Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Department Of Veterans Affairs was posted on April 24, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

AMSCO 705HP Washer/Disinfector

Closed
36C25526Q0350Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 339113
New
Federal
STERIS InnoWave Irrigator
Solicitation # 36C24126Q0765
The Department of Veterans Affairs, through the Network Contracting Office 01, is soliciting quotes for the procurement of one STERIS InnoWave PCF Sonic Irrigator for the Sterile Processing Services Department at the Manchester VA Medical Center in New Hampshire. This combined synopsis and solicitation is a small business set-aside under NAICS code 339113. The requirement is justified as a single-source procurement from Steris Corporation due to compatibility with existing workflows and infrastructure, though the equipment may be acquired through small business distributors. The scope of work includes the delivery, installation, and operational verification of the unit, as well as the deinstallation and disposal of the existing inoperable ultrasonic cleaner and all associated packaging materials. The contractor must provide onsite operational training for staff covering maintenance, safety, and troubleshooting. Delivery is required no later than 45 days after receipt of order, with full installation and verification completed within 90 calendar days of the award. Award decisions will be based on price, past performance, and speed of delivery. Interested offerors must submit their quotes by September 21, 2026, including their Unique Entity Identifier and a statement of agreement with the solicitation terms. All services and equipment must be delivered and accepted at the Manchester VA Medical Center.
241-NETWORK Contract Office 01 (36C241)

POSTED

1 day ago

DEADLINE

in 9 days

AI Contract Overview

Show more

The contractor is tasked with furnishing and installing four AMSCO 7053HP Washer Disinfectors, four SCS Conveyors, one SCS Return Door, four RAS Cycles, and two RAS 12 Long Racks at the Kansas City Veterans Administration Medical Center located at 4801 Linwood Blvd, Kansas City, MO 64128, to support the Sterile Processing Service across multiple clinical areas including the OR Surgical Suites, Cath Lab, Dental Clinic, Eye Clinic, and Podiatry Clinic. Installation must include uncrating, placement, assembly, plumbing for drain only, connection to a 460-480V, 3-phase, 60Hz electrical system, integration with the Censitrac Instrument Tracking System, and compliance with AAMI ST79-2017 and 2020 Amended standards for mechanical cleaning equipment. All packaging debris must be removed and properly disposed of, and comprehensive, shift-covering training for clinical staff is required, along with annual retraining. The contractor must ensure that all work is performed by fully qualified technicians, adheres to OSHA, NFPA 10, and VA Design Guide standards, and includes the provision and monthly maintenance of portable fire extinguishers in accordance with NFPA 10, 2018 edition. Post-installation, the vendor is obligated to provide full-service maintenance through a service agreement with strict response timelines: emergency failures causing total or partial equipment outages must be addressed within four hours, with a temporary solution implemented within 24 hours and a permanent resolution planned and ordered within five days. The installation and all maintenance activities must occur during standard business hours of 7:30 a.m. to 4:00 p.m., Monday through Friday, unless otherwise directed by the Contracting Officer Representative. All documentation, including service reports in both hardcopy and electronic formats, must be submitted to the Biomedical Engineering department. The contract is a Firm Fixed Price, with delivery and acceptance occurring FOB Destination at the Kansas City facility, and performance is subject to monitoring by the Contracting Officer, Contracting Officer Representative, Infection Control Risk Assessment Office, and Safety Office. Offerors must be registered in SAM.gov, provide an Authorized Distributor Letter from the OEM, and submit a two-part proposal—separate priced and non-priced submissions—with the non-priced component including technical capability statements and no more than three past performance references.

General Info

Furnish, install, maintain AMSCO washer disinfectors and conveyors with training and compliance at Kansas City VA.

Agency

Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)View Agency

Contract Value

$846,504.23

NAICS

339113 - Surgical Appliance and Supplies ManufacturingView NAICS

Place of Performance

Kansas City, MO, 64128, USA

Set-Aside

NONE

Awardee

BEACON POINT ASSOCIATES LLCView Profile

Award Issued Date

Documents

(1)

Solicitation 36C25526Q0350 for AMSCO 7053HP Washer Disinfectors

PDFrfq

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Organization / Agency
Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
View Agency Profile
Office AddressLEAVENWORTH, KS, 66048, USA

Full Description

Show more

Statement of Requirement


This scope of work outlines the contractor’s responsibility to furnish all labor, travel, transportation, materials, shipping, parts, connections, and equipment required for the provision and on-site installation of the following at 4801 Linwood Blvd, Kansas City, MO. 64128, to support the Sterile Processing Service (SPS) department for medical procedures and surgeries in the OR Surgical Suites, Cath Lab, Dental Clinic, Eye Clinic, and Podiatry Clinic: four (4) AMSCO™ 7053HP Washer Disinfectors, four (4) SCS Conveyors, one (1) SCS Return Door, four RAS Cycles for 7053HP, and two (2) RAS 12 Long Racks.



The contractor will also provide comprehensive training to clinical staff before the equipment is used. This training must cover all work shifts within the sterile processing department, and the contractor will be responsible for annual retraining on all equipment. Additionally, the contractor shall remove and properly dispose of all debris and packing materials generated during washer equipment installation.  



The complete acquisition, procurement, and installation process includes all essential non-union labor and materials for the uncrating, setting in place, and assembly of the Steris equipment. The quoted price assumes work is performed during normal business hours, Monday to Friday, from 8:00AM to 5:00PM, unless otherwise indicated, as part of its Installation Services, Steris will also provide an operational check-out test, make any necessary adjustments and conduct a demonstration of the equipment’s functionality for the appropriate facility staff.



2. SPECIFICATIONS


    • Minimum of four washer disinfectors shall have minimum operations dimensions of 1067 x 2051 x 965 mm (42 x 80-3/4 x 38") with chamber dimensions 673 x 667 x 800 mm (26-1/2 x 26-1/4 x 31-1/2").
    • Conveyor Return Line 521lbs, (H)x31 inches (W)x32 inches (D)x161 inches
    • Plumbing-Drain only
    • Electrical: Special electrical requirements
    • Utility: Med Gas-Air, high pressure (85 PSIG) max
    • Utility: Misc-CAT 6 to nearest T-Comm Room
    • Emergency stop/disconnect capabilities
    • Pressure release push button
    • Stand-alone return line
    • Return line provides the transportation of racks to the soiled side from the clean side.
    • Prior to use all packaging material must be properly removed from the RAS Rack: two additional port connectors are safely put aside; and the RAS filter assembly is in place.
    • Ensure robotic cycle has been configured on Washer/Disinfectors.
    • Per AAMI Standards ST79-2017 & 2020 Amended A1, A2, A3, A4 (Consolidated Text) Comprehensive guide:
  • Selection of mechanical cleaning equipment should be based on the requirements for cleaning of the devices to be processed. The mechanical cleaning equipment currently available for reprocessing medical devices that are moisture-, detergent-, and temperature-stable include the following:

a) Ultrasonic cleaning equipment


b) Irrigator cleaners


c) Ultrasonic irrigators


d) Ultrasonic irrigator washers


e) Ultrasonic irrigator washer–disinfectors


f) Floor-mounted cart washer–disinfectors


g) Single-chamber washer–disinfectors


h) Multi-chamber washer–disinfectors


I) Medical washer



    • AMSCO ™ 7053HP Washer Disinfectors utility requirements:
  • Supports steam heated cycles
  • Utilizes 460-480 voltage
  • 3Ph, 60Hz electrical system
    • Shall provide Robotic Assisted Surgery Instrument thermal disinfection cycle capabilities.
    • Shall provide Auto docking transfer cart for Long Chamber Washer/Disinfector for

                transferring accessories into and out of the washer/disinfector. Includes Bottle collection kit.


    • Shall integrate with the Censitrac Instrument Tracking System.



3. REQUIREMENTS


  • The contractor is responsible for conducting site visits to verify existing conditions, material quantities, installation instructions, and identify any discrepancies or conflicting requirements in the Statement of Work before submitting the Final Proposal.
  • The contractor shall provide and install four (4) 7053HP Washer Disinfectors with four (4) SCS Conveyors and RAS capabilities to the VA Medical Center located at 4801 Linwood Kansas City, Mo 64128. 
  • The contractor shall ensure that all repairs, preventable, and remedial maintenance provided during the provision timeframe of this contract meet and or exceed the OEM’s specifications.
  •  The contractor shall ensure that only FULLY QUALIFIED TECHNICIANS/ENGINEERS are employed in the performance of all work performed under this contract.
  • The contractor must maintain the highest standard of professional capability and workmanship is maintained throughout the life of this contract.


4. EQUIPMENT MAINTENANCE & RESPONSE TIMES



The vendor shall provide full-service maintenance through a service agreement post installation. The vendor shall provide all additional recurring and preventative maintenance activities:



  1. Emergency response for equipment and MSPS failures. For any equipment failure causing a total or partial loss of the equipment, the vendor must respond to the facility within 4 hours of VMAC contact. If a permanent solution cannot be implemented within 24 hours of the initial failure, a temporary solution must be operational within that same 24- hour period. A permanent solution, including any necessary replacements, shall be planned and ordered within 5 days of the initial failure. 


5. SAFETY



The contractor/vendor shall always, ensure that all work provided complies with all local, State, and Federal rules and regulations pertaining to workplace safety. The contractor shall take all proper safety and health precautions to protect the work, the workers, the public and the property (OSHA). Installs and construction work will be in accordance with all applicable codes to include the most current codes National Fire Protection Association (NFPA), and the VA Design Guide Manuals that are applicable to the work. If the design guide is equivalent or more stringent then the mentioned codes, the VA Design Guide takes precedence.



FIRE EXTINGUISHERS: Portable fire extinguishers shall be provided, hung, inspected, and maintained monthly by the Contractor in accordance with NFPA 10, 2018 edition.




6. DOCUMENTATION



The contractor shall furnish to the KCVA Medical Center Biomedical Engineering department legible hard copies and electronic copies of service reports of the maintenance indicating details of the maintenance performed upon completion of all work.



7. PLACE OF PERFORMANCE



Kansas City Veteran Administration Medical Center, 4801 Linwood Blvd. Kansas City 64128



8. PERFORMANCE MONITORING



The contractor’s performance will be monitored by the Contracting Officer (CO), Contracting Officer Representative (COR), Infection Control Risk Assessment Office, and Safety Office during the rental agreement period.



Coordinate all administrative and construction requirements exclusively with or through assigned Contracting Officer Representative (COR).



The Construction Safety Officer, Construction Safety Committee, and COR will review the operations and site construction conditions of the project to confirm that all Safety regulations relating to construction and healthcare facilities are being adhered to. Daily and weekly safety rounds will be conducted. For non-compliance safety related issues, a safety report will be sent to the Contractor to correct within 14 days. Non-compliance may result in job-site suspense until compliance is met at the contractor’s expense.



9. HOURS OF OPERATION



The contractor will perform services required during the hours of 7:30 am – 4:00 pm, Monday through Friday or as directed by the designated COR.

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 333310
New
Federal
Supply and Install Pot, Pan and Utensil Washer for KC VAMC (brand name or equal to Hobart PW20)
Solicitation # 36C25526Q0656
The Department of Veterans Affairs, through the Heartland Network 15 Contracting Office, is conducting market research via a Sources Sought Notice to identify qualified small businesses, including SDVOSBs, VOSBs, 8(a), and HUBZone firms, for the procurement of a commercial pot, pan, and utensil washer. The requirement is for a new OEM commercial flight-type dishwasher, specifically a Hobart PW20 or an approved equal, to be installed at the Kansas City VA Medical Center in Missouri. The anticipated scope of work includes the removal and disposal of existing equipment, delivery, installation, commissioning, and the provision of on-site operator training. The equipment must meet strict physical dimensions, NSF sanitation standards, and UL/cUL safety listings, with a required minimum one-year parts and labor warranty. The project requires the contractor to complete delivery and installation within 60 calendar days of the order, with a target need-by date of November 15, 2026. Technical performance criteria include specific sanitization temperatures, water usage limits, and functional throughput capacities. Contractors must provide proof of authorized reseller status to prevent the use of gray-market items and must comply with VA security, privacy, and safety protocols, including PIV badging and infection control risk assessments. Interested parties must submit their capabilities statements and relevant OEM authorizations to the designated point of contact by September 15, 2026. The government may use this information to determine if the final procurement will be set aside for specific small business categories under NAICS code 333310.
Commercial and Service Industry Machinery Manufacturing

POSTED

1 day ago

DEADLINE

in 3 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS