This Sources Sought opportunity from Department Of Veterans Affairs was posted on August 27, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6540-- 541-26-3-2611-0455 - PowerRef 3 System Hardware/Software

Closed
36C25026Q0950Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Department of Veterans Affairs, Network Contracting Office 10, is issuing this Request for Information to identify qualified sources capable of providing the PlusOptix PowerRef 3 Accommodation Meter and associated accessories for the Louis Stokes Cleveland VA Medical Center. This equipment is required for a VA-ORD-funded study on binocular eye dysfunction in Veterans with Traumatic Brain Injury, specifically to measure ocular accommodation and vergence dynamically. The required system must include the PowerRef 3 device with a medical power adaptor, specific software licenses for dynamic measurements, and a complete measurement set-up kit. Key technical requirements include a minimum sampling rate of 50 Hz, binocular dynamic measurement capabilities, and an open-field optical design using infrared photorefraction technology. The government is specifically seeking information from small businesses under NAICS 339112, though other sources may respond. Interested parties must provide company details, size status, pricing, and evidence of their status as an original equipment manufacturer or authorized distributor. This notice is for planning purposes only and does not constitute a formal solicitation; responses are due by September 8, 2026.

General Info

RFI for PlusOptix PowerRef 3 equipment for VA-ORD study at Cleveland VA Medical Center.

NAICS

339112 - Surgical and Medical Instrument Manufacturing

Place of Performance

VAMC CLEVELAND 10701 EAST BLVD., CLEVELAND, OH, 44106, USA

Set-Aside

SBA

Documents

1

36C25026Q0950 Sources Sought RFI - PowerRef 3 System

DOCX, High priority: read this first8 pages · sources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
Contacts1 person available
OfficeDAYTON, OH, 45428, USA
Office AddressDAYTON, OH, 45428, USA
Contacts
KEVIN PEEPLESCONTRACT SPECIALIST

Full Description

Show more
SOURCES SOUGHT NOTICE
THIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a). DISCLAIMER This request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published. Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement.
SOURCES SOUGHT DESCRIPTION The Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a Accommodation Meter plusoptiX R09 (PowerRef 3) and accessories for Surgical Department Mechanical Room that meets the following:
Product/Items ITEM NO. DESCRIPTION QUANTIYT UNIT OR STOCK NO. Request purchase only of Accommodation Meter plusoptiX R09 (PowerRef 3)
Accommodation Meter plusoptiX R09 (PowerRef 3) incl. Medical Power Adaptor 1 EA 2. Software Licence RP Dynamic measurements of accommodation in sphere, convergence and pupil size changes in scotopic, mesopic and photopic conditions 1 EA 3. Complete measurement set-up kit (includes former MIRROR, SLIDE and REST) 1 EA 4. Shipping and Handling 1 EA
Specifications & Salient Characteristics
Technical Specifications Refraction (vertical meridian): Binocular and monocular measurement Spherical range: +5.00 D to 7.00 D, in increments of 0.01 D Pupil size: Range: 4.0 8.0 mm, measured in 0.1 mm steps, ±10% accuracy Pupil distance (interpupillary distance): Measured in 1.0 mm steps, ±10% accuracy Sampling rate: 50 Hz (one measurement every 20 ms) Measuring distance: Standard working distance of 1 m (± 5 cm) Measurement principle: Binocular, dynamic photoretinoscopy
Interfaces & Power Requirements Interfaces: 4 × USB ports 1 × VGA output (supports 1024 × 768 resolution) Power supply: AC 100 240 V, 50 60 Hz, 2.5 A (excluding monitor)
Environmental Conditions Operating temperature: 10 35 °C (50 92 °F) Storage temperature: 0 50 °C (32 122 °F) Relative humidity (non-condensing): Operating: 20 80% Storage: 10 85%
Data Output & Logging Measurements are continuously recorded into a CSV logfile, capturing: Timestamp (every 20 ms) LED brightness (percentage) Pupil detection status (found/not found) Pupil size (width & height in mm) Pupil brightness (digital units 0 255) Purkinje reflex size & position (pixels: X & Y) Gaze angles (horizontal & vertical in degrees) Spherical refraction per eye, including mean & standard deviation over last 10 frames Interpupillary distance in mm Camera horizontal angle
Salient Functional Characteristics Binocular dynamic measurement: Tracks continuous changes in accommodation (sphere), convergence, and pupil size for both eyes 50 Hz real-time sampling: High temporal resolution enables precise tracking of fast dynamics Open-field fixation: Uses a hot mirror to allow naturalistic visual targets at any distance Non-contact operation: Measurements gathered without touching the subject Research-grade device: Designed specifically for scientific applications investigating accommodation response times, IOL performance, convergence accommodation relationships, and neuro-ophthalmologic metrics
Integration & Output Data can be streamed via USB or recorded to a VGA-connected monitor Outputs are ideal for integration into custom research setups and signal logging systems Salient Characteristics Plusoptix PowerRef 3 Accommodation Measurement System The PowerRef 3 system must meet the following minimum salient characteristics to satisfy clinical research and operational requirements for binocular, real time accommodation and convergence measurement: 1. Measurement Capability Must perform simultaneous binocular measurement of: Refractive state (sphere, vertical meridian) Convergence/vergence Pupil size (both eyes) Must provide continuous, real time data acquisition suitable for dynamic accommodative and vergence analysis. 2. Sampling and Data Output Must provide a minimum sampling rate of 50 Hz (20 ms intervals) to capture rapid accommodation fluctuations. Must support continuous data streaming and export to external computers and research software. Must allow real time or recorded output in spreadsheet compatible formats. 3. Optical and System Design Must use infrared photorefraction technology. Must include an open field optical design, enabling natural fixation on targets at varying distances without the constraints of an enclosed optical path. Must incorporate a hot mirror target presentation system permitting both stationary and moving fixation stimuli at adjustable distances. 4. Calibration and Reliability Must be engineered for long term calibration stability, requiring no routine recalibration under normal use. Must include durable optics and electronics suited for repeated daily research use. 5. Fixation Target Flexibility Must support user selectable fixation targets, including moving or adjustable distance stimuli for controlled accommodation and vergence testing. 6. Integration and Compatibility Must be compatible with standard Windows based data acquisition systems, research platforms, or laboratory PCs. Must allow USB or networked connection for external data handling. 7. System Configuration Must include all necessary hardware, software, cables, and accessories required for full operational use upon installation.
Background: The VA-ORD-funded study Home-based Treatment of Binocular Eye Dysfunction in Veterans with Traumatic Brain Injury (Mark Walker, M.D., principal investigator) will investigate physiological mechanisms underlying near vision impairment in Veterans and will conduct a pilot study to explore the feasibility and potential efficacy of virtual-reality for customized home therapy of convergence insufficiency. This study requires robust measures of ocular accommodation, the change in the shape of the eye s lens to focus on near images. For that purpose, we require a device that can measure directly changes in lens curvature and that can do this dynamically at a high enough sample rate to measure not only the amount but also the rate of accommodation. The device must also have integrated eye tracking for simultaneous measurement of ocular vergence. The PlusOptix PowerRef3 is the only currently available device that measures accommodation directly and dynamically, is portable, and includes eye tracking to measure simultaneous convergence. Scope: Acquisition of an automated retinoscopy-based accommodation and ocular vergence measurement device, its control software, and associated measurement apparatus.    The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and can provide the sought-out supplies/services, please provide the requested information indicated below. Response to this notice should include company name, address, point of contact, DUNS number, and size of business pursuant to the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)
Is your company considered small under the NAICS code identified under this RFI? If not, is your company considered small under a related NAICS code?
Are you the manufacturer or distributor of the items being referenced above (or equivalent product/solution)? What is the manufacturing country of origin of these items?
If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available).
If you re a small business and you are an authorized distributor/reseller for the items identified above (or an equivalent solution), do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified?
Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract type and number.
If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the referenced items/solutions you are providing information for available on your schedule/contract?
Please provide general pricing of your products/solution for market research purposes.
Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to brand name or equal to items to establish capabilities for planning purposes. No re-manufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM. SUBMISSION Responses to this notice shall be submitted via email to contact@example.gov and contact@example.gov referencing 36C25026Q0950 in the email. Telephone responses will not be accepted. Responses must be received no later than September 8, 2026, at 7:00am EST, (Eastern Standard Time). If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this request for information. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. CLAUSES


FAR Number Title Date 52.209-6 PROTECTING THE GOVERNMENT S INTEREST WHEN SUBCONTRACTING WITH CONTRACTORS DEBARRED, SUSPENDED, OR PROPOSED FOR DEBARMENT JAN 2025 52.212-4 CONTRACT TERMS AND CONDITIONS-- COMMERCIAL ITEMS NOV 2023

52.222-90
52.232-33 ADDRESSING DEI DISCRIMINATION BY FEDERAL CONTRACTORS PAYMENT BY ELECTRONIC FUNDS TRANSFER SYSTEM FOR AWARD MANAGEMENT APR 2026
OCT 2018 52.252-2 CLAUSES INCORPORATED BY REFERENCE FEB 1998 52.232-40 PROVIDING ACCELERATED PAYMENTS TO SMALL BUSINESS SUBCONTRACTORS MAR 2023 52.233-1 DISPUTES MAY 2014 52.233-3 PROTEST AFTER AWARD AUG 1996 852.219-76
852.203-70 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING-CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS (DEVIATION)
COMMERCIAL ADVERTISING JAN 2023
MAY 2018 852.232-72 ELECTRONIC SUBMISSION OF PAYMENT REQUESTS NOV 2018 852.237-70 CONTRACTOR RESPONSIBILITIES OCT 2019

PROVISIONS



52.212-1 INSTRUCTIONS TO OFFERORS-COMMERCIAL ITEMS SEP 2023 52.212-2 EVALUATION--COMMERCIAL ITEMS NOV 2021

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 562111
New
Federal
S205--General Waste & Recycling Removal Services - Detroit PoP 04/01/2032
Solicitation # 36C25027Q0022
The Department of Veterans Affairs Network Contracting Office 10 is soliciting quotes for a firm-fixed-price contract to provide general waste and recycling removal services for the John D. Dingell VA Medical Center and Fisher House 99 in Detroit, Michigan. This HUBZone Small Business set-aside procurement, under NAICS code 562111, covers the collection and disposal of non-hazardous municipal solid waste, corrugated cardboard, and construction or bulk waste. The scope specifically excludes regulated medical, hazardous, radioactive, pharmaceutical, and universal waste. The contractor is responsible for providing all labor, vehicles, and equipment, including 34-yard compactor containers and cardboard compactor systems, while responding to Real Time Continuous Monitoring System alerts. The contract features a base period from April 1, 2027, to March 31, 2028, with four subsequent option years extending the performance period through March 31, 2032. Award will be based on the best overall value to the government, with an evaluation focus on past performance. Successful offerors must be registered in the System for Award Management and maintain specific insurance coverages, including 500,000 dollars per occurrence for general liability and 200,000 dollars per person for automobile liability. Invoices must be submitted electronically via the Tungsten Network, and the contractor must adhere to strict quality control and weight verification standards using certified weighing systems.
Solid Waste Collection

POSTED

about 9 hours ago

DEADLINE

in 6 days
View Details
NAICS: 541380
New
Federal
J065--RO Equipment Maintenance
Solicitation # 36C25027Q0051
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for a firm-fixed-price contract to provide preventive and non-routine emergency maintenance services for Reverse Osmosis (RO) equipment systems at the Ann Arbor VA Medical Center. The scope of work covers systems serving the Laboratory Department and Sterile Processing Service, requiring all labor, parts, and supervision to ensure uninterrupted process water operation in accordance with OEM, ST108, and AAMI standards. The anticipated period of performance begins January 8, 2027, and runs through January 7, 2032, consisting of a one-year base period and four one-year option periods. While originally designated as a small business set-aside, Amendment 0001 corrected the requirement to be 100% open market and unrestricted. Award will be based on the most advantageous offer, evaluating technical capability, past performance from the last three years, and total price including all options. Offerors must submit their quotes by November 16, 2026, including a signed SF 1449, a strict adherence to the price schedule, and a technical volume not exceeding ten pages. Contractor personnel are required to complete VA Privacy and Information Security Awareness training and provide all necessary licenses and certifications within three business days of award.
Testing Laboratories and Services

POSTED

about 9 hours ago

DEADLINE

in 19 days
View Details
NAICS: 541620
New
Federal
H941--Chemical Hoods & HEPA PM
Solicitation # 36C25027Q0065
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for the preventive maintenance, inspection, testing, and certification of chemical hoods and HEPA filters at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. This is a combined service contract set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), requiring that no more than 50 percent of the contract value be paid to firms not listed as SDVOSBs or VOSBs. The scope of work includes recurring semiannual and annual certifications, environmental monitoring, and optional condition-based HEPA filter replacements across pharmacy, research, and engineering systems. Performance is scheduled for normal business hours, though off-hours work may be required to avoid disrupting patient care. The contract utilizes a firm-fixed-price structure for both recurring services and optional line items, such as BSC decontamination and ASHRAE 110 tracer-gas testing. A mandatory site visit was scheduled for November 3, 2026, and quotes were due by November 10, 2026. Award evaluation is based on technical rating, price, and past performance. Successful contractors must submit a Quality Control Plan within 10 business days of award and a reconciled electronic inventory within 30 calendar days. All work must adhere to strict regulatory standards, including VHA Directive 1108.12 and USP 797 and 800, with detailed reporting required for acceptance, including raw measurements and unambiguous certification status.
Environmental Consulting Services

POSTED

1 day ago

DEADLINE

in 13 days
View Details
NAICS: 334510
New
Federal
Q403--WatchPat One Direct Program Roudebush VA Medical Center Indianapolis, IN
Solicitation # 36C25027Q0071
The Department of Veterans Affairs, specifically the Richard L. Roudebush Veterans Administration Medical Center in Indianapolis, Indiana, has issued a Notice of Intent to Sole Source for the continuation of the WatchPat One Direct Program. Under solicitation number 36C25027Q0071 and NAICS code 334510, the government intends to negotiate a firm fixed price contract with Veterans Healthcare Supply Solutions (VHSS) based in Jacksonville, Florida. This requirement is being pursued under Simplified Acquisition Procedures and the authority of FAR Part 6.103-1, as the government believes VHSS is the only source capable of meeting the specific needs of the Sleep Lab Department. The scope of work involves providing WatchPat devices that are delivered directly to Veterans' homes for sleep monitoring, with the resulting sleep study reports delivered to clinicians via cloud access. This notice is not a formal solicitation or request for proposals; however, interested parties may submit responses until 3:00 pm on October 29, 2026. To challenge the sole source intent, responses must provide clear and convincing evidence that competition would be advantageous to the government. The primary point of contact for this action is Contract Specialist Ghazal Jones.
Electromedical and Electrotherapeutic Apparatus Manufacturing

POSTED

2 days ago

DEADLINE

in about 22 hours
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS