Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 5 at 2:00 PM EDT

Register Free →

6515--Transcranial Doppler

Active
36C26226Q1217Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)View Agency

NAICS

339112 - Surgical and Medical Instrument ManufacturingView NAICS

Place of Performance

Department of Veterans Affairs GLA VA HCS, Los Angeles, AZ, 90073

Set-Aside

NONE

Documents

(1)

36C26226Q1217.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseSources Sought
Posted

Sources Sought

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
Contacts1 person available
OfficeGilbert, AZ, 85297, USA
Organization / Agency
Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
View Agency Profile
Office AddressGilbert, AZ, 85297, USA
Contacts
Hanan McCullickContract Specialist

Full Description

Show more
THIS REQUEST FOR INFORMATION (RFI) SOURCES SOUGHT IS ISSUED SOLELY FOR MARKET RESEARCH AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION 1. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research only to make appropriate acquisition decisions and to gain knowledge of Small Businesses, including Service-Disabled Veteran-Owned Small Businesses and Veteran-Owned Small Businesses (SDVOSB/VOSB), who are interested in submitting proposals for this procurement and who are capable of performing the work required for this procurement. 2. The NAICS for this requirement is 339112 Surgical and Medical Instrument Manufacturing 3. The Contractor shall supply, install, configure, and validate a Transcranial Doppler product and provide on-going technical support and maintenance services for that installed product for the Los Angeles VA Medical Center located in Los Angeles, California. The required services (installation, configuration, validation, support, and maintenance for Transcranial Doppler) shall be provided by the contractor along with all resources necessary to accomplish the deliverables.
4. Interested and capable Contractors are encouraged to respond to this notice not later than Wednesday, July 29, 2026 at 03:00 PM PST, by providing the following information via email only to Hanan.Mccullick@va.gov.
(a) Company name (b) Address (c) Point of contact (d) Phone, fax, and email of primary point of contact (e) Contractor s Unique Entity ID (SAM) number (f) Type of small business, if applicable, (e.g. Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), 8(a), HUB-Zone, Woman Owned Small Business, Small Disadvantaged Business, or Small Business). (g) Statement indicating whether your company is considered small under the size standard for the NAICS code identified under this RFI. (h) Statement indicating the product name of the Transcranial Doppler product referenced above that you intend to provide for this procurement. (i) Statement indicating whether you are the manufacturer of the Transcranial Doppler product that you intend to provide for this procurement. If you intend to provide a Transcranial Doppler product manufactured by a company other than your own, state the name of the company whose Transcranial Doppler product you intend to provide, the country of origin for Transcranial Doppler product you intend to provide, and whether the company that manufactures that product is a small business under the size standard for the NAICS code identified under this RFI. (j) Statement indicating if you have a current contract to provide Transcranial Doppler product that you intend to provide for this procurement, along with the installation, configuration, validation, support, and maintenance services required by this procurement, under either the General Services Administration s Federal Supply Schedule or with NAC, NASA SEWP, or any other federal contract. If yes, provide the contract type and contract number, as well as the identity of the federal agency with whom you hold that contract. (k) Statement indicating how many calendar days you estimate it would take you to install, configure, and validate the Transcranial Doppler product that you intend to provide for this procurement in a medical center similar to the Los Angeles VA Medical Center. (l) General pricing for your products/solutions for market research purposes. (m) A capability statement that provides detailed information for one or more reference contracts that demonstrates your experience providing Transcranial Doppler that meets the requirements described in the attached DRAFT Statement of Work and demonstrates your experience providing the installation, configuration, validation, support, and maintenance services required by this procurement. GENERAL STATEMENTS OF CAPABILITY ARE NOT ACCEPTABLE. Respondents must provide the following information for each reference contract the respondent identifies as evidence of the respondent s capability to perform the work required by this procurement. Respondents must provide the following information for each reference contract: (1) the legal name of entity with whom the respondent held the contract; (2) the contract number; (3) a description providing details of the specific tasks the respondent performed under that contract; (4) the dates during which the respondent performed the contract; (5) the name, phone number, and email address of a person at the entity with whom the respondent held the contract who can verify the information the respondent provides regarding this reference contract.
If a respondent offers to demonstrate experience through the proposed use of subcontractors, the respondent must identify the legal name of each subcontractor and provide all of the information required above for one or more reference contracts performed by each subcontractor the respondent intends to use.
NOTE: The information requested above is required for the Government to evaluate whether there are sufficient small business concerns of a particular type who are capable of performing the work required by this procurement to determine if this procurement should be set aside for a given type of small business concern. FAILURE TO SUBMIT ALL OF THE INFORMATION REQUESTED ABOVE MAY BE VIEWED BY THE GOVERNMENT AS EVIDENCE THAT THE RESPONDENT LACKS THE ABILITY TO PROVIDE THE TRANSCRANIAL DOPPLER AND SERVICES REQUIRED BY THIS PROCUREMENT. THIS, IN TURN, MAY AFFECT THE GOVERNMENT S DETERMINATION ABOUT WHETHER THE REQUIREMENTS FOR A SET-ASIDE PROCUREMENT HAVE BEEN MET.
5. All Offerors who provide goods or services to the United States Government must be registered in the System for Award Management (SAM) database found at https://www.sam.gov. Registration must include Representations and Certifications. --End of Sources Sought Announcement--
DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
SCHEDULE OF SUPPLIES:
SALIENT CHARACTERISTICS: Transcranial Doppler Core System Requirements: Digital system with M-Mode display. At least 2 independent channels capable of operating between 1 16/20 MHz. 2 probes that can operate simultaneously. Electronically switchable between pulsed-wave (PW) and continuous-wave (CW) modes for 4 MHz and 8MHz probes. Spectra and audio recording capability. Remote control of all vital functions. User-configurable test protocols for different clinical scenarios. Software Features: 2-channel micro-emboli detection program. Color spectrum M-Mode display. Online display of parameters (depth, mean velocity, SV, PI, RI, power, etc.). Database with data sorting and ability to insert new patient data. Report generation facility. Bi-lateral monitoring software with lightweight headband probe fixation. 4/8-view spectra display during monitoring. Probes and Accessories: 2 MHz TCD probes (2 units). 2 MHz hand-held diagnostic probe (1 unit). Lightweight headband for two probes. Stereo headphones (1 unit). Conductive gel (24 tubes, 200 250 ml each). Installation Considerations: Computer and Connectivity Medical-grade PC with: Pentium IV or higher processor. 512 MB RAM or more. 80 GB or larger HDD. 17 or higher, high-resolution LCD TFT active matrix color display. Windows XP or higher OS. Network compatibility. Network support: DICOM, DICOM Structured Reporting, HL7, GDT, SQL. Unlimited review stations for interpretation and post editing. Power and Portability: Supply on a sturdy trolley. Integrated color laser printer. UPS (uninterruptible power supply). Optional: built-in rechargeable battery for portability. Environmental Operation: Storable in ambient temperature 0-50 degrees Celsius and relative humidity 15-90%. Operable in 20-30 degrees Celsius with humidity <70% Meets IEC-60601-1-2:2001 (or equivalent) safety standards. Summary: A minimum TCD system should be a digital, multi-channel, multi-probe capable unit with robust software for emboli detection, spectral and audio recording, and network integration, supported by a compatible PC, essential probes, accessories, and environmental resilience. These specs ensure the system can be used effectively in neurology, ICU, and neurosurgery settings. Contractor must comply with all VA mandated and local permitted/safety requirements. Contractor will dispose of all boxes, trash and debris resulting from installation IAW hospital policy. Remote Support - The contractor will ensure they understand and implement the IT security requirements for system interconnection documents required per the Memorandum of Understanding or Interconnection Agreement (MOU-ISA). The standard operating procedure (SOP) and a template for a MOU-ISA are located on the Information Protection Risk Management (IPRM) Portal and can be provided to the contractor. The facility will work with the contractor to establish a MOU-ISA for this requirement/equipment. Delivery of equipment will be NLT 120 days ARO. Installation of equipment and/or clinical training will be NLT five months after equipment delivery, if applicable. Support Features: Telephone Support: Must include 24x7x365 Unlimited Telephone Support, 24x7 Go-Live Clinical Support by Telephone per Department, 24x7 Ongoing Clinical Support by Telephone per Department for the life of the system. This support must be at no additional cost to the Government. Facility will sponsor and submit necessary paperwork through appropriate channels in order for equipment contained in this contract to obtain TRM and/or RMF and/or any other necessary cybersecurity approvals. Facility will sponsor and submit necessary paperwork through appropriate channels in order for equipment contained in this contract to obtain AVHE certification/approval. Warranty: Transcranial Doppler System - Two years on system. One year on remote, headset and other accessories. 90 days on probes. Supply items are warranted for 90 days from the date of shipment. The products are warranted to be free from material defects in workmanship or material under normal use and service for the warranty period. Third party items carry OEM warranty.

Similar Contracts

Same NAICS industry code

NAICS: 339112
New
DIBBS
MANIFOLD ASSEMBLY, OXYGThe manifold assembly is an oxygen delivery system certified to distribute therapeutic oxygen to up to five patients from a single inlet, featuring one DISS male inlet, five DISS male outlets, five check valves, and five dust covers, all housed in a nylon carrying case. It includes a DISS female-to-female oxygen coupler for secure and reliable connections. The unit must comply with Medical Marking Standard No. 1 for identification and labeling, replacing any prior reference to MIL-STD-129, and packaging must meet commercial standards specified in the procurement document, ensuring each unit is sealed in a container that protects against damage and breakage. Exterior shipping containers must be suitable for commercial carriers, optimized for the lowest cost, and capable of safe delivery to the designated point of delivery, particularly when exporting. All technical and quality requirements are governed by the DLA Master List of Technical and Quality Requirements, with applicable revisions controlled by the solicitation or award date depending on acquisition scale. The item is identified by NSN 6515-01-342-9182, with a quantity of three units required, a delivery deadline of five days after order, and is subject to federal procurement under contract SPE2DS-26-T-261E, administered by the Department of Defense through the Medical Supply Chain MD Surg FSF office in San Antonio, Texas.
MEDICAL SUPPLY CHAIN MD SURG FSF

POSTED

about 20 hours ago

DEADLINE

in 5 days
View Details

More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)

Same awarding agency

NAICS: 485991
New
Federal
Non-Emergent Medical Transportation Services - Phoenix VA Healthcare SystemThis solicitation seeks a Fixed-Price Indefinite Quantity contract for Non-Emergent Medical Transportation (NEMT) services for the Phoenix VA Healthcare System, structured as a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside under NAICS code 485991, with a base year and four option years running through December 31, 2030. The contract requires 24/7 transportation services including wheelchair, stretcher, and ambulatory transports for Veterans traveling to and from VA facilities, contracted nursing homes, and the Emergency Department, with the majority of trips occurring Monday through Friday between 6:00 a.m. and 8:00 p.m., excluding Federal holidays. Pricing is structured with fixed unit rates for base services such as single-person ambulatory trips, rideshare additions, long-distance mileage beyond 27 miles, and on-vehicle oxygen delivery, with a zero-dollar line item for emergency repairs requiring prior approval. The government specifies a detailed Performance Work Statement requiring compliance with all operational standards, including mandatory training in the VA VetRide system, implementation of a Quality Control Plan with no page limit, adherence to clinical policies such as TB and COVID-19 protocols, and a contingency plan for VetRide system outages. All personnel, vehicles, and certifications must be fully prepared prior to contract start. Proposals must be submitted via email only no later than 10:00 a.m. Mountain Time on August 5, 2026, to Katharine Robert at katharine.robert@va.gov, formatted in two volumes—one containing technical submittals including the Management Plan capped at ten pages and QCP, and the other containing the executed price schedule and signed attachments. Offerors must be certified SDVOSBs with a current Unique Entity Identifier and CAGE code, and must have updated all SAM representations and certifications within the past 12 months. The contract integrates numerous Federal Acquisition Regulation clauses including Service Contract Labor Standards, Contractor Code of Business Ethics, Whistleblower Rights, and prohibitions on unmanned aircraft systems from foreign entities. Invoicing must be submitted electronically through VA’s Electronic Invoice Presentment and Payment System or compliant X12 EDI formats, and must contain specific details including TIN, shipment data, and payment terms. Evaluation will be based on Technical Capability, Past Performance, and Price using a trade-off process, allowing award to the most advantageous propos
Special Needs Transportation

POSTED

1 day ago

DEADLINE

in 20 days
View Details
NAICS: 339112
New
Federal
6515--CEREC PRIMEMILL UNITThe U.S. Department of Veterans Affairs through the 262-NETWORK Contract Office 22 is seeking information on potential sources for the CEREC PRIMEMILL UNIT, identified by solicitation number 36C26226Q1199 and classified under NAICS code 339112 for dental equipment and supplies. The opportunity is posted as a sources-sought notice with no set-aside designation, meaning it is open to all eligible vendors regardless of business size or status. Interested parties are required to submit responses by the deadline of July 27, 2026, at 3:00 PM Eastern Time, and all submissions must address the technical and commercial capabilities necessary to provide the specified unit. The contract will be managed from the agency's office located in Gilbert, Arizona, with performance expected in Los Angeles, California, specifically at the 90073 ZIP code area. The point of contact for this solicitation is Contract Specialist Ervin Hawkins, reachable via email at ervin.hawkins@va.gov, who can be consulted for inquiries regarding submission requirements or procedural details. This notice is part of the federal procurement process to gather market research and identify qualified suppliers capable of delivering the CEREC PRIMEMILL UNIT, which is a digital dental milling device used for creating restorations such as crowns and inlays. While no specific delivery schedule or quantity is stated in the notice, responders are expected to provide comprehensive information about their product offerings, pricing, warranty, support, and compliance with federal acquisition standards. The full solicitation details, including any submission templates or evaluation criteria, are available through the official SAM.gov link provided.
Surgical and Medical Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 4 days
View Details
NAICS: 238210
New
Federal
N040--NVR REDUNDANCY INSTALLATIN FOR CCTV SYSTEMThe Department of Veterans Affairs is conducting a sources sought announcement to identify qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HUBZone, and other small businesses capable of providing and installing network expansion components for the San Diego VA Health Care System’s CCTV infrastructure. The required deliverables include six 10GB fiber expansion card modules, eleven 10 GB optical SFPs compatible with Avigilon NVR4s, and twenty-two 15ft optical patch cables, with full installation, configuration, programming, testing, and validation of the modules and SFPs across thirteen NVRs to ensure redundancy. Eleven of the twenty-two SFPs will be provided by the VA facility, and all work must be scheduled and confirmed with the Contracting Officer Representative. Responses must include complete company information, small business certification type, and a detailed capability statement demonstrating technical expertise, and must be submitted via email to Felicia Simpson by 10:00 am MST on July 21, 2026. This announcement is strictly for market research and does not obligate the government to award a contract or reimburse any costs incurred in responding. The acquisition is classified under NAICS code 238210 with a potential value of $19 million and is initially targeted for a Service-Disabled Veteran Owned Small Business set-aside as mandated by Public Law 109-461, though the government reserves the right to pursue alternate set-asides or full and open competition if qualified responses are insufficient. All responders must be registered in the System for Award Management and, if applicable, in the SBA’s Dynamic Small Business Search Registry. Contractors must submit an electronic installation and service report within seven calendar days of completion, detailing all equipment installed, services rendered, and any maintenance recommendations, as well as report any unsafe conditions or misuse of equipment. No subcontracting opportunities are anticipated, and submissions must clearly indicate the company’s ability to perform the specific scope of work described.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

1 day ago

DEADLINE

in 1 day
View Details