This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 10, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
6515--Sternum Saw|540-26-4-248-0041 (VA-26-00080999)
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
This request for information is directed toward identifying potential suppliers capable of providing a Brand Name Stryker System 9 Sternum Saw along with a compatible battery charging station for use in the Surgical Department at the Louis A. Johnson VA Medical Center in Clarksburg, West Virginia. The device must fully match or exceed the technical specifications of the existing Stryker System 8, including compatibility with interchangeable blades, operating at 14,000 cpm in fast mode and 11,000 cpm in standard mode, with a blade excursion of approximately 0.154 inches, lightweight design not exceeding 2.1 lbs, and full battery operation featuring a wireless charger with foreign object detection. Additional requirements include an IPX9 rating for water resistance, an enhanced anodized coating, high-visibility battery indicators, non-continuous operation mode, ability to verify battery status prior to use, and a minimum one-minute duty cycle. The procurement includes delivery of one sterile battery charger with a NEMA power cord, two copies of operating and service manuals, and training for end-users on device function and operation. The contractor must deliver the equipment within 90 days of contract award and coordinate all deliveries in advance with the Contracting Officer’s Representative. On-site service personnel must comply with VA protocols including signing in and out, submitting to tool bag inspections, adhering to the non-smoking campus policy, and parking in designated areas. Warranty coverage must be one year from full installation, covering all parts, labor, travel, and repair costs, with responses to service requests required within one business day. Service reports including test data, technician names, and dates must be submitted to the COR within five working days of any repair. Responses must include technical literature demonstrating product equivalence, full company details, DUNS/CAGE/SAM UEI, business size, manufacturer or distributor status, country of origin, and an authorized distributor letter certified by the OEM. No binding obligation arises from responses, and any resulting procurement will be announced separately through a formal solicitation.
General Info
Agency
Contract Value
$21,099.36NAICS
Place of Performance
Department of Veterans Affairs Clarksburg VAMC, Clarksburg, MD, 26301Set-Aside
Awardee
Award Issued Date
Timeline
Submission Closed
Organization & Contact Information
Full Description
GENERAL: Scope of Services: The purpose of this requirement is to procure a Brand Name Stryker System 9 Sternum Saw, sternum saw and battery charging station for the Surgical Department at the Louis A. Johnson VA Medical Center. The Stryker System 9 Sternum Saw maintains consistency with the facility s existing Stryker System 8 Sternum Saw, ensuring continuity and compatibility with interchangeable components, including disposable blades.
Location: Louis A. Johnson VA Medical Center, 1 Medical Center Drive, Clarksburg, WV 26301
Performance Period: Delivery within 90 days from contract award
WORK HOURS: Hours of Operation: Normal business hours are Monday through Friday, 7:00 a.m. to 4:00 p.m., excluding holidays. Should the Contractor require work afterhours, the Contractor shall arrange in advance with the Contracting Officer s Representative (COR). Delivery Hours: The Warehouse is open to receive deliveries Monday through Friday, 7:00 a.m. to 4:00 p.m., excluding holidays. National Holidays: The holidays observed by the Federal Government are: New Year s Day, Martin Luther King Day, President s Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veteran s Day, Thanksgiving Day, and Christmas Day and any other day specifically declared by the President of the United States to be a national holiday. Contractor may work on holidays with prior communication and coordination.
SPECIFICATIONS: Minimum Technical Requirements: The procurement is for one (1) Sternum Saw and battery charging station for full operational use. The procurement must include the following accessory: One (1) sterile battery charger with a (B) NEMA power cord The device must be fully battery operated The battery charger must be wireless and include foreign object detection technology The device must not exceed dimensions of 6.3 inches (height), 1.6 inches (width), and 7.3 inches (length). The device must operate at 14,000 cpm in fast mode and 11,000 cpm in standard mode. The device must be lightweight for ease of use, with a maximum weight of 2.1lbs The device must operate at 14,000 cpm in fast mode and 11,000 cpm in standard mode The device must provide an excursion (blade movement) of approximately 0.154 inches The device must operate in a non continuous mode The battery system must allow battery status verification prior to use The device must feature high visibility battery indicators designed for improved visibility The device must meet or exceed an IPX9 rating to ensure resistance to high pressure and high temperature water exposure. The device must feature an enhanced anodized coating for greater durability and chemical resistance The device must support a minimum duty cycle of 1 minute of operation Contractor shall provide two copies of the operating and service manuals Delivery Requirements Delivery is required 90 days from award of the contract. Large deliveries are to be coordinated in advance with the COR to ensure necessary planning takes place. Contractor is to provide the COR with shipment tracking information. Training Requirements Contract shall include training for the end-users in the operation of the system. Training shall be on the function and use of the device. Warranty Information The equipment shall have a warranty of 1 year from the full installation/acceptance of the equipment. Warranty support shall include repair of the system Warranty support shall include all parts, materials, labor, and travel to complete the repair or maintenance. Requests for warranty support shall be made to the telephone support number provided by the Contractor. Warranty support requests shall be responded to within 1 day. Contractor shall provide a copy of the service report, complete with test data, to the contract COR within five working days after completion of any services. Service reports shall include identifying information about the equipment, all services provided during the service visit, any issues found during the visit, the technician/engineer names of the personnel performing work, and the date service was provided. On-Site Procedures Contractor personnel arriving on-site to perform work shall report to the Biomedical Engineering Department. Contractor personnel shall sign in using the department s vendor sign in sheet, filling out all required information. Contractor personnel s tool bags are subject to inspection by the Biomedical Engineering department upon arrival and upon departure. Contractor personnel shall sign out upon completion of visit. Prior to departure, Contractor personnel are required to, at a minimum, verbally report any issues with the equipment to the Biomedical Engineering department, especially noting if the system is still down or not fully repaired. The VA campus is non-smoking. Contractor personnel are required to comply with this policy. Parking. It is the responsibility of the Contractor to park in the appropriate designated parking areas. RESPONSES: Please include descriptive literature demonstrating the product meets or exceeds the brand name product specified above. Please provide any product solution or configuration so long as they are equivalent to the brand name product. Responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number. PLEASE PROVIDE THE FOLLOWING ADDITIONAL INFORMATION: Full name and address of company DUNS number/ CAGE Code/ SAM UEI Business Size Manufacturer or Distributor If distributor, provide full name, business size and address of manufacturer. Country of Origin designation for all products. Technical Literature that clearly shows product(s) are equivalent. Any additional product solution or configuration that would be beneficial to the functionality of the product line identified.  Authorized Distributor Letter Certified by OEM with a current date. Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.Â
More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS
