6680--Loch Raven Boiler Fuel Reserve Tank

Closed
36C24526Q0377Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333914
New
Federal
LOP Fire Protection and Unwatering Pump System
Solicitation # W9127N26QA155
Solicitation W9127N26QA155 is a total small business set-aside for the procurement of a fire protection and unwatering pump system for the Lookout Point Powerhouse in Lane County, Oregon. Issued by the Department of Defense W071 Endist Portland, this firm-fixed-price requirement is necessitated by a deep reservoir drawdown that would otherwise disable critical service water and fire protection systems. The scope of work includes the delivery of a 650 GPM vertical pump/motor assembly, a 0.25 HP jockey pump system, a fire pump controller panel, overload protection, and various piping and fitting components. All equipment must meet AWWA E103 and HI 9.1-9.5 standards, with a delivery deadline of March 1, 2027, shipped FOB destination to Lowell, Oregon. The government will award a single purchase order based on an evaluation of technical compliance, past performance, and price, utilizing the HUBZone price evaluation preference. Offerors must be registered in the System for Award Management under NAICS code 333914 and submit a complete quote package via email to the designated point of contact. The solicitation underwent two amendments, with the final response deadline extended to September 11, 2026. Key contractual requirements include compliance with MIL-STD-129 for marking, DFARS cybersecurity and telecommunications regulations, and specific pump acceptance criteria according to HI ANSI/HI 14.6 grade 2B.
W071 Endist Portland

POSTED

1 day ago

DEADLINE

in 2 days

AI Contract Overview

Show more

The contract involves the procurement and installation of a 6,000-gallon reserve fuel tank to support the boiler system at the Loch Raven VA property. This new fuel tank will serve as a supplemental reserve alongside the existing fuel tank and will be installed on the current asphalt drive lane next to the emergency generator. The scope of work includes delivery of the tank, installation, connection to the fuel line, and securing the tank area to ensure proper and safe operation. This contract is a total small business set-aside under the NAICS code 333914 and is issued by the Department of Veterans Affairs through the NETWORK Contract Office 5, based in Linthicum, Maryland. The solicitation was posted on March 23, 2026, with a response deadline of March 30, 2026. Theresa Thomas serves as the Contracting Officer and primary point of contact. The project aims to enhance the fuel storage capacity at the VA site to maintain reliable boiler operation essential for facility functions.

General Info

Procurement and installation of 6,000-gallon fuel tank at Loch Raven VA to support boiler system.

Agency

Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)View Agency

Contract Value

$79,500

NAICS

333914 - Measuring, Dispensing, and Other Pumping Equipment ManufacturingView NAICS

Place of Performance

Loch Raven MD VA Medical Center 3901 Loch Raven Blvd, MD, USA

Set-Aside

SBA

Awardee

DATANET ENGINEERING, INC.View Profile

Award Issued Date

Documents

(8)

36C24526Q0377_4.docx

DOCX

36C24526Q0377_3.docx

DOCX

36C24526Q0377_1.docx

DOCX

36C24526Q0377+Reserve+Fuel+Tank.pdf

PDF

Amendment to Solicitation 36C24526Q0377 - Loch Raven Boiler Fuel Reserve Tank

DOCXamendment

Loch+Raven+Diagram+for+Boiler+Fuel+Reserve_3.24.26.pdf

PDF

36C24526Q0377_2.docx

DOCX

image.png

PNG

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

4 updates
PhaseClosed
Posted

Combined Synopsis

Amendment 1

Contract was updated

Amendment 2

Contract was updated

Amendment 3

Contract was updated

Amendment 4

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Organization / Agency
Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
View Agency Profile
Office AddressLINTHICUM, MD, 21090, USA
Contacts
Theresa ThomasContracting Officer

Full Description

Show more
AMENDMENT TO SOLICITATION - 36C24526Q0377
It is being added to the STATEMENT OF WORK **The contractor must provide a 1 thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2 radially from the support to distribute the load.**
B.2 STATEMENT OF WORK LR Boiler Reserve Fuel Tank
SCOPE OF WORK: The purpose of this project is to purchase and install a 6,000-gallon reserve fuel tank to support the boiler at the Loch Raven VA property. The fuel tank will supplement the existing reserve fuel tank and be placed on the existing asphalt drive lane adjacent to the emergency generator. The project includes delivery, installation, fuel line connection, and securing the tank area. Delivery and Installation of Fuel Tank: Provide and install a new UL 142 double-wall steel 6,000-gallon, 8 ft diameter skid-mounted aboveground storage tank (AST). The tank will include all required components and fittings such as venting, manway lid, spill bucket, overfill control valve, stick port, visual level gauge, and anti-siphon control. The tank will be white and have all required labels and signage.
Fuel Piping Installation: Install 1-inch supply and return piping with all required valves and fittings. Support the piping properly and connect it to the existing piping outside the building at the sump.
Fuel Delivery: The owner will provide a fuel delivery to the tank. Installation of Concrete Barriers: Install six (6) traffic barriers to protect the tank. The barriers will be placed on the asphalt adjacent to the tank and spaced out to provide access to the tank. Secured Perimeter Installation: Install a 6 ft construction fence around the tank. One section of the fence will be designed to open for tank access.
Integration with Existing Monitoring System: Install a refurbished probe with a diesel and water float kit. Install all wiring and conduit in compliance with the manufacturer s recommendations and the National Electric Code. Install an interstitial sensor in the tank secondary along with all necessary wiring and connections. Program the existing Veeder Root console to monitor the diesel probe and sensor. Program the overfill alarm to activate at 90% capacity, providing overfill protection for the new 6,000-gallon diesel tank. **The contractor must provide a 1 thick steel road plates to be placed under the tank supports. Plates to extend out approximately 2 radially from the support to distribute the load.** DELIVERABLES: 6,000-Gallon Tank Installation: UL 142 double-wall steel tank, including all required fittings and components. Secure fencing and traffic barriers to protect the tank.
Fuel Piping: Installed supply and return piping with necessary and compatible valves and fittings. Monitoring System Integration: Refurbished probe with diesel and water float kit. Installed interstitial sensor and all necessary wiring. Programmed Veeder Root console for monitoring and overfill protection.
Responsibilities: Contractor: Responsible for the delivery and installation of the fuel tank and associated components. Responsible for installing the piping, barriers, and fencing. Responsible for integrating the tank with the existing Veeder Root monitoring system. The tank will be installed directly on the existing asphalt driveway. All work is to be performed in compliance with relevant regulations and safety standards.
EVALUATION FACTORS: Vendor must be registered in SAM.gov; all bid quotes must provide a letter of authorization to distribute supplies on a letterhead from manufacturer; Best Value; Delivery Lead times stated; complete BAA certificate.

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 339112
New
Federal
SPS Sterilizer
Solicitation # 36C24526Q0758
Solicitation 36C24526Q0758 is a Firm-Fixed Price purchase order for the procurement and installation of five new steam sterilizers and five switch-over control systems for the Sterile Processing Service at the Baltimore VA Medical Center. The project includes the de-installation and disposal of existing equipment, facility work such as plumbing relocation and flooring leveling, and system validation performed by an OEM-trained representative. To ensure continuous operations, installation must be completed in two phases, with the first two units installed followed by the remaining three. While Belimed is the brand name of reference, the government will accept fully equivalent systems that meet specific dimensions and a minimum chamber volume of 275 liters. The award will be granted to the responsible quoter determined to be most advantageous based on technical capability, price, and past performance. Mandatory submission requirements include a detailed line-item worksheet, manufacturer authorization letters for distributors, and specific certifications regarding Service Contract Labor Standards. Delivery must be FOB Destination and completed within 12 months of the award. Contractors are required to maintain general liability insurance of 500,000 dollars per occurrence and comply with strict security prohibitions regarding covered telecommunications equipment. Invoices are to be submitted electronically in arrears upon the receiving and acceptance of goods and services.
Surgical and Medical Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 2 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS