ANALYZER, GAS FLOW
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The gas flow analyzer is a sophisticated medical device designed to measure bidirectional air flow, high and differential low pressure, barometric pressure, oxygen concentration, airway pressure, airway temperature, and airway humidity, with specialized capabilities for testing mechanical patient ventilators. It supports external control via USB commands and can be fully automated using compatible software, enabling precise and efficient operation in clinical or testing environments. The unit is powered by a rechargeable lithium-ion battery or an external power supply, allowing for both portable and stationary use. The VT900A MIL KIT includes the gas flow analyzer, a portable test lung, vapor and Pelican case for durable transport and storage. The item is identified by NSN 6515-01-696-5253 and is sold as a single unit, with a requested delivery within 20 days of award. The solicitation is issued under contract SPE2DS-26-T-278U as a Total Small Business Set-Aside, with responses due by August 3, 2026. Technical and quality requirements referenced by R or I numbers are governed by the DLA Master List of Technical and Quality Requirements, with the applicable revision determined by the solicitation or award date. Packaging must comply with DLA standards, and all non-accepted supplies must have government identification removed prior to return. Bidders are required to specify the exact source and part number being offered. The contract is managed by the Department of Defense’s Medical Supply Chain under the Office of MEDICAL SUPPLY CHAIN MD SURG FSF, with Vernon Stevenson listed as the primary point of contact for inquiries.
General Info
Agency
NAICS
Place of Performance
UNIT 2497 CP 011 496 371 46 2418, APO, AE, 09094-3219, USSet-Aside
Documents
(1)AI Contract Breakdown
Uniform Contract FormatWhat is UCF?
Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.
Timeline
Response Deadline
Organization & Contact Information
Full Description
ANALYZER, GAS FLOW.
ITEM MEASURES BI-DIRECTIONAL AIR FLOW, HIGH AND DIFFERENTIAL LOW
PRESSURE, BAROMETRIC PRESSURE, OXYGEN CONCENTRATION AND AIRWAY PRESSURE,
AIRWAY TEMPERATURE AND AIRWAY HUMIDITY; SPECIAL FEATURES FOR TESTING
MECHANICAL PATIENT VENTILATORS ; THE ANALYZER CAN BE CONTROLED
EXTERNALLY USING USB COMMANDS OR AUTOMATED WITH AVAILABLE SOFTWARE;
OPERATES ON A RECHARGEABLE LI-ION BATTERY OR EXTERNAL POWER SUPPLY FOR
STATIONARY OR PORTABLE USE; VT900A MIL KIT CONTAINS: GAS FLOW ANALYZER,
PORTABLE TEST LUNG, VAPOR AND PELICAN CASE.
UNIT OF ISSUE: EACH (EA)
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS
(IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE
DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB
AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
BIDDER: SHALL SPECIFY SOURCE AND PART
NUMBER BEING SUPPLIED.
ADEQUATE DATA FOR THE NSN/Part Number: 6515-01-696-5253 Quantity: 1 EA Purchase Request: 7017644301QTY: 1 Delivery: 20 days ADO