Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 24, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--TISSUE ABLATION

Closed
36C26226Q1238Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 339112
New
Federal
SPS Sterilizer
Solicitation # 36C24526Q0758
Solicitation 36C24526Q0758 is a Firm-Fixed Price purchase order for the procurement and installation of five new steam sterilizers and five switch-over control systems for the Sterile Processing Service at the Baltimore VA Medical Center. The project includes the de-installation and disposal of existing equipment, facility work such as plumbing relocation and flooring leveling, and system validation performed by an OEM-trained representative. To ensure continuous operations, installation must be completed in two phases, with the first two units installed followed by the remaining three. While Belimed is the brand name of reference, the government will accept fully equivalent systems that meet specific dimensions and a minimum chamber volume of 275 liters. The award will be granted to the responsible quoter determined to be most advantageous based on technical capability, price, and past performance. Mandatory submission requirements include a detailed line-item worksheet, manufacturer authorization letters for distributors, and specific certifications regarding Service Contract Labor Standards. Delivery must be FOB Destination and completed within 12 months of the award. Contractors are required to maintain general liability insurance of 500,000 dollars per occurrence and comply with strict security prohibitions regarding covered telecommunications equipment. Invoices are to be submitted electronically in arrears upon the receiving and acceptance of goods and services.
245-NETWORK Contract Office 5 (36C245)

POSTED

1 day ago

DEADLINE

in 2 days

AI Contract Overview

Show more

The U.S. Department of Veterans Affairs is conducting market research through a Request for Information to identify capable small businesses, including Service-Disabled Veteran-Owned Small Businesses and Veteran-Owned Small Businesses, that can supply, install, configure, validate, and provide ongoing technical support and maintenance for a Microwave Ablation system at the San Diego VA Medical Center. The requirement is classified under NAICS code 339112 for Surgical and Medical Instrument Manufacturing and specifies a single-antenna microwave ablation system with precise technical parameters including a 150W maximum power output at 2.45GHz, 50-ohm impedance, pulse width modulation, adjustable time settings up to 10 minutes, footswitch control, remote temperature probe with ±1.5°C accuracy, saline cooling, lockout temperature at 80°C, and full compatibility with Emprint ablation catheters. The system must produce consistent ablation margins greater than 5mm and have a footprint no larger than 17 x 19 inches. Interested contractors must respond by July 31, 2026, via email to Hanan.Mccullick@va.gov with comprehensive details including company information, SAM registration number, small business status, the specific product name and manufacturer, whether they are the original equipment manufacturer, existing federal contracts for similar systems, estimated installation timeline, general pricing for market research, and detailed capability statements with verifiable reference contracts demonstrating successful performance of identical or similar installations, configurations, validations, and ongoing maintenance services. Contractors must also disclose if they intend to use subcontractors and provide the same level of detail for each subcontractor’s past performance. All responses are strictly for market research purposes, do not constitute a solicitation, and cannot form a binding contract. Failure to provide all requested information may lead the government to conclude the respondent lacks the capability to perform the required work, potentially impacting decisions on whether to set aside the procurement for small business concerns. Compliance with SAM registration and representations is mandatory for all respondents.

General Info

VA seeks small businesses to supply and support microwave ablation system at San Diego VA by July 31, 2026.

Agency

Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)View Agency

NAICS

339112 - Surgical and Medical Instrument ManufacturingView NAICS

Place of Performance

Department of Veterans Affairs San Diego VA HCS, San Diego, AZ, 92161

Set-Aside

NONE

Documents

(1)

RFI 36C26226Q1238 Tissue Ablation Microwave Ablation System

DOCXsources-sought

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
Contacts1 person available
OfficeGilbert, AZ, 85297, USA
Organization / Agency
Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
View Agency Profile
Office AddressGilbert, AZ, 85297, USA
Contacts
Hanan McCullickContract Specialist

Full Description

Show more
THIS REQUEST FOR INFORMATION (RFI) SOURCES SOUGHT IS ISSUED SOLELY FOR MARKET RESEARCH AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION 1. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research only to make appropriate acquisition decisions and to gain knowledge of Small Businesses, including Service-Disabled Veteran-Owned Small Businesses and Veteran-Owned Small Businesses (SDVOSB/VOSB), who are interested in submitting proposals for this procurement and who are capable of performing the work required for this procurement. 2. The NAICS for this requirement is 339112 Surgical and Medical Instrument Manufacturing 3. The Contractor shall supply, install, configure, and validate a Microwave Ablation product and provide on-going technical support and maintenance services for that installed product for the San Diego VA Medical Center located in San Diego, California. The required services (installation, configuration, validation, support, and maintenance for Microwave Ablation) shall be provided by the contractor along with all resources necessary to accomplish the deliverables.
4. Interested and capable Contractors are encouraged to respond to this notice not later than Friday, July 31, 2026 at 03:00 PM PST, by providing the following information via email only to Hanan.Mccullick@va.gov.
(a) Company name (b) Address (c) Point of contact (d) Phone, fax, and email of primary point of contact (e) Contractor s Unique Entity ID (SAM) number (f) Type of small business, if applicable, (e.g. Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), 8(a), HUB-Zone, Woman Owned Small Business, Small Disadvantaged Business, or Small Business). (g) Statement indicating whether your company is considered small under the size standard for the NAICS code identified under this RFI. (h) Statement indicating the product name of the Microwave Ablation product referenced above that you intend to provide for this procurement. (i) Statement indicating whether you are the manufacturer of the Microwave Ablation product that you intend to provide for this procurement. If you intend to provide a Microwave Ablation product manufactured by a company other than your own, state the name of the company whose Microwave Ablation product you intend to provide, the country of origin for the Microwave Ablation product you intend to provide, and whether the company that manufactures that product is a small business under the size standard for the NAICS code identified under this RFI. (j) Statement indicating if you have a current contract to provide the Microwave Ablation product that you intend to provide for this procurement, along with the installation, configuration, validation, support, and maintenance services required by this procurement, under either the General Services Administration s Federal Supply Schedule or with NAC, NASA SEWP, or any other federal contract. If yes, provide the contract type and contract number, as well as the identity of the federal agency with whom you hold that contract. (k) Statement indicating how many calendar days you estimate it would take you to install, configure, and validate the Microwave Ablation product that you intend to provide for this procurement in a medical center similar to the San Diego VA Medical Center. (l) General pricing for your products/solutions for market research purposes. (m) A capability statement that provides detailed information for one or more reference contracts that demonstrates your experience providing Microwave Ablation that meets the requirements described in the attached DRAFT Statement of Work and demonstrates your experience providing the installation, configuration, validation, support, and maintenance services required by this procurement. GENERAL STATEMENTS OF CAPABILITY ARE NOT ACCEPTABLE. Respondents must provide the following information for each reference contract the respondent identifies as evidence of the respondent s capability to perform the work required by this procurement. Respondents must provide the following information for each reference contract: (1) the legal name of entity with whom the respondent held the contract; (2) the contract number; (3) a description providing details of the specific tasks the respondent performed under that contract; (4) the dates during which the respondent performed the contract; (5) the name, phone number, and email address of a person at the entity with whom the respondent held the contract who can verify the information the respondent provides regarding this reference contract.
If a respondent offers to demonstrate experience through the proposed use of subcontractors, the respondent must identify the legal name of each subcontractor and provide all of the information required above for one or more reference contracts performed by each subcontractor the respondent intends to use.
NOTE: The information requested above is required for the Government to evaluate whether there are sufficient small business concerns of a particular type who are capable of performing the work required by this procurement to determine if this procurement should be set aside for a given type of small business concern. FAILURE TO SUBMIT ALL OF THE INFORMATION REQUESTED ABOVE MAY BE VIEWED BY THE GOVERNMENT AS EVIDENCE THAT THE RESPONDENT LACKS THE ABILITY TO PROVIDE THE MICROWAVE ABLATION AND SERVICES REQUIRED BY THIS PROCUREMENT. THIS, IN TURN, MAY AFFECT THE GOVERNMENT S DETERMINATION ABOUT WHETHER THE REQUIREMENTS FOR A SET-ASIDE PROCUREMENT HAVE BEEN MET.
5. All Offerors who provide goods or services to the United States Government must be registered in the System for Award Management (SAM) database found at https://www.sam.gov. Registration must include Representations and Certifications. --End of Sources Sought Announcement--
DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
SCHEDULE OF SUPPLIES:
SALIENT CHARACTERISTICS: Microwave Ablation system must follow the following specifications and parameters: Single antenna system Footprint no larger than 17 x 19 150W Max power output adjustable in 5W increments Microwave output frequency of 2.45GHz+/- 50MHz Output Impedance 50ohms nominal Pulse width modulated continuous wave Adjustable time settings in 30sec increments with a max time of 10 minutes per activation Footswitch Remote Temperature probe Spherical ablation capabilities Microwave output frequency of 2450 Consistent ablation margins greater that 5mm Saline cooling fluid Remote Temperature probe sensor monitoring tissue temperature at the tip. Probe tip accuracy +/-1.5C Lockout temperature 80 degree Celsius 13G availability Ablation temperature of 17 degree Celsius Fully compatible with eh Emprint ablation catheters

More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS