Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 2, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Portable Reverse Osmosis Dialysis Machines for the Salt Lake City, VA Medical Center

Closed
36C25926Q0606Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
36C25926Q0858| Sources Sought on Brain Stimulator for Salt Lake City VA Medical Center
Solicitation # 36C25926Q0858
The Department of Veterans Affairs, through Network Contracting Office 19, is conducting a market survey to identify potential sources for a Transcranial Magnetic Stimulation (TMS) machine for the Salt Lake City VA Medical Center. This Sources Sought Notice, under NAICS code 334510, is intended for planning purposes to determine vendor capabilities and socioeconomic size classifications. Interested companies must submit their responses to Lynn Lim by 12:00 pm MT on September 14, 2026, providing company details, entity IDs, delivery timelines, and manufacturer information. The required equipment must be a biphasic waveform stimulator supporting repetitive (rTMS) and Intermittent Theta Burst Stimulation (iTBS) capabilities, featuring air-cooled figure-of-eight coils and a 3D navigation stim guide coil positioning system. The scope of work includes the procurement, delivery, installation, provider training, and ongoing maintenance of the machine at the George E. Whalen VA Medical Center in Salt Lake City, Utah. All equipment must comply with FDA regulations and medical device standards, incorporating safety features such as emergency stop buttons and software safeguards to prevent over-stimulation. Respondents must certify the country of origin for the end products using the Buy American Certificate (FAR 52.225-2) and demonstrate robust quality assurance processes. While the contractor will not have access to sensitive VA information, they are obligated to protect any PHI or PII in accordance with federal guidelines. This notice is for research only and does not constitute a solicitation or a commitment by the government to award a contract.
Network Contract Office 19 (36C259)

POSTED

1 day ago

DEADLINE

in 2 days
NAICS: 334510
New
Federal
Intent to Award Sole/Single Source - USAFSAM/ETB Ultrasound Task Trainer
Solicitation # IASS-AFRL-RMZB-2026-0051
The Air Force Research Laboratory Enterprise Strategies and Initiatives Contracting Division intends to award a sole source, firm fixed-price purchase order to Elevate Healthcare for an ultrasound task trainer to be used at the CSTARS Baltimore Sim Center (ETB) in Baltimore, Maryland. This procurement, identified by solicitation number IASS-AFRL-RMZB-2026-0051 under NAICS code 334510, aims to replace an outdated CPU-style simulator to modernize Point of Care Ultrasound (POCUS) training for Comprehensive Medical Readiness Program rotators, who utilize the facility for approximately 250 hours annually. Elevate Healthcare has been identified as the only vendor capable of providing a system that meets the physical requirements and fully integrates with established POCUS training protocols, ensuring continuity of instruction. The required hardware package must include a manikin, a laptop with installed software, an electromagnetic tracking system, a foot pedal, and necessary peripherals. Additionally, the vendor must provide cardiac and abdominal training packs, as well as curvilinear and TTE ultrasound replacement transducers. The contract requires a minimum one-year warranty and at least one day of virtual training. While the government is proceeding with a single source award under RFO 12.102(a), authorized distributors or responsible sources were given until September 15, 2026, to submit capability statements or exceptions to the sole source intent.
FA2396 USAF Afmc Afrl Pzl Afrl Pzle

POSTED

1 day ago

DEADLINE

in 3 days

AI Contract Overview

Show more

The Department of Veterans Affairs, through Network Contracting Office 19, is seeking market information on portable reverse osmosis dialysis water purification systems for use at the Salt Lake City VA Medical Center. The requirement is for five units that must weigh under 100 pounds, operate effectively across a wide inlet pressure range of 5 to 120 psi, meet AAMI grade water standards, provide up to 0.4 gpm of product water at 77°F with a 50% recovery rate, and be compatible with B. Braun hemodialysis machines in hard water environments. Key features must include endotoxin and bacterial filtration, continuous water condition monitoring, low noise operation, and chemical-free hot water disinfection. The systems must be delivered, installed, and accompanied by operator orientation. This is a sources sought notice, not a solicitation, and no binding obligation or payment will be provided for responses. All submissions must include completed market research data, company information, UEI, business size certifications, FSS/GSA contract details if applicable, and Buy American Act compliance percentages. The NAICS code is 334510 with a small business size standard of 1,250 employees, and responses must be submitted by July 13, 2026, no later than 2:00 PM Eastern Time. Respondents may mark information as proprietary and are limited to eight pages including the cover letter, to be sent via email to the designated contracting officer.

General Info

Five portable reverse osmosis dialysis systems required under 100 lbs, meeting AAMI standards, compatible with B. Braun machines, delivered and installed by July 13, 2026.

Agency

Department Of Veterans Affairs → Network Contract Office 19 (36C259)View Agency

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus ManufacturingView NAICS

Place of Performance

Department of Veterans Affairs George E. Wahlen VA Medical Center, Salt Lake City, UT, 84148-0001, USA

Set-Aside

NONE

Documents

(1)

Sources Sought Notice for Portable Reverse Osmosis Dialysis Machines - Solicitation 36C25926Q0606

DOCXsources-sought

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 19 (36C259)
Contacts1 person available
OfficeGreenwood Village, CO, 80111, USA
Organization / Agency
Department Of Veterans Affairs → Network Contract Office 19 (36C259)
View Agency Profile
Office AddressGreenwood Village, CO, 80111, USA
Contacts
Joseph B. WurmsteinContracting Officer

Full Description

Show more
Sources Sought Notice - Portable Reverse Osmosis Dialysis Machines Disclaimer: This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Information Requested from Industry:
In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List. Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.
Description of Requirement: The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for 5 Portable Reverse Osmosis Dialysis Water Purification Systems to include delivery, set-up, and system orientation for the Salt Lake City VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.
Item No. Item Description 5 Portable Reverse Osmosis Dialysis Machines with delivery, set-up, and system orientation
Required Salient Characteristics:
Weight under 100 lbs Water line filter to protect against endotoxin and ongoing bacterial exposure Must be able to tolerate low and variable inlet water pressures Meets AAMI grade water standards as per ANSI/AAMI 13959 Performance with Low Feed-Water Pressures Continuous Monitoring of Water Conditions Low Noise Operation Chemical-Free Hot Water Disinfection Must be compatible with B. Braun hemodialysis machines and variable water conditions, providing up to 0.4 gpm of product water at 77°F with a 50% nominal recovery rate while operating effectively over a wide inlet pressure range (5 120 psi) and in hard water environments
In response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met: NAICS Code: Company Name: Address: UEI (Unique Entity ID) Number: Contact Name: Phone No.: Email: Business Size Information - Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HUBZone Woman Owned Certified Service-Disabled Veteran Owned Small Veteran Owned Small Business Large Business FSS/GSA Contract Holder: Yes No FSS/GSA Contract Number:
Effective Date/ Expiration Date:
Proposed solution is listed and available on the above FSS/GSA Contract: Yes No Available pricing structure of proposed solution: Pricing Model Please Indicate Availability Below: (Yes / No / NA) All on FSS Open Market only Mix of FSS & Open Market Firm-Fixed Price

Other: (Please explain)

Federal Acquisition Regulation (FAR) Market Rearch Questions: Buy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a: Domestic end product? _____________ (%) Foreign end product? _______________ (%) Country of Origin: Questions for Small Businesses ONLY: Nonmanufacturer Rule (RFO 52.219-33): Does your company manufacturer these proposed items? [  ] yes [  ] no Does your company exceed 500 employees? [  ] yes [  ] no If yes, list # of employees: _________ Does your company primarily engage in the retail or wholesale trade and normally sells the type of item being supplied? [  ] yes [  ] no Does your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [  ] yes [  ] no Does your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [  ] yes [  ] no If yes, what is the manufacturer s name? ________________
Response Instructions: Do not provide more than 8 pages, including cover letter page. Submit your response via email to joseph.wurmstein@va.gov Submit your response NLT 14:00 (Eastern Time) on Monday, July 13, 2026 Mark your response as Proprietary Information if the information is considered business sensitive. VA has identified the appropriate North American Industry Classification System (NAICS) Code as 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing with a Small Business size of 1250 employees. Please identify and explain any NAICS codes your company believes would better represent the predominant work.
(End of Sources Sought)

More opportunities from Department Of Veterans Affairs → Network Contract Office 19 (36C259)

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS