6515--Transcranial Doppler
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
Solicitation 36C26226Q1357 is a request for quotation from the Department of Veterans Affairs for a Transcranial Doppler system. This is a firm fixed price acquisition set aside for small businesses under NAICS code 339112. The government is seeking a digital, multi-channel system with specific capabilities for micro-emboli detection, spectral and audio recording, and network integration via DICOM and HL7. The requirement is listed as brand name or equal, meaning vendors offering alternative products must provide detailed technical specifications to prove they meet all salient characteristics or be deemed non-responsive. The selected vendor must provide the system on a sturdy trolley with a medical-grade PC, specific probes, and accessories, ensuring delivery to the VA Los Angeles Healthcare System within 90 business days of award. Requirements include an authorized distributor letter, a comprehensive OEM warranty, and 24/7 unlimited telephone support for the life of the system. Quotes must be submitted via email to Hanan McCullick by 3:00 PM PST on August 17, 2026, with all technical inquiries submitted by August 14, 2026.
General Info
Agency
NAICS
Place of Performance
Department of Veterans Affairs GLA VA HCS, Los Angeles, AZ, 90073Set-Aside
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
Vendor Requirements: 1. Vendor shall provide delivery. 2. Vendor shall provide original equipment manufacturer (OEM) comprehensive warranty on the product(s) starting from the first day of delivery. 3. Vendor provides guarantee equipment is free of defects. 4. Authorized distributor letter 5. FOB Destination delivery shall occur within 90 business days after award to the following destination address: Department of Veterans Affairs VA Los Angeles Healthcare System 11301 Wilshire Blvd. Los Angeles CA 90073. (xii) Quotes are to be received no later than 3:00PM PST, August 17, 2026 at email address: Hanan.McCullick@va.gov, subject Quote: # 36C26226Q1357 [VENDOR NAME] late quotes shall not be accepted. Telephone responses shall not be accepted. Any questions regarding this solicitation shall be submitted no later than 10:00 AM PST August 14, 2026.
Schedule of Supplies:
Salient Characteristics Transcranial Doppler Core System Requirements: Digital system with M-Mode display. At least 2 independent channels capable of operating between 1 16/20 MHz. 2 probes that can operate simultaneously. Electronically switchable between pulsed-wave (PW) and continuous-wave (CW) modes for 4 MHz and 8MHz probes. Spectra and audio recording capability. Remote control of all vital functions. User-configurable test protocols for different clinical scenarios. Software Features: 2-channel micro-emboli detection program. Color spectrum M-Mode display. Online display of parameters (depth, mean velocity, SV, PI, RI, power, etc.). Database with data sorting and ability to insert new patient data. Report generation facility. Bi-lateral monitoring software with lightweight headband probe fixation. 4/8-view spectra display during monitoring. Probes and Accessories: 2 MHz TCD probes (2 units). 2 MHz hand-held diagnostic probe (1 unit). Lightweight headband for two probes. Stereo headphones (1 unit). Conductive gel (24 tubes, 200 250 ml each). Installation Considerations: Computer and Connectivity Medical-grade PC with: Pentium IV or higher processor. 512 MB RAM or more. 80 GB or larger HDD. 17 or higher, high-resolution LCD TFT active matrix color display. Windows XP or higher OS. Network compatibility. Network support: DICOM, DICOM Structured Reporting, HL7, GDT, SQL. Unlimited review stations for interpretation and post editing. Power and Portability: Supply on a sturdy trolley. Integrated color laser printer. UPS (uninterruptible power supply). Optional: built-in rechargeable battery for portability. Environmental Operation: Storable in ambient temperature 0-50 degrees Celsius and relative humidity 15-90%. Operable in 20-30 degrees Celsius with humidity <70% Meets IEC-60601-1-2:2001 (or equivalent) safety standards. Summary: A minimum TCD system should be a digital, multi-channel, multi-probe capable unit with robust software for emboli detection, spectral and audio recording, and network integration, supported by a compatible PC, essential probes, accessories, and environmental resilience. These specs ensure the system can be used effectively in neurology, ICU, and neurosurgery settings. Contractor must comply with all VA mandated and local permitted/safety requirements. Contractor will dispose of all boxes, trash and debris resulting from installation IAW hospital policy. Remote Support - The contractor will ensure they understand and implement the IT security requirements for system interconnection documents required per the Memorandum of Understanding or Interconnection Agreement (MOU-ISA). The standard operating procedure (SOP) and a template for a MOU-ISA are located on the Information Protection Risk Management (IPRM) Portal and can be provided to the contractor. The facility will work with the contractor to establish a MOU-ISA for this requirement/equipment. Delivery of equipment will be NLT 120 days ARO. Installation of equipment and/or clinical training will be NLT five months after equipment delivery, if applicable. Support Features: Telephone Support: Must include 24x7x365 Unlimited Telephone Support, 24x7 Go-Live Clinical Support by Telephone per Department, 24x7 Ongoing Clinical Support by Telephone per Department for the life of the system. This support must be at no additional cost to the Government. Facility will sponsor and submit necessary paperwork through appropriate channels in order for equipment contained in this contract to obtain TRM and/or RMF and/or any other necessary cybersecurity approvals. Facility will sponsor and submit necessary paperwork through appropriate channels in order for equipment contained in this contract to obtain AVHE certification/approval. Warranty: Transcranial Doppler System - Two years on system. One year on remote, headset and other accessories. 90 days on probes. Supply items are warranted for 90 days from the date of shipment. The products are warranted to be free from material defects in workmanship or material under normal use and service for the warranty period. Third party items carry OEM warranty.
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)