Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on May 7, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

678 Medical Refrigerator

Closed
36C26225Q0879Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

Tucson, AZ, 85723, USA

Set-Aside

NONE

Documents

1

36C26225Q0879 - 678 Medical Refrigerator Sources Sought

DOCX, High priority: read this firstsources-sought
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)
Contacts1 person available
OfficeGilbert, AZ, 85297, USA
Office AddressGilbert, AZ, 85297, USA
Contacts

Full Description

Show more
THIS REQUEST FOR INFORMATION (RFI) / SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION. SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT/RFI DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 333415 (size standard of 1,250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published. The Department of Veterans Affairs (VA) Tucson Healthcare System Pharmacy Service is seeking sources capable of providing Medical Grade Refrigerators. The list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. STATEMENT OF WORK (SOW) Contract Title: TUC-678-25-3-071-0104 FOLLET PHARMACY REFRIGERATOR REPLACEMENT Background: Replacing current equipment that is past the life expectancy needed for functionality in the pharmacy department. Biomedical suggested that the old units be replaced. Labor and parts are out of warranty and no longer supported by the manufacturer. If refrigerators go down, it will take a long time to fix and find replacements with contents of medications and vaccines totaling a value of excess a million dollars we cannot take the risk in storing the medications in unsupported refrigerators. This equipment request has been approved by the equipment committee to move forward with purchase due to the life expectancy exceeding the manufacture warranty and recommended use of life. Scope: To ensure this units get replaced prior to having any of the refrigerators go down, causing stored medications to be compromised. These refrigerators are calibrated to meet the required temperature to ensure the medication being stored is within guidelines. These medications are costly, so if these are compromised, this will create additions costs to the facility to replace needed on hand supplies. Specific Tasks: Deliver shall be completed within 30 days of award. Equipment must be delivered secure and strapped to pallets. Deliver location is warehouse 14 at the address provided in this SOW. Deliverables: CLIN Description Qty UOM 0001 Infinity Series 24.6 cu ft capacity full size medical grade refrigerator, Follett Part# REF25i-4S-R0000G or equal to medical grade refrigerator 6 EA 0002 Infinity Series upright refrigerators with variable capacity compressor 24.6 cu ft, Follett Part# REF25i-6B-R0000G or equal to medical grade refrigerator 6 EA NOTE: Potential offers must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are - or equal, a description of the salient characteristics is outlined below. The FAR Clause 52.211-6 Brand Name or Equal applies to this acquisition. Offeror quotations must demonstrate meeting the salient physical, and functional characteristics included in this solicitation, otherwise, they will be considered non-responsive and not considered for award. Salient Characteristics: Infinity Series 24.6 cu ft capacity full size medical grade refrigerator, Follett Part# REF25i-4S-R0000G or equal to Medical grade refrigerator x 6EA Must be medical grade refrigerator. Must be certified to meet NSF/ANSI 456 standards for vaccine storage purposes. Must have a minimum of 24.6 cubic feet capacity. Must have a touchscreen and display temperature and integral alarming functions. Users must have an option to change display temperature to C or F. Must have integral data and even logging capability. Must have a lock option. Must have glass doors so users can see the content inside of the refrigerator for easy access. Must be configured with right-hinged glass door. Must have a minimum of four (4) epoxy-coated shelves for durable and resistant shelving. Sound level must not exceed 40 dBA to avoid noise pollution in hospital environment. Must ENERGY STAR certified for efficient energy use. Must have a modular refrigeration system with a variable capacity compressor and microprocessor controller to control stable and consistent temperature throughout each cabinet with minimal fluctuation of - 1 C (1.8 F) temperature. Must have energy-efficient LED lights necessary for energy efficiency and maintaining a cooler temperature. Must have a minimum of three (3) shelves inside of refrigerator. Must have stainless steel cabinet to provide precise temperature control, plus provides high corrosion resistance, and hygiene, making it important for safe and cost-effective operations in hospitals. Must have a front-face turn air circulation to maintain consistent internal temperatures, reducing moisture buildup and promotion content preservation. Must have a minimum of six (6) drawers inside of refrigerator Drawers must be stainless steel for corrosion resistance, strength, and ease of cleaning and sterilization in hospital environment. Drawers must have full extension shielded roller bearings and stainless S-tracks to making moving appliances sage and easy. Must come with Omnicell compatible door bracket. Must have medDISPENSE compatible door bracket. Must come with Glycerine for temperature monitoring and to prevent ice build-ups. Must come with a seismic anchoring for safety and to resist the forces exerted by earthquakes. Must have DicksonOne VFC-compliant freestanding display data logger with Wi-Fi and Ethernet capability for use. Must have ambient temperature and humidity sensor for use with DicksonOne freestanding display and touchscreen data loggers. Infinity Series upright refrigerators with variable capacity compressor 24.6 cu ft, Follett Part# REF25i-6B-R0000G or equal to medical grade refrigerator x 6EA Must be medical grade refrigerator. Must be certified to meet NSF/ANSI 456 standards for vaccine storage purposes. Must be - upright style refrigerator. Must have a minimum of 24.6 cubic feet capacity. Must have a minimum of six (6) drawers. Drawers must be epoxy-coated - floating basket types for durable and resistant. Drawers must be fully extended for its use. stainless steel drawers must be shielded with roller bearings and stainless S-tracks in order to move appliances sage and easy). Must have an LCD capacitive touchscreen with user selectable C or F. Must have Integral data and event logging, user-programmable temperature display and integral alarming functions Sound level must not exceed 40 dBA to avoid noise pollution in hospital environment Must ENERGY STAR certified for efficient energy use. Must have a modular refrigeration system with a variable capacity compressor and microprocessor controller to control stable and consistent temperature throughout each cabinet with minimal fluctuation of - 1 C (1.8 F) temperature. Must have energy-efficient LED lights necessary for energy efficiency and maintaining a cooler temperature. Must have stainless steel cabinet to provide precise temperature control, plus provides high corrosion resistance, and hygiene, making it important for safe and cost-effective operations in hospitals. Must have a front-face turn air circulation to maintain consistent internal temperatures, reducing moisture buildup and promotion content preservation. Must have a minimum of three (3) shelves. Must come with Omnicell compatible door bracket. Must have medDISPENSE compatible door bracket. Must come with Glycerine for temperature monitoring and to prevent ice build-ups. Must come with a seismic anchoring for safety and to resist the forces exerted by earthquakes. Must have DicksonOne VFC-compliant freestanding display data logger with Wi-Fi and Ethernet capability for use. Must have ambient temperature and humidity sensor for use with DicksonOne freestanding display and touchscreen data loggers. Packaging, Packing and Shipping Instructions: Packaging to include all user guides and manufacturer cleaning instructions. Must be delivered with secure measures to ensure no damage occurs to the fragile equipment. Inspection and Acceptance Criteria: Equipment must be brand new and in good working order Place of Performance: Department of Veterans Affairs Tucson Healthcare System Warehouse 14 3601 S. 6th Ave Tucson, Az 85746 Delivery Schedule: 30 days after award If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: (1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SOW requirements. For instances where your company cannot meet the SOW requirement(s), please explain. For instances where your company can meet the SOW requirement(s), please show how your company meets/exceeds each requirement. (2) Please review the list of SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A. (3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc. (4) Is your company considered small under the NAICS code identified in this RFI? (5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SOW? (6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available). (7) If you're a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified. (8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR - 125.6? (9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items? (10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? (11) Please indicate whether your product conforms to the requirements of the Buy American Act? (12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate. (13) What is estimated life span of your solution? What support/services does that entail? (14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained. (15) Does your organization offer a leasing solution? Please elaborate. (16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s). (17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract. (18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (19) Please provide your SAM.gov Unique Entity ID/Cage Code number. Responses to this notice shall be submitted via email to contact@example.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, May 14, 2025 by 10:00 PM Pacific Local Time. All responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.

More opportunities from Department Of Veterans Affairs → 262-NETWORK Contract Office 22 (36C262)

Same awarding agency

NAICS: 562211
New
Federal
F999--Hazardous Material & Waste Disposal
Solicitation # 36C26227Q0071
The Department of Veterans Affairs, through Network Contracting Office 22, has issued a sources sought announcement under solicitation number 36C26227Q0071 to identify qualified contractors for hazardous material and waste management services. This is a market research effort and not a formal solicitation for award. The scope of work involves providing all labor, materials, equipment, and transportation for hazardous waste disposal, collection, and emergency response services. Performance will take place at the Greater Los Angeles VA Healthcare System West LA Main Campus and various Community Based Outpatient Clinics, including locations in San Gabriel Valley, Santa Barbara, Santa Maria, San Luis Obispo, Bakersfield, and the Captain Rosemary Bryant Mariner clinic. The acquisition is classified under NAICS code 562211 for Hazardous Waste Treatment and Disposal, with a size standard of 47.0 million dollars. In accordance with Public Law 109-461, the government is considering a total set-aside for Service-Disabled Veteran Owned Small Businesses, though it may opt for alternate set-asides or full and open competition based on the responses received. Interested firms must be registered in the System for Award Management and, if applicable, the SBA VetCert system. To be considered, respondents must submit a capability statement detailing their qualifications and past performance from the last five years, along with a completed price schedule for market research purposes. All submissions must be emailed to the contract specialist by November 6, 2026.
Hazardous Waste Treatment and Disposal

POSTED

about 17 hours ago

DEADLINE

in 9 days
View Details
NAICS: 811111
New
Federal
Yuma Mobile Vet Center (MVC) Repair
Solicitation # 36C26227Q0055
The Department of Veterans Affairs, through the Southern Arizona Health Care System, is soliciting quotes for a firm-fixed-price service contract to perform non-mechanical body repairs on Mobile Vet Center 0828. The scope of work involves repairing cosmetic and potential structural damage to the driver's rear side, including the removal and replacement of damaged body panels, decals, and the body wrap. The selected contractor will be responsible for repainting repaired surfaces to match the existing finish and providing a craftsmanship warranty on all work. Performance will take place in Tucson, Arizona, with a base period of performance from December 1, 2026, to November 30, 2027. This opportunity is a total Small Business Set Aside, and the government will evaluate offerors based on their service-disabled Veteran-owned or Veteran-owned small business certification status and their intent to use such entities as subcontractors. Proposals must be submitted by November 9, 2026, at 11:00 am. A site visit is scheduled for November 3, 2026, in Tucson. To be eligible for award, offerors must provide a signed certification regarding limitations on subcontracting and represent compliance with FASCSA and telecommunications prohibitions. Payments will be processed via Electronic Funds Transfer through the System for Award Management.
General Automotive Repair

POSTED

about 17 hours ago

DEADLINE

in 12 days
View Details
NAICS: 335910
New
Federal
6135--UPS Battery Replacement
Solicitation # 36C26227Q0064
Solicitation 36C26227Q0064 is a firm fixed price request for quotes for the replacement of 60 UPS batteries at the San Diego VA Medical Center, specifically within Building 1 Room BB100-1. This project is a total small business set-aside under NAICS code 335910, with a size standard of 1,250 employees. The scope of work requires the contractor to transition the system to maintenance bypass, implement lock out/tag out procedures on the primary feed, install 60 C&D UPS12-545PLP batteries, and dispose of old batteries at an approved hazardous waste facility. Deliverables include a service report in both hard and electronic copies, a three-year manufacturer warranty, and a one-year installation warranty. All battery terminals must be tightened to a torque specification of 60 In-Lbs. The period of performance is 365 days from the date of award. Offerors must submit their quotes via email to the contracting officer by 15:00 Pacific Local Time on November 10, 2026. Required submission documents include a completed SF 1449 with the vendor's SAM UEI number, a schedule of supplies identifying the specific manufacturer and model, and a certificate of compliance regarding subcontracting limitations. Invoicing must be processed exclusively through the Tungsten Network. The government reserves the right to evaluate offers without discussions and may award to other than the lowest bidder if it is in the public interest.
Battery Manufacturing

POSTED

about 17 hours ago

DEADLINE

in 16 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS