Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Veterans Affairs was posted on June 24, 2020. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Provide and Install Audiology Booth-LAX CBOC (VA-20-00043404)

Closed
36c25220Q0628Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
6515--ForeSite SS Tablet w/Pressure Mapping Sensor System
Solicitation # 36C24827Q0082
The Department of Veterans Affairs, through Network Contracting Office 8, is conducting market research via a Sources Sought Notice to identify authorized sources for the ForeSite SS Tablet Pressure Mapping System manufactured by ForeSite Medical. This effort is for acquisition planning purposes and is not a formal solicitation. The required system is intended for clinical pressure assessment and treatment and must include the tablet platform, pressure-mapping sensors, sensor packs, chargers, software licenses, cables, and all necessary accessories. Key functional requirements include real-time pressure analysis and visualization, patient data storage and reporting, wireless and wired connectivity, and portable battery-powered operation. All equipment must be new and include the manufacturer's standard warranty. Interested vendors must submit electronic responses in PDF or Word format by October 30, 2026. Submissions must include the company name, address, Unique Entity Identifier, point of contact, and business size or socioeconomic status, such as SDVOSB, VOSB, Small Business, or Large Business. Additionally, respondents must provide documentation proving they are authorized to distribute or resell the ForeSite system, an estimated delivery lead time, and confirmation regarding the new condition and warranty of the product. The place of performance is located in Tampa, Florida, under NAICS code 334510.
248-NETWORK Contract Office 8 (36C248)

POSTED

2 days ago

DEADLINE

in about 22 hours
NAICS: 334510
New
Federal
Ocular Scanner
Solicitation # W91CRB-26-AWSP-Scanner-Ultrasonic-Ocular-RPP
The Portfolio Acquisition Executive Maneuver Ground Project Manager Maneuver Medical Systems is soliciting prototype proposals for a Scanner Ultrasonic Ocular device under Other Transaction Authority pursuant to 10 U.S.C. 4022. The objective is to award two prototype agreements for the delivery and demonstration of FDA-approved commercial solutions that provide anatomical visualization and diagnostic imaging of the eye, specifically for the anterior and posterior segments. Awardees are required to deliver four prototype units within 45 to 60 days of award for operational and environmental testing conducted in accordance with MIL-STD-810H. The estimated period of performance is twelve months, with awards expected around the first quarter of fiscal year 2027. The procurement utilizes a comparative best-value methodology, prioritizing technical approach, performance compliance, reliability, schedule realism, and past performance over cost. Key requirements include Trade Agreements Act compliance, MIL-STD-130N marking for hardware, and the provision of ruggedized transport cases. Deliverables encompass the hardware units, comprehensive user and maintenance manuals, cybersecurity documentation, and on-site operator training. Proposals must be submitted as four separate PDF volumes via DoD SAFE or secure email by November 12, 2026. This action is a direct Other Transaction Agreement and is not subject to the Federal Acquisition Regulation or Defense Federal Acquisition Regulation Supplement.
W6QK Acc-Apg

POSTED

2 days ago

DEADLINE

in 14 days

General Info

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

La Crosse, WI, USA

Set-Aside

SBA

Documents

1

S02+-+36C25220Q0628+-Solicitation+%28updated%29.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)
Contacts1 person available
OfficeMILWAUKEE, WI, 53214, USA
Office AddressMILWAUKEE, WI, 53214, USA
Contacts
Christopher RodriguezContract Specialist

Full Description

Show more
Provide, install and certify for ambient noise, one (1) new, modular, single wall, (Type II), audiometric testing room, with a 4" minimum thick, integral sound rated floor system and all required assemblies, that meets all ANSI (American National Standards Institute) S3.1 "Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms" requirements and that meets the following criteria; - Assembled room shall fit in a pre-cast concrete pit, installed by others, with a one-inch space around all vertical room surfaces, that has the following dimensions; 120 5/8" wide by 109 5/8" long with a depth of 7". - Integral floor system shall have RD-3, green, isolators installed on testing room floor assembly to isolate the booth from the floor of the existing concrete pit. - Audiometric testing room shall have one (1) right hand swinging door, with a 42" wide x 73" tall minimum clear opening. Door shall swing outward and shall be located on the right side of the front elevation of the testing booth. Door shall have a deadbolt, keyed lock. - Audiometric testing room integral ceiling panels shall have one (1) 3" diameter, fire sprinkler head access hole installed. Access hole shall be as centrally located within the assembled testing room as possible. Sprinkler head and related piping installed by others. - Audiometric testing room integral ceiling panels shall have two (2) 8" diameter, one (1) each, static intake and exhaust HVAC ceiling silencers with collars. All HVAC connections by others. - Audiometric testing room shall have one (1) 24" wide by 30" tall, 1/4" double glazed, acoustic, one-way glass window installed on the right elevation. - Audiometric testing room shall have one (1) jack panel for clinical audiometric connections. Jack panel shall be located on the left elevation of testing booth and shall have a minimum of twelve (12) 1/4" phone jacks, two (2) USB (Universal Serial Bus) ports and one (1) 1" pass-through port/opening. - Audiometric testing room shall have all LED lighting, interior to the booth with integral light switch located adjacent to the testing booth door. - Interior of the audiometric testing room shall have carpet flooring. - Audiometric testing room shall have five (5) duplex electrical outlets installed. Three (3) duplex outlets on the interior of the booth, spaced evenly and two (2) on the exterior. Exterior electrical outlets shall be installed on the left elevation of the booth and adjacent to the the jack panel. - Audiometric testing room shall have three (3) double-duplex electrical outlets installed. Two (2) double-duplex outlets on the interior of the booth, spaced evenly and one (1) on the exterior. Exterior electrical outlets shall be installed on the left elevation of the booth and adjacent to the jack panel. - Audiometric testing room electrical system and components shall be UL (Underwriters Laboratory) listed and NEC (National Electric Code) compliant and shall be rated for 120v, 20a, 60Hz, and shall be installed per the most current NEC. - Audiometric testing room shall include three (3) empty utility box's, each with pull wire installed. One (1) utility box shall be for a fire alarm strobe, one (1) utility box shall be for a thermostat and one (1) utility box shall be for data connections. Fire alarm strobe and thermostat connections and components shall be VA provided and installed by others. - Provide one (1) each, audiometric testing room Operators manual and Service manual.

More opportunities from Department Of Veterans Affairs → 252-NETWORK Contract Office 12 (36C252)

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS