gloves, aprons, and goggles) during cleaning and maintenance/repair procedures. Test Equipment The Contractor shall provide the COR or Alt COR with a copy of the current calibration certification of all test equipment which is to be used by the Contractor in the performance of this contract. Test equipment calibration shall be traceable to a national standard. Identification, Parking, Smoking, and VA Regulations Contractor s personnel shall wear visible identification at all times while on the premises of the VA. Identification shall include, as a minimum, the employee s name, position, and the contractor s trade name. It is the responsibility of the contractor to park in the appropriate designated parking areas. Information on parking is available from VA Police Service. VA will not invalidate or make reimbursement for parking violations of the contractor under any conditions. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not local district, state, or municipal court. Smoking is prohibited inside all VA buildings. Possession of weapons is prohibited. Enclosed containers, including tool kits, shall be subject to search. Violations of VA regulations may result in citation answerable in the United States (Federal) District Court, not a local district, state or municipal court. IT Security Requirements VA information technology certification and accreditation requirements do not apply to this contract and a security accreditation package is not required.

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 236220
New
Federal
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB
Solicitation # 36C25527Q0044
The Department of Veterans Affairs, Network Contracting Office 15, is conducting market research through a Sources Sought Notice to determine the availability of qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms for a construction project at the St. Louis Medical Center Jefferson Barracks. The project involves the replacement of the roof and associated components for Building 51, covering approximately 56,000 square feet. The scope includes installing a 70-mil thermoplastic polyolefin (TPO) roofing system, replacing four skylights, and updating the penthouse roof-access ladder to meet OSHA and VA safety standards. The estimated value of the resulting contract is between 2 million and 5 million dollars, with a required performance period of 222 calendar days from the Notice to Proceed. The project requires the contractor to manage work within an occupied 24/7 facility, necessitating a detailed phasing plan and strict adherence to infection control and HVAC-intake protection. Key technical requirements include providing a 20-year no-dollar-limit warranty, ensuring positive drainage to prevent standing water for more than 48 hours, and submitting as-built record drawings in searchable PDF and editable CAD formats. Interested firms must be registered in SAM.gov under NAICS code 236220 and provide a capability statement by November 9, 2026, including evidence of CVE certification, bonding capability, and a history of comparable work performed within the last five years.
Commercial and Institutional Building Construction

POSTED

about 11 hours ago

DEADLINE

in 11 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS