Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity was posted on August 25, 2011. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

99--OSHA Compliant Lockout / Tagout

Awarded
VA24611RQ0337Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Department of Veterans Affairs Medical Center in Salem, Virginia, is seeking a contractor to develop a comprehensive Lockout procedure and placard system that meets or exceeds OSHA Standard 1910.147. The selected provider must utilize equipment surveyors experienced in OSHA standards and machinery to locate, survey, identify, label, and document hazardous energy sources. Requirements include the use of ANSI color-coded icons for different energy types, the identification of primary, secondary, and stored energy sources, and the inclusion of Arc Flash identifiers for PPE awareness. Deliverables must include Lockout Placards created in Microsoft Word and provided in original electronic format, featuring plan views of equipment, energy source locations, the number of locks required for zero energy, and a yearly audit checkbox. Additionally, the contractor must provide energy source tags detailing magnitude and verification procedures, along with simple step-by-step instructions for disconnecting energy sources. This is a one-time service procurement with no option years, requiring interested firms to submit their company details, socioeconomic status, and relevant experience in medical or clinical settings.

General Info

Agency

N/A

Contract Value

$31,850

NAICS

541330 - Engineering Services

Place of Performance

WV, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Sources Sought

Notice updated

Response deadline changed from Jul 1, 2011 to Aug 5, 2011. The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyN/A
ContactsNo contacts available
OfficeN/A
Organization / Agency
N/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
The Department of Veterans Affairs Medical Center, Salem, Virginia (VAMC Salem) is seeking potential sources capable of providing/developing a Lockout procedure, placard system that complies and exceeds OSHA Standard 1910.147 utilizing Hazardous energy source icons. The contractor shall be required to have equipment surveyors who are familiar with OSHA standards as well as machinery. Hazardous energy source icons must utilize ANSI color schemes (electrical-red, pneumatic-blue, etc.). All Hazardous Energies must be identified and labeled as a primary, secondary or stored energy source. An Arc Flash identifier should be present on the Lockout Procedure (Placard) to identify the electrical hazard and for PPE awareness. Lockout Placards must be developed in Microsoft Word and all final Lockout Placard files must be supplied to the VA Medical Center in original electronic format. Energy source tags should also accompany the Lockout Placards and identify the energy sources, the magnitude, procedure for locking the equipment out and the verification procedures. The Lockout Placard should include a plan view of the equipment along with the energy icons (E1, P1, G1, etc) identifying the location of the energy sources. The placard should also include the number of locks required for zero energy. Included on the Lockout Placard should also be a location for a yearly audit check box. Simple step-by-step procedures that explain how to easily identify each energy source, locate it, disconnect it and check/verify it. This is a one-time service contractual procurement with no option years. Services shall include but not limited to locating, surveying, identifying and labeling, documenting and audit reporting of equipment. No formal solicitation document exists at this time. Responses to this sources sought notice should include the following: name and address of company; business size (large or small); identify whether or not firm falls into any of the following socioeconomic categories - 8(a), HUBZONE, Service Disabled Veteran-Owned; firm's experience in providing /developing a Lockout procedure / placard system that complies and exceeds OSHA Standard 1910.147 utilizing Hazardous energy source icons to facilities in a professional hospital, clinical or medical setting and any other pertinent information, which demonstrates your ability to meet the above requirement. All responses shall be submitted in writing no later than Noon, July 01, 2011 local time to the attention of: Delmont Friday (90C), VAMC Hampton, 100 Emancipation Drive, Bldg. 27, Hampton, VA 23667. Fax number: +1 (555) 000-0000. E-mail address: contact@example.gov. If you have questions or need additional information, please contact Delmont Friday.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS