Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 5, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

7320--542-24-1-483-0037 | Restaurant Supply Refrigerators | NCO 4 Commodities 1 (VA-24-00043122)

Closed
36C24424Q0467Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
Federal
NSWCCD York Chill Pump Replacement
Solicitation # N0016727Q1002
The Naval Surface Warfare Center, Carderock Division (NSWCCD) is soliciting quotes for the procurement, delivery, and turn-key installation of a replacement pump (Pump No. 1) for York Chiller No. 1 in Building 157. This equipment is critical for providing chilled-water cooling to the Building 13 Server Rooms. The project requires the removal of the damaged pump and the installation of a York Chill Pump, Model YLAA0080SJ46X, Serial SEMM-609950. Due to the proprietary nature of the equipment, the contractor must utilize certified Johnson Controls technicians or representatives. The installation must be completed on or before December 18, 2026, at the NSWCCD facility in Bethesda, Maryland. This is a brand-name restricted procurement under full and open competition and is not set aside for small businesses. The government intends to award a single firm-fixed-price purchase order based on the lowest price technically acceptable method, evaluating quotations on a pass/fail basis for technical requirements and considering past performance via the Supplier Performance Risk System. All quotes must be submitted on official company letterhead, including all-inclusive pricing and business size, and sent via email to the contract specialist and contracting officer by 09:00 AM EDT on November 06, 2026. The contract includes specific requirements for item unique identification per MIL-STD-130 and electronic invoicing through the Wide Area WorkFlow system.
Nswc Carderock

POSTED

about 12 hours ago

DEADLINE

in 18 days
NAICS: 333415
New
DIBBS
41--COOLER UNIT,AIR
Solicitation # SPE8E8-27-T-0446
Solicitation SPE8E8-27-T-0446 is a Request for Quotations issued by DLA Troop Support, Construction and Equipment for the procurement of one air cooler unit, identified by NSN 4130-01-225-1590 and Engineered Coil Company part number FCU-H3-3.5KW-LVP. The requirement is categorized under NAICS code 333415 and is designated as a critical application item. Quotations must be submitted via the DIBBS portal by November 9, 2026. The delivery is specified as FOB Origin with a required delivery date of October 19, 2027, and a lead time of 153 days after order. The item is to be shipped to the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The contract mandates strict adherence to technical and quality requirements found in the DLA Master List, as well as packaging and marking standards MIL-STD-2073-1E and MIL-STD-129. Special environmental restrictions prohibit the intentional addition of mercury or mercury-containing compounds, except in specific functional applications. Inspection and acceptance will occur at the destination per FAR 52.246-1. Administrative requirements include the use of the Wide Area WorkFlow system for invoicing and compliance with various FAR and DFARS clauses regarding the Buy American Act, cybersecurity safeguarding of covered defense information, and the prohibition of covered defense telecommunications equipment.
DDSP NEW CUMBERLAND FACILITY

POSTED

about 12 hours ago

DEADLINE

in 10 days

General Info

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

Corporal Michael J. Crescenz VA Medical Center 3900 Woodland Ave, Philadelphia, PA, 19104, USA

Set-Aside

SBA

Documents

1

36C24424Q0467 - Restaurant Supply Refrigerators

DOCX, Low priorityrfi
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)
Contacts1 person available
OfficePITTSBURGH, PA, 15215, USA
Office AddressPITTSBURGH, PA, 15215, USA
Contacts
Olivia OsborneContract Specialist

Full Description

Show more
This is Not a Solicitation Announcement. This is a Request for Information Only. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Since this is Request for Information announcement, no evaluation letters and or results will be issued to respondents. No solicitation exits. Therefore, do no request a copy of the solicitation. The Department of Veterans Affairs VISN 4, Network Contracting Office 4 (NCO 4), is seeking information and potential qualified/verified Small Businesses capable of meeting requirement and salient characteristics below to provide Coatesville VAMC Mental Health Services with a variety of ten (10) new commercial refrigerator and refrigerator/freezers. Commercial Refrigeration for Domiciliary Services Coatesville VAMC MH Services 1. Background: The Coatesville VAMC located at 1400 Blackhorse Hill Rd, Coatesville, PA, provides outpatient, inpatient and skilled nursing services to veterans residing with the medical center s 3 county catchment area in Southeastern Pennsylvania. The Mental Health domiciliary and acute Mental Health unit provide MH services to Veterans in need of acute or longer-term care. 2. History of the Requirement: Our programs require refrigeration units to keep patient foods and drink at specific temperatures based on federal guidelines. Previous purchases of refrigeration units for the programs were more residential in nature and were not robust enough to maintain the temperatures needed when the units were opened repeatedly. Our service was tasked with identifying commercial equipment that would meet our specifications and maintain a safe environment for the patient s food and drink. Some of these pieces are replacements for failed units and some are additional units to increase the space for storing food and drink. 3. Summary of the Requirement: The Coatesville VAMC has a new requirement for the purchase a variety of ten (10) new commercial refrigerator and refrigerator/freezers, brand name or equal to the Everest Refrigeration units listed below, to be distributed among our residential domiciliary and acute MH unit. These will be used to store food and drink designated for the patients in a safe manner. Request to include installation of the units in specified locations and the removal of all packaging materials. 4. Description of requirements: Four (4) ETBR1 7 Cu. Ft. Undercounter Refrigerators or Equal Locations Bldg 8 Rooms 125D and 204, Bldg 39 Rooms 124 and 204 Dimensions not to exceed 27.75 wide by 35.25 high with casters by 31.5 deep Top Mounted Blizzard R404A condensing unit for ease of replacement Electronically commutated fan motors to achieve fast cooling with less energy consumption Full length air duct system to ensure optimal circulation of cold air Required temperature range performance - Refrigerator must be able to maintain constant temperature below 41° F. Audible overheat alarms for compressor and condenser coil LED Lighting to provide bright illumination with low heat generation Snap in magnetic door gaskets for easy cleaning and replacement High strength, recessed door handles Pre-wired and ready to plug in Auto defrost cycles for seamless operation High performance condenser to support rapid temperature stabilization Adjustable shelving Multifunction digital controller with LED display 7 cu. ft. storage capacity Self-maintaining condensate pan requiring no external drains Two (2) ESFRH2 22 Cu. Ft. Refrigerator/Freezer or Equal Locations Bldg 8 Room 125D, Bldg 39 Room 113C Dimensions not to exceed 29.25 wide by 79.25 high with casters by 31.5 deep Top Mounted Blizzard R404A condensing unit for ease of replacement Electronically commutated fan motors to achieve fast cooling with less energy consumption Full length air duct system to ensure optimal circulation of cold air Required temperature range performance - Refrigerator must be able to maintain constant temperature below 41° F. Freezer must be able to maintain constant temperature below 0° F. Audible overheat alarms for compressor and condenser coil LED Lighting to provide bright illumination with low heat generation Snap in magnetic door gaskets for easy cleaning and replacement High strength, recessed door handles Pre-wired and ready to plug in Auto defrost cycles for seamless operation High performance condenser to support rapid temperature stabilization Adjustable shelving Multifunction digital controller with LED display 11 cu. ft. storage capacity freezer, 11 cu. ft. refrigerator Self-maintaining condensate pan requiring no external drains Separate temp controls for the freezer and the refrigerator Self-closing doors to ensure doors are not accidentally left open Two (2) ESR1 23 Cu. Ft. Refrigerator or Equal Locations Bldg 59 Room 139, Bldg 39 Room 127B Dimensions not to exceed 29.25 wide by 79.25 high with casters by 31.5 deep Top Mounted Blizzard R404A condensing unit for ease of replacement Electronically commutated fan motors to achieve fast cooling with less energy consumption Full length air duct system to ensure optimal circulation of cold air Required temperature range performance - Refrigerator must be able to maintain constant temperature below 41° F. Audible overheat alarms for compressor and condenser coil LED Lighting to provide bright illumination with low heat generation Snap in magnetic door gaskets for easy cleaning and replacement High strength, recessed door handles Pre-wired and ready to plug in Auto defrost cycles for seamless operation High performance condenser to support rapid temperature stabilization Adjustable shelving Multifunction digital controller with LED display 23 cu. ft. storage capacity Self-maintaining condensate pan requiring no external drains Two (2) ESWQ3 52 Cu. Ft. Refrigerator-Freezer or Equal Locations Bldg 8 Room 232, Bldg 39 Room 221 Dimensions not to exceed 59 wide by 79.25 high with casters by 31.5 deep Top Mounted Blizzard R404A condensing unit for ease of replacement Electronically commutated fan motors to achieve fast cooling with less energy consumption Full length air duct system to ensure optimal circulation of cold air Required temperature range performance - Refrigerator must be able to maintain constant temperature below 41° F. Freezer must be able to maintain constant temperature below 0° F. Audible overheat alarms for compressor and condenser coil LED Lighting to provide bright illumination with low heat generation Snap in magnetic door gaskets for easy cleaning and replacement High strength, recessed door handles Pre-wired and ready to plug in Auto defrost cycles for seamless operation High performance condenser to support rapid temperature stabilization Adjustable shelving Multifunction digital controller with LED display 13 cu. ft. storage capacity freezer, 39 cu. ft. refrigerator Self-maintaining condensate pan requiring no external drains Separate temp controls for the freezer and the refrigerator Self-closing doors to ensure doors are not accidentally left open 5. Incidental Services: The Contractor will be responsible for delivering the units to the specified locations and removing all packing materials. 6. Installation Requirements: Contractor installation will include the following: Contractor will deliver each unit to the specific location. Contractor will place the unit inside the specified room and assemble there. Contractor will make sure the unit is running properly before leaving. Contractor will not be responsible for removing current refrigeration units; they will leave their units off to the side of the current units. Contractor will remove all packing materials associated with the delivery and remove from the VA facility. Contractor will ensure tools are always kept under the control of the contractor s staff and ensure all tools are accounted for when leaving each area. Responses to this RFI should include company name, address, point of contact, phone number, and point of contact e-mail, DUNS Number, Cage Code, size of business pursuant to North American Industry Classification code (NAICS) 333415, Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing, The Small Business Size Standard for this NAICS code is 1,250 employees. Please answer the following questions: (1) Please indicate the size status and representations of your business in accordance with the NAICS code _______, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.) (2) Is the required equipment available on a Federal Supply Schedule or Government Wide Acquisition Contract? If so, please include the schedule number. (3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? If not, provide additional information shown below. This is to confirm compliance with the non-manufacturer rule IAW 13 CFR 121.406(b) Nonmanufacturers. Does your company exceed 500 employees Primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied; - Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice; - Provide the items of a small business (4) If your company is a large business, do you have any authorized small business distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (5) If your company is a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (6) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to sub contracted work and completion of job. (7) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award. (8) Please submit your capabilities in regard to the salient characteristics detailed above and any information pertaining to equal to items to establish capabilities for planning purposes? (9) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. (10) Please provide your UEI number. *** Submissions addressing number (10) should show clear, compelling and convincing*** evidence that all equal to items" meet all the salient characteristics. This RFI will be conducted in accordance with Federal Acquisition Regulation (FAR) Part 13. Telephone responses will not be accepted. Responses must be received via email to Contract Specialist contact@example.gov no later than 2:00 PM Eastern Standard Time on March 12, 2024. This notice will help the VA in determining available potential sources only. - Do not contact VA Medical Center staff regarding this requirement, as they are not authorized to discuss this matter related to this procurement action. All firms responding to this Request for Information are advised that their response is not a request for proposal, therefore will not be considered for a contract award. - If a solicitation is issued, information will be posted on Contract Opportunities web site for all qualified interested parties at a later date and interested parties must respond to the solicitation to be considered for award. - This notice does not commit the government to contract for any supplies or services. - The government will not pay for any information or administrative cost incurred in response to this Request for Information. - Information will only be accepted in writing by email to Contract Specialist Olivia Osborne, at contact@example.gov. - DISCLAIMER - This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. - Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. - Responders are solely responsible for all expenses associated with responding to this RFI.

More opportunities from Department Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)

Same awarding agency

NAICS: 325412
New
Federal
6505--INTENT TO SOLE SOURCE Radiopharm - Lutathera & Pluvicto - Lebanon VAMC
Solicitation # 36C24427Q0045
The Department of Veterans Affairs, Network Contracting Office 4, intends to establish a firm-fixed-price contract for the procurement and delivery of name-brand Lutathera and Pluvicto radiopharmaceuticals for the Lebanon VA Medical Center. The scope of work includes the distribution, transportation, and inventory management of 8 doses of Lutathera and 48 doses of Pluvicto, both at 200mCi intravenous injection. The proposed period of performance is from January 1, 2027, to December 31, 2027. The government intends to sole source this requirement to Novartis Pharmaceuticals Corporation under the Revolutionary FAR Overhaul (RFO) for FAR 8.4 and GSAM/R 538.71, in accordance with Executive Order 14275. The contractor must be licensed by the Nuclear Regulatory Commission and comply with FDA, OSHA, and DOT regulations, including the use of lead-shielded containers and specific labeling requirements such as bar-coding for dose tracking. Deliveries must be made F.O.B. Destination to the Lebanon VA Medical Center, with routine shipments arriving at least one hour before calibration time. Preference will be given to contractors utilizing non-High Enriched Uranium sources. This notice is for planning purposes, and interested vendors must submit a one-page capability statement, including their SAM UEI number and socioeconomic category, to the Contracting Specialist by November 3, 2026, at 14:00 PM EST. The procurement falls under NAICS code 325412 with an SBA size standard of 1,300 employees.
Pharmaceutical Preparation Manufacturing

POSTED

about 12 hours ago

DEADLINE

in 5 days
View Details
NAICS: 339112
New
Federal
6515--Full Body Phototherapy
Solicitation # 36C24427Q0046
The Department of Veterans Affairs is conducting market research through a Sources Sought Notice to identify qualified sources for the one-time acquisition of one full body clinical phototherapy cabinet for the Wilmington VA Medical Center in Delaware. The equipment is intended for treating dermatologic conditions such as psoriasis, vitiligo, and eczema. Key technical requirements include a minimum operational lifespan of five years, a minimum one-year manufacturer service warranty, and the ability to support narrowband UVB, UVA, and combination therapies. The unit must feature forty-eight high-intensity six-foot ultraviolet lamps, an integrated dosimetry system, a touchscreen interface, and a temperature-management system with patient-controlled cooling. Additionally, the cabinet must be wheelchair accessible, include ultraviolet-transmitting acrylic shields, and maintain treatment history locally without requiring connection to the VA network. Vendors must also offer yearly maintenance services as part of their commercial catalog. This notice is for market research purposes only and does not constitute a binding offer or a formal solicitation. Interested respondents must submit their company details, SAM UEI number, business size classification, and any existing government contract vehicles to the designated point of contact by 6:00 am ET on November 10, 2026. The acquisition falls under NAICS code 339112 with a size standard of 1,000 employees. Small businesses must demonstrate compliance with the nonmanufacturer rule and provide a letter of authorization from the original equipment manufacturer if acting as a distributor. Large businesses are required to disclose any designated distributors. Responses should include capability materials such as brochures or hyperlinks to help the government determine the technical capabilities of the proposed equipment.
Surgical and Medical Instrument Manufacturing

POSTED

about 12 hours ago

DEADLINE

in 11 days
View Details
NAICS: 561730
New
Federal
S218--Snow Removal Services Wilmington VAMC
Solicitation # 36C24427Q0O12
Solicitation 36C24427Q0012 is a combined synopsis and request for quote for snow removal and deicing services at the Wilmington VAMC in Delaware. This is a five-year Indefinite Delivery/Indefinite Quantity (IDIQ) contract with an anticipated period of performance from December 1, 2026, through November 30, 2031. The contract has a minimum guarantee of 5,000 dollars and an estimated maximum value of 500,000 dollars, with funds obligated via individual task orders. The procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 561730. The scope of work includes clearing all levels of a multi-level parking garage, stairwells, entrances, and exposed ramps, with a requirement that all areas be cleared by 6:00 AM EST following overnight snowfall. Specific chemical restrictions are in place, prohibiting rock salt in the garage and requiring the use of garage-friendly chemicals such as sodium acetate, potassium acetate, or calcium magnesium acetate. The contractor must provide an on-site supervisor for every operation and ensure personnel wear OSHA-required PPE and high-visibility vests. Performance will be evaluated based on a Quality Assurance Surveillance Plan, and the award will be based on a comparative evaluation of technical capability and past performance, as well as price. Offerors must be registered in the System for Award Management and submit their quotes via email to the designated contract specialist. Submissions must include a technical document not exceeding 20 pages, firm fixed pricing for all line items, and three examples of past performance for similarly scoped work. Invoices are to be submitted electronically in arrears upon job completion and are due within 30 days. Compliance with applicable wage and hour laws and limitations on subcontracting are mandatory for the prime contractor.
Landscaping Services

POSTED

3 days ago

DEADLINE

in 4 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS