Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 10, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Sternum Saw|540-26-4-248-0041 (VA-26-00080999)

Closed
36C24526Q0659Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
Federal
36C25926Q0858| Sources Sought on Brain Stimulator for Salt Lake City VA Medical Center
Solicitation # 36C25926Q0858
The Department of Veterans Affairs, through Network Contracting Office 19, is conducting a market survey to identify potential sources for a Transcranial Magnetic Stimulation (TMS) machine for the Salt Lake City VA Medical Center. This Sources Sought Notice, under NAICS code 334510, is intended for planning purposes to determine vendor capabilities and socioeconomic size classifications. Interested companies must submit their responses to Lynn Lim by 12:00 pm MT on September 14, 2026, providing company details, entity IDs, delivery timelines, and manufacturer information. The required equipment must be a biphasic waveform stimulator supporting repetitive (rTMS) and Intermittent Theta Burst Stimulation (iTBS) capabilities, featuring air-cooled figure-of-eight coils and a 3D navigation stim guide coil positioning system. The scope of work includes the procurement, delivery, installation, provider training, and ongoing maintenance of the machine at the George E. Whalen VA Medical Center in Salt Lake City, Utah. All equipment must comply with FDA regulations and medical device standards, incorporating safety features such as emergency stop buttons and software safeguards to prevent over-stimulation. Respondents must certify the country of origin for the end products using the Buy American Certificate (FAR 52.225-2) and demonstrate robust quality assurance processes. While the contractor will not have access to sensitive VA information, they are obligated to protect any PHI or PII in accordance with federal guidelines. This notice is for research only and does not constitute a solicitation or a commitment by the government to award a contract.
Network Contract Office 19 (36C259)

POSTED

1 day ago

DEADLINE

in 2 days
NAICS: 334510
New
Federal
Intent to Award Sole/Single Source - USAFSAM/ETB Ultrasound Task Trainer
Solicitation # IASS-AFRL-RMZB-2026-0051
The Air Force Research Laboratory Enterprise Strategies and Initiatives Contracting Division intends to award a sole source, firm fixed-price purchase order to Elevate Healthcare for an ultrasound task trainer to be used at the CSTARS Baltimore Sim Center (ETB) in Baltimore, Maryland. This procurement, identified by solicitation number IASS-AFRL-RMZB-2026-0051 under NAICS code 334510, aims to replace an outdated CPU-style simulator to modernize Point of Care Ultrasound (POCUS) training for Comprehensive Medical Readiness Program rotators, who utilize the facility for approximately 250 hours annually. Elevate Healthcare has been identified as the only vendor capable of providing a system that meets the physical requirements and fully integrates with established POCUS training protocols, ensuring continuity of instruction. The required hardware package must include a manikin, a laptop with installed software, an electromagnetic tracking system, a foot pedal, and necessary peripherals. Additionally, the vendor must provide cardiac and abdominal training packs, as well as curvilinear and TTE ultrasound replacement transducers. The contract requires a minimum one-year warranty and at least one day of virtual training. While the government is proceeding with a single source award under RFO 12.102(a), authorized distributors or responsible sources were given until September 15, 2026, to submit capability statements or exceptions to the sole source intent.
FA2396 USAF Afmc Afrl Pzl Afrl Pzle

POSTED

1 day ago

DEADLINE

in 3 days

AI Contract Overview

Show more

This request for information is directed toward identifying potential suppliers capable of providing a Brand Name Stryker System 9 Sternum Saw along with a compatible battery charging station for use in the Surgical Department at the Louis A. Johnson VA Medical Center in Clarksburg, West Virginia. The device must fully match or exceed the technical specifications of the existing Stryker System 8, including compatibility with interchangeable blades, operating at 14,000 cpm in fast mode and 11,000 cpm in standard mode, with a blade excursion of approximately 0.154 inches, lightweight design not exceeding 2.1 lbs, and full battery operation featuring a wireless charger with foreign object detection. Additional requirements include an IPX9 rating for water resistance, an enhanced anodized coating, high-visibility battery indicators, non-continuous operation mode, ability to verify battery status prior to use, and a minimum one-minute duty cycle. The procurement includes delivery of one sterile battery charger with a NEMA power cord, two copies of operating and service manuals, and training for end-users on device function and operation. The contractor must deliver the equipment within 90 days of contract award and coordinate all deliveries in advance with the Contracting Officer’s Representative. On-site service personnel must comply with VA protocols including signing in and out, submitting to tool bag inspections, adhering to the non-smoking campus policy, and parking in designated areas. Warranty coverage must be one year from full installation, covering all parts, labor, travel, and repair costs, with responses to service requests required within one business day. Service reports including test data, technician names, and dates must be submitted to the COR within five working days of any repair. Responses must include technical literature demonstrating product equivalence, full company details, DUNS/CAGE/SAM UEI, business size, manufacturer or distributor status, country of origin, and an authorized distributor letter certified by the OEM. No binding obligation arises from responses, and any resulting procurement will be announced separately through a formal solicitation.

General Info

Stryker System 9 Sternum Saw with wireless charger, 14,000 cpm, IPX9, 2.1 lbs, one-year warranty, 90-day delivery.

Agency

Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)View Agency

Contract Value

$21,099.36

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus ManufacturingView NAICS

Place of Performance

Department of Veterans Affairs Clarksburg VAMC, Clarksburg, MD, 26301

Set-Aside

NONE

Awardee

STRYKER SALES, LLCView Profile

Award Issued Date

Documents

(1)

RFI 36C24526Q0659 Sternum Saw for VA Medical Center

DOCXrfi

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

1 update
PhaseClosed
Posted

Sources Sought

Amendment 1

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Organization / Agency
Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
View Agency Profile
Office AddressLINTHICUM, MD, 21090, USA
Contacts
Alison KleinContract Officer

Full Description

Show more
This RFI is solely for information and planning purposes and does not constitute a solicitation or obligation on the part of the Government. Per FAR 15.201(e), responses to this notice are not considered offers, shall not be used as a proposal, and cannot be accepted by the Government to form a binding contract. Neither unsolicited proposals nor any other kinds of offers will be considered in response to this notice. No evaluation letters and/or results will be issued to the respondents; however, the Government does reserve the right to contact any respondent and/or respondent reference to obtain additional information. At this time, no solicitation exists; therefore, please do not request a copy of the solicitation. Any resulting procurement action will be the subject of a separate, future announcement. The information is provided for discussion purposes and any potential strategy for this acquisition may change prior to any solicitation release. The acquisition strategy, evaluation methodology, contract type, and any other acquisition decisions are to be determined.
GENERAL: Scope of Services: The purpose of this requirement is to procure a Brand Name Stryker System 9 Sternum Saw, sternum saw and battery charging station for the Surgical Department at the Louis A. Johnson VA Medical Center. The Stryker System 9 Sternum Saw maintains consistency with the facility s existing Stryker System 8 Sternum Saw, ensuring continuity and compatibility with interchangeable components, including disposable blades.
Location: Louis A. Johnson VA Medical Center, 1 Medical Center Drive, Clarksburg, WV 26301
Performance Period: Delivery within 90 days from contract award
WORK HOURS: Hours of Operation: Normal business hours are Monday through Friday, 7:00 a.m. to 4:00 p.m., excluding holidays. Should the Contractor require work afterhours, the Contractor shall arrange in advance with the Contracting Officer s Representative (COR). Delivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 7:00 a.m. to 4:00 p.m., excluding holidays. National Holidays: The holidays observed by the Federal Government are: New Year s Day, Martin Luther King Day, President s Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veteran s Day, Thanksgiving Day, and Christmas Day and any other day specifically declared by the President of the United States to be a national holiday. Contractor may work on holidays with prior communication and coordination.
SPECIFICATIONS: Minimum Technical Requirements: The procurement is for one (1) Sternum Saw and battery charging station for full operational use. The procurement must include the following accessory: One (1) sterile battery charger with a (B) NEMA power cord The device must be fully battery operated The battery charger must be wireless and include foreign object detection technology The device must not exceed dimensions of 6.3 inches (height), 1.6 inches (width), and 7.3 inches (length). The device must operate at 14,000 cpm in fast mode and 11,000 cpm in standard mode. The device must be lightweight for ease of use, with a maximum weight of 2.1lbs The device must operate at 14,000 cpm in fast mode and 11,000 cpm in standard mode The device must provide an excursion (blade movement) of approximately 0.154 inches The device must operate in a non continuous mode The battery system must allow battery status verification prior to use The device must feature high visibility battery indicators designed for improved visibility The device must meet or exceed an IPX9 rating to ensure resistance to high pressure and high temperature water exposure. The device must feature an enhanced anodized coating for greater durability and chemical resistance The device must support a minimum duty cycle of 1 minute of operation Contractor shall provide two copies of the operating and service manuals Delivery Requirements Delivery is required 90 days from award of the contract. Large deliveries are to be coordinated in advance with the COR to ensure necessary planning takes place. Contractor is to provide the COR with shipment tracking information. Training Requirements Contract shall include training for the end-users in the operation of the system. Training shall be on the function and use of the device. Warranty Information The equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment. Warranty support shall include repair of the system Warranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance. Requests for warranty support shall be made to the telephone support number provided by the Contractor. Warranty support requests shall be responded to within 1 day. Contractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services. Service reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer names of the personnel performing work, and the date service was provided. On-Site Procedures Contractor personnel arriving on-site to perform work shall report to the Biomedical Engineering Department. Contractor personnel shall sign in using the department s vendor sign in sheet, filling out all required information. Contractor personnel s tool bags are subject to inspection by the Biomedical Engineering department upon arrival and upon departure. Contractor personnel shall sign out upon completion of visit. Prior to departure, Contractor personnel are required to, at a minimum, verbally report any issues with the equipment to the Biomedical Engineering department, especially noting if the system is still down or not fully repaired. The VA campus is non-smoking. Contractor personnel are required to comply with this policy. Parking. It is the responsibility of the Contractor to park in the appropriate designated parking areas. RESPONSES:  Please include descriptive literature demonstrating the product meets or exceeds the brand name product specified above.  Please provide any product solution or configuration so long as they are equivalent to the brand name product. Responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.  PLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION: Full name and address of company DUNS number/ CAGE Code/ SAM UEI Business Size Manufacturer or Distributor  If distributor, provide full name, business size and address of manufacturer.  Country of Origin designation for all products. Technical Literature that clearly shows product(s) are equivalent. Any additional product solution or configuration that would be beneficial to the functionality of the product line identified.   Authorized Distributor Letter Certified by OEM with a current date.  Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement. 

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 339112
New
Federal
SPS Sterilizer
Solicitation # 36C24526Q0758
Solicitation 36C24526Q0758 is a Firm-Fixed Price purchase order for the procurement and installation of five new steam sterilizers and five switch-over control systems for the Sterile Processing Service at the Baltimore VA Medical Center. The project includes the de-installation and disposal of existing equipment, facility work such as plumbing relocation and flooring leveling, and system validation performed by an OEM-trained representative. To ensure continuous operations, installation must be completed in two phases, with the first two units installed followed by the remaining three. While Belimed is the brand name of reference, the government will accept fully equivalent systems that meet specific dimensions and a minimum chamber volume of 275 liters. The award will be granted to the responsible quoter determined to be most advantageous based on technical capability, price, and past performance. Mandatory submission requirements include a detailed line-item worksheet, manufacturer authorization letters for distributors, and specific certifications regarding Service Contract Labor Standards. Delivery must be FOB Destination and completed within 12 months of the award. Contractors are required to maintain general liability insurance of 500,000 dollars per occurrence and comply with strict security prohibitions regarding covered telecommunications equipment. Invoices are to be submitted electronically in arrears upon the receiving and acceptance of goods and services.
Surgical and Medical Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 2 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS