Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, June 24 at 2:00 PM EDT

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on May 19, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Sources Sought Notice Digital Monitoring System Brand Name or Equal

Closed
36C26326Q0734Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 339112
New
Federal
6515--New Base+4 Hologic Genesis Processors Service Agreement (VA-26-00073009)The Department of Veterans Affairs, through its Network Contracting Office 12 at the Great Lakes Acquisition Center, plans to enter into a single source procurement with Adaptive Technology Resources, Inc. for Custom Bed Controllers. This acquisition is being conducted under FAR 13.106-1(b), which allows for a non-competitive procurement process. Although the government intends to award the contract without competition, other interested entities may express their interest and capabilities by submitting a response by June 22, 2026, at 7:00 a.m. CST. Responses received will be considered to determine whether to proceed with a competitive procurement, but the decision to do so remains at the sole discretion of the government. No solicitation documents are currently available, and the government will not cover any costs incurred during the preparation of responses. This opportunity falls under the North American Industry Classification System code 339112, which pertains to small businesses engaged in Surgical and Medical Instrument Manufacturing. All questions or comments related to this notice should be directed via email to Vernise L. Newton, the contract specialist, by the stated deadline with the subject line referencing the Notice of Intent from SAM.gov. The contract referenced in this notice is titled "6515--New Base+4 Hologic Genesis Processors Service Agreement (VA-26-00073009)" and was posted on June 16, 2026, with responses due by the end of June 22, 2026. The contracting office is located in Milwaukee, Wisconsin.
252-NETWORK Contract Office 12 (36C252)

POSTED

1 day ago

DEADLINE

in 5 days

AI Contract Overview

Show more

The Minneapolis VA Health Care System is conducting a sources sought notice to identify businesses capable of providing Digital Monitoring System supplies, specifically Sentec digital monitoring systems or equivalent devices, for use in their sleep clinic. This notice is for market research purposes only and will not result in a contract award. Vendors interested in participating must submit their organizational information, including unique entity identifiers and proof of capability, by May 29, 2026, via email. Responses should include answers to a series of questions regarding socio-economic status, manufacturer authorization, origin of products, government contract participation, regulatory compliance, subcontracting plans, and delivery estimates. The solicitation addresses criteria such as compliance with certain VA and FAR subcontracting provisions if applicable. The project involves purchasing four Sentec digital monitoring systems designed to continuously measure transcutaneous CO2 and O2 levels non-invasively, aiding in the diagnosis and treatment of respiratory conditions in the VA’s sleep lab. These devices must feature advanced sensor technology, user-friendly interfaces, portability, color touchscreen displays, data trending, integration with electronic health records, configurable alarms, and FDA approval. The procurement includes specific parts like sensors and adapter cables, with a trade-in option for old equipment. Delivery, setup, and training will be coordinated at the Minneapolis VA facility, ensuring readiness for clinical use. This initiative seeks competitive pricing and reliable vendors to support improved patient monitoring and care outcomes.

General Info

Minneapolis VA seeks vendors for four Sentec digital monitors; submit info by May 29, 2026.

Agency

Department Of Veterans Affairs → Network Contract Office 23 (36C263)

NAICS

339112 - Surgical and Medical Instrument Manufacturing View NAICS

Place of Performance

Minneapolis VAMC, Minneapolis, MN, 55417, USA

Set-Aside

NONE

Documents

(1)

Sources Sought Notice 36C26326Q0734 Digital Monitoring System

DOCXsources-sought

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 23 (36C263)
Contacts1 person available
OfficeSaint Paul, MN, 55101, USA
Organization / Agency
Department Of Veterans Affairs → Network Contract Office 23 (36C263)
Office AddressSaint Paul, MN, 55101, USA
Contacts
Joey BloomerContracting Officer

Full Description

Show more
The Minneapolis Medical Center requires Digital Monitoring System Supplies and accessories with the Salient Characteristics listed below. This is a Sources Sought Notice looking for businesses to provide the supplies listed below for market research purposes. No award of a contract will be made from this announcement. If you are a vendor that can provide the requested information above and required supplies described below with competitive pricing, send your information (to include your organization's Unique Entity Identifier number) with a description of proof of capability to: joseph.bloomer@va.gov on or before May 29th, 2026. Only emailed responses will be considered. Additionally, please provide answers as appropriate to the following questions in the table below with your response to this sources sought. Failure to respond to the following questions may affect the acquisition strategy. 1. Identify your organization's socio-economic category.
2. Identify if your organization is the manufacturer of the requested supplies. If you are not the manufacturer, identify the manufacturer of the supplies that you will provide, their socio-economic category and a letter showing that your organization is an authorized distributor for the requested supplies. 
3. Fill out the certificate under FAR Provision 52.225-2(b), identifying the item and its country of origin. ( https://www.acquisition.gov/far/part-52#FAR_52_225_2__d3401e52). If the product is a US domestic end product, write in USA for the item's country of origin.
4. State whether any of the requested supplies may be ordered against a government contract awarded to your organization (e.g Federal Supply Schedule (FSS), General Services Administration (GSA), etc.).
5. Address whether your organization meets the requirements of 13 CFR 121.406 (b)(1)(i), (b)(1)(ii) and (b)(1)(iii) (https://www.ecfr.gov/current/title-13/chapter-I/part-121/subpart-A/subject-group-ECFR0fca5207262de47/section-121.406#p-121.406(b)).
6. State if subcontracting is contemplated for this requirement and what percentage of the requirement will be subcontracted and for what tasks.
7. Provide estimated shipping and delivery information for the requested supplies (e.g. Expected lead time on delivery).
  *If applicable, VAAR 852.219-76 VA Notice of Limitations on Subcontracting Certificate of Compliance for Supplies and Products, will apply to the potential solicitation if set-aside for Veteran Owned Small-Businesses.* *If applicable, VAAR 852.212-71 Gray Market Items, will apply to the potential solicitation.* *If applicable, FAR 52.219-14 Limitations on Subcontracting, will apply to the potential solicitation if set-aside for Small-Businesses. *
STATEMENT OF WORK 1. Project Title Sentec Digital Monitoring System -or- Equivalent for Sleep Clinic FY26 2. Background Currently the Sleep Center uses Radiometer Transcutaneous CO2 Monitors (TCM). Over the last few years there have been consistent problems with our units needing frequent repairs/troubleshooting and displaying erroneous reading resulting in patient care issues with lost data and unavailable equipment. Minneapolis VA has a 4-bed polysomnography lab, each bed has its own TCM. TCM is a vital tool in a sleep lab, it is used when a patient is suspected of having hypoventilation when sleeping. The addition of TCM will help form a clinical diagnosis for Obesity Hypoventilation Syndrome, monitor levels of CO2 built up in the body from supplemental O2 usage, and to show a patients high CO2 level from other comorbidities, such as COPD. TCM s are used during a titration sleep study, as an effective tool, in conjunction with advanced PAP devices, to lower CO2 levels within the body. 3. Scope MVAHCS is seeking a firm fixed price to purchase four new Sentec digital monitoring systems or equivalent. See FAR Clause 52.211-6- Brand Name or Equal (Aug 1999) for additional information. The project includes purchase and delivery.
4. Salient Characteristics The device provides continuous, non-invasive measurement of tcCO2 and tcPO2, allowing for real-time monitoring without the need for frequent blood draws. It uses advanced sensor technology to ensure accurate and reliable readings, which are crucial for patient management, especially in critical care settings. The system is designed with user-friendly interfaces, making it easy for healthcare professionals to operate and interpret the data. Portable making it suitable for use in various hospital locations, including intensive care units, emergency departments, and during patient transport. Color touchscreen that provides clear visualization of monitoring data, trends, and alarms. The device allows for the tracking and trending of patient respiratory parameters over time. It can be integrated with other hospital systems and electronic health records (EHRs), facilitating comprehensive patient monitoring and data management. Configurable alarms and alerts to notify healthcare providers of critical changes in a patient's respiratory status, enabling timely interventions. Device utilizes specialized sensors that are designed to be comfortable for patients and provide high-quality data. FDA Approval Required. 5. Schedule of Items for Salient Characteristics The procurement shall include the following part numbers and descriptions for equivalents: Item # Part Number/Description Qty 1 V-Sign Sensor VS-A/P/N [1/PK] / 101342 4 2 tCOM+ Hospital USA / 104255 4 3 tCOM+ Sensor Adapter Cable Long 103421 [1/PK] / tCOM-AC-L 4 4 tCOM+ PSG Adapter Cable E 103678 [1/PK] / tCOM-PSG-E 4 5 Trade-In Credit: Credit applied to the purchase of a new Sentec Monitor, with the return of hospital-owned competitive CO2 equipment including the sensor to Sentec. / Trade In 4
6. Place of Performance Unless otherwise noted, the contractor shall deliver the items at the facilities of Minneapolis VA Health Care System, One Veterans Drive, Minneapolis, MN 55417, ATTN: Biomed Mike Yakovlev. 7. Delivery/Setup The contractor shall coordinate delivery, setup and training with the on-site Point of Contacts (POCs) listed below: INTENTIONALLY LEFT BLANK