Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on June 14, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Ventilator Non-invasive and Invasive

Awarded
36C25523Q0541Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Contract Value

$259,113.6

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Harry S. Truman Memorial Veterans' Hospital 800 Hospital Drive, Columbia, KS, 65201-5275

Set-Aside

NONE

Award Issued Date

Documents

1

Sources Sought: Ventilator Non-invasive and Invasive (36C25523Q0541)

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts
Michael P. MurphyContract Specialist

Full Description

Show more
This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) UIE number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below. Work to be performed: HARRY S TRUMAN MEMORIAL VETERANS HOSPITAL 800 Hospital Drive Columbia, Mo 65201 Ventilator Non-Invasive and Invasive Statement of Work Harry S. Truman Memorial Veterans Hospital requires the purchase of Sixteen (16) ventilators with the capacity to deliver non-invasive and invasive ventilation to patients with Hypercapnia, Hypoxemia, Critical Respiratory Failure and Chronic Obstructive Sleep Apnea via mask, ETT or trach. The device should also have the capability to deliver High Flow Oxygen (HFO) via nasal cannula interface. The Noninvasive/Invasive Ventilator must be a microprocessor-controlled, ventilatory assist system that will provide continuous or intermittent positive pressure ventilatory support, either noninvasively or invasively, for Spontaneous breathing patients > 12.5kg with a tidal volume of 100ml or greater but need mechanical ventilation. The system must be capable of operating with single-limb passive BiPAP circuits, exhalation valve active circuits, and be capable of operating with or without a proximal flow sensor. The Noninvasive/Invasive Ventilator system must be cleared by the FDA to operate with noninvasive masks, endotracheal tubes and tracheostomy tubes. MUST MEET OR EXCEED SALIENT CHARACTERISTICS BELOW: The Noninvasive/Invasive ventilator must have a touch screen, color display to allow the user to easily access ventilator settings and monitored parameters. The Noninvasive/Invasive ventilator must have operator-adjustable and non-adjustable alarms help ensure the patient s safety. The Noninvasive/Invasive ventilator must have visible and audible alerts to provide notification of ventilator alerts/alarms. The Noninvasive/Invasive ventilator must incorporate a dual HEPA filtration system. All entrained air will pass through two HEPA filters prior to reaching the patient. The Noninvasive/Invasive ventilator must utilize high-pressure oxygen, but must have an integrated Turbine to provide pressurized gas for delivery to the patient, no high pressure air connection required. The Noninvasive/Invasive ventilator must also have the ability to utilize Low Pressure Oxygen < 12 psi (flows 1-12 l/min) in the absence of high-pressure oxygen. The Noninvasive/Invasive ventilator must use as its primary power source AC mains, but there must be an internal backup battery. The Noninvasive/Invasive ventilator must be able to be mounted to a roll stand. There must be cylinder holders on the stand to accommodate two E-size oxygen cylinders. The Noninvasive/Invasive ventilator must have the ability to measure, display and alarm low/high oxygen saturation (SpO2) and Exhaled carbon dioxide (ETCO2) The noninvasive/Invasive ventilator must be able to store up to 72 hours of operational logs, alarms, waveforms and measured parameters for review of clinical data. Modes of Ventilation: (most abbreviations are industry standard) Spont-PS Continuous positive airway pressure (Cpap) with pressure support S/T Spontaneous with timed backup respiratory rate PCV Pressure control ventilation PRVC Pressure regulated volume control PPV Proportional pressure support ventilation O2 Therapy High flow oxygen therapy Monitoring Waveform Data: (most abbreviations are industry standard) Peak airway pressure Flow Volume SpO2 Plethysmogram EtCO2 Measured/Monitored/Displayed Data: (most abbreviations are industry standard) PIP I:E Ratio PEEP TI/TTOT Insp Flow Insp Time Exp Flow Exp Time Spont Insp Minute Volume Patient Leak Spont Exp Minute Volume Total Leak Insp Tidal Volume Leak % Exp Tidal Volume Patient Trigger Exp Tidal Volume per kg body weight FiO2 Total Resp Rate SpO2 Spont Resp Rate Alarm Settings: (most abbreviations are industry standard) High PIP Apnea Low PIP High FiO2 High PEEP Low FiO2 Low PEEP High SpO2 High MV Low SpO2 Low MV High HR High VT Low HR Low VT High EtCO2 High RR Low RR Important information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service-Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open. Any response to this source selection from Interested parties must be received NLT 06/21/2023, 1200 PM CST. Attention: Michael Murphy, Contracting Specialist. Email: contact@example.gov Please put 36C25523Q0541 Ventilators in the subject line of all emails. Please provide your Unique Entity ID so that your organization can be identified in SAM.GOV and VetBiz if organization is claiming SDVOSB preference. Only organizations with an active SAM.GOV account can be considered. Utilize this link to either start a new registration or to renew the organization s registration. https://sam.gov/content/home

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 236220
New
Federal
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB
Solicitation # 36C25527Q0044
The Department of Veterans Affairs, Network Contracting Office 15, is conducting market research through a Sources Sought Notice to determine the availability of qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms for a construction project at the St. Louis Medical Center Jefferson Barracks. The project involves the replacement of the roof and associated components for Building 51, covering approximately 56,000 square feet. The scope includes installing a 70-mil thermoplastic polyolefin (TPO) roofing system, replacing four skylights, and updating the penthouse roof-access ladder to meet OSHA and VA safety standards. The estimated value of the resulting contract is between 2 million and 5 million dollars, with a required performance period of 222 calendar days from the Notice to Proceed. The project requires the contractor to manage work within an occupied 24/7 facility, necessitating a detailed phasing plan and strict adherence to infection control and HVAC-intake protection. Key technical requirements include providing a 20-year no-dollar-limit warranty, ensuring positive drainage to prevent standing water for more than 48 hours, and submitting as-built record drawings in searchable PDF and editable CAD formats. Interested firms must be registered in SAM.gov under NAICS code 236220 and provide a capability statement by November 9, 2026, including evidence of CVE certification, bonding capability, and a history of comparable work performed within the last five years.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 10 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS