Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Agriculture was posted on August 19, 2013. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Annual maintenance and emergency repairs for 9 generators at Moore Air Base TX

Closed
AG-6395-S-13-0075Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation (MTC) is soliciting bids for the clutch replacement of a Kubota M8200 tractor with front wheel assist, no cab or loader, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires the contractor to provide all transportation, labor, supervision, tools, and new manufacturer-specified parts to diagnose and repair the clutch assembly and power take-off (PTO) system. Key technical requirements include disassembling tractor components, replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as necessary. The project is complete once the Facility Maintenance Department verifies proper clutch engagement and PTO operation under load. This is a small business set-aside opportunity under NAICS code 811310, open to various SBA-certified categories including VOSB, SDVOSB, WOSB, and HUBZone businesses. Proposals must be submitted via email to Angie Mahoney by November 3, 2026, and must include a lump sum bid sheet, a completed supplier packet with a W-9 and self-certification form, and proof of insurance. Award will be based on best value, considering the contractor's qualifications, experience, and the itemized cost breakdown. The contract is subject to Federal Acquisition Regulation (FAR) clauses regarding the Buy American Act, combating trafficking in persons, and Service Contract Labor Standards per Wage Determination No. 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 2 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
**Certified SB/DVBE Only** IFPQ Boiler Inspection, Maintenance, Repair, Testing, and Reporting in Los Angeles County
Solicitation # 07A6539
The California Department of Transportation (Caltrans) is soliciting price quotes for an Invitation for Price Quote (IFPQ 07A6539) to provide comprehensive boiler inspection, maintenance, repair, testing, and reporting services at the District 7 Office facility in Los Angeles, California. The scope of work includes annual and quarterly preventative maintenance for three Unilux water tube boilers and six boiler pumps, ensuring compliance with manufacturer standards, ASME Code, OSHA requirements, and South Coast Air Quality Management District standards. This is a set-aside solicitation exclusively for certified Small Business (SB), Microbusiness (MB), or Disabled Veteran Business Enterprise (DVBE) entities. The contract will be awarded to the responsible bidder offering the lowest price quote who meets all specifications. Key operational requirements include a 48-hour response time for routine service requests and a strict prohibition on subcontracting any portion of the work. The contractor must adhere to State General Prevailing Wage Rates for Los Angeles County and provide a payment bond for any service request exceeding 25,000 dollars. Required submission documents include a Price Quote Proposal, Bidder Certification Sheet, Non-Collusion Declaration, and certifications for California Civil Rights Laws and the Darfur Contracting Act. Invoicing is conducted monthly in arrears and must be accompanied by certified payroll records and DVBE utilization reports. The agreement is subject to a budget contingency clause, meaning it is enforceable only if sufficient funds are provided by the California State Legislature or the United States Government.
California Department of Transportation

POSTED

about 11 hours ago

DEADLINE

in 15 days
NAICS: 811310
New
SLED
Dietary Equipment Service Agreement
Solicitation # BPM059212
Clifton T. Perkins Hospital Center is soliciting bids for a Dietary Equipment Service Agreement to provide inspections and maintenance for industrial food and beverage equipment within the facility's main kitchens. This Small Business Reserve Procurement is limited to vendors certified by the Governor's Office of Small, Minority and Women Business Affairs. The scope of work includes regular inspections for wear and tear, preventive maintenance, and specific calibration for refrigeration, freezers, cooking appliances, sanitation and warewashing equipment, ventilation, and ice machines. The contract is an Indefinite Quantity agreement with Fixed Unit Prices, featuring a one-year base period and a total award cap of 50,000 dollars. Qualified bidders must hold a Maryland HVACR license issued by the Department of Labor and provide three professional references demonstrating at least three years of relevant experience. Because the facility is a secure psychiatric hospital, contractors must adhere to strict safety and conduct guidelines, including tool inventory controls, patient confidentiality agreements, and professional dress codes. Site visits must be requested by email to the Procurement Officer by October 20, 2026. Bids must be submitted exclusively via the eMMA portal by November 4, 2026, at 2:00 pm. Award will be granted to the responsible bidder offering the most favorable bid price.
Clifton T. Perkins Hospital Center

POSTED

about 13 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 16 hours ago

DEADLINE

in about 2 months

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

USDA APHIS PPQ RMS Bldg 6407, Moore Air Base 22675 N Moorefield Road, EDINBURG, TX, 78541, USA

Set-Aside

NONE

Documents

1

FBO_Sources_Sought_--_final.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Response Deadline

Deadline has passed

Posted

Sources Sought

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Agriculture → Mrpbs Minneapolis Mn
Contacts1 person available
OfficeMINNEAPOLIS, MN, 55401, USA
Office AddressMINNEAPOLIS, MN, 55401, USA
Contacts

Full Description

Show more
See attachment also. DESCRIPTION OF SERVICE REQUIREMENT: The United States Department of Agriculture (USDA) Animal Plant Health Inspection Services (APHIS) Plant Protection and Quarantine (PPQ), Field Maintenance Services (FMS), Moore Air Base, Mission, TX seeks services for annual generator maintenance and emergency repairs for a 5 year contact. Provide maintenance to all makes and models of generator sets in accordance with the National Electric Code (NEC), the Life Safety Code, the National Fire Protection Association, and the Joint Commission. Provide the following services: 1. Annual Inspection maintenance, Preventive Maintenance, Testing and other services; 2. Unscheduled maintenance or Emergency Repair; 3. Miscellaneous parts not covered under Annual Service List of generator types. Make Model Serial # kW Cust Unit ID Cat SR4 5LA0327 500 Bldg# 6414 Kohler 500RE0ZVB 2057786 500 Bldg# 6418 Cummins DFEG7254973 J080214252 350 Bldg# 6403 Cummins DGFC3388088 B000062603 200 Cattle Tick Cummins GGHH5629777 H030537392 100 Bldg# 6417 Cummins DGDK5599205 B030469729 125 By T10 Generac 90A04172-S 994534 175 Recycle Area Kohler 100R0ZJ81 355596 100 Bldg# 6412 Kohler 40R0ZJ81 281133 40 Guard Shack All findings shall be recorded throughout the inspections and a written report submitted for each generator prior to leaving the installation. INSPECTION GENERAL - Visual Inspection - Visual inspection of overall condition of unit to identify foreign objects, loose or broken fittings, guards, and components. - Wipe off unit - Clean oil, coolant, fuel and acid deposits. Police generator area. COOLING SYSTEM - Radiator/Heat Exchanger - Visual inspection for leaks, damage, and debris. Louvers operate correctly. - Coolant - Visual inspection for correct level and condition of coolant (rust, oil, and contaminants). Check coolant conditioner concentration and temperature protection. Check filler cap gasket and sealing surface. - Hoses and Connections - Visual inspection of all hoses for deterioration. Check tightness of connections. - Fan Drive Pulley and Fan - Check for loose or worn pulleys and lube fan drive bearing. Check fan operation and clearance. - Fan Belts - Inspect for wear or deterioration. Check tension and adjust as necessary - Jacket Water Heater - Inspect for proper operation. Check thermostat settings for proper coolant temperature. - Water Pump - Visual and operational inspection for leaks or unusual noises. FUEL SYSTEM - Fuel Tank - Visually inspect fuel tank system for leaks and fuel level. Test day tank pump for proper operation. Inspect fuel condition for contaminants (Color Kut). - Water Trap/Separator - Drain water from fuel tank or water separator when possible. - Fuel Lines and Connections - Inspect for leaks and tightness of connections. Check line brackets. - Governor and Controls - Inspect governor oil level. Inspect controls and linkage for proper operation. Add oil as necessary. - Fuel Filters (Primary/Secondary) - Inspect for damage, leaks and proper operation. - Fuel Pressure - Operational check of gauge and correct pressure. AIR INDUCTION AND EXHAUST SYSTEM - Air Filter Service Indicator - Note reading. Inspect for proper operation. Reset indicator. - Air Filter - Inspect. Clean as necessary. - Air Inlet System - Inspect piping and air filter housing for damage, loose connections, and evidence of leaks. Clean air filter housing if air filter is cleaned or replaced. Check housing seals and gaskets. - Turbocharger - Inspect for oil leakage or exhaust leakage. Check for unusual noises and proper operation. - Exhaust Manifold - Inspect for damage, loose or missing hardware, evidence of exhaust leakage. Inspect for oil slobbering. Load bank recommendation. - Exhaust System - Inspect silencer and piping for damage, corrosion, or leakage. Check rain cap. Check supports for vibration damage and loose connections. LUBE OIL SYSTEM - Oil Level - Inspect for correct oil level and contamination. Visually inspect unit for leaks. - Oil Pressure - Operational check of gauge for correct pressure. Operational and visual inspection of prelube pump. - Crankcase Breather - Inspect for proper operation. Check connections and inspect hose for deterioration. Note excessive blowby. - Scheduled Oil Sample - Obtain oil sample for analysis. STARTING SYSTEM - Batteries - Inspect for damage or leakage, clean battery acid neutralizer. Clean and tighten all battery cable connections. - Batteries (Specific Gravity) - Check electrolyte level and specific gravity. - Battery Charger - Inspect for proper operation, loose terminals, and deteriorated wiring. - Starting Motor - Inspect electrical connections and wiring. For air starters, inspect oil jar and feeder operation. Operational check for abnormal engagement and cranking noises. - Alternator - Inspect for proper operation, loose connections, and mounting hardware. Check belts, pulley and voltage output. ENGINE MONITORS AND SAFETY CONTROLS - Safety Controls - Check for: loose connections, and wiring deterioration. - Remote Annunciator and Alarms - Inspect all panel and system alarms. CONTROL PANEL - Start Controls-Manual/Auto - Operational check for proper operation. Check automatic start (if allowed). - Voltmeter - Operational check for correct readings. Check voltage level, voltage gain, and voltage drop adjustment. - Ammeter - Operational check for correct readings, if load is available. - Frequency Meter - Operational check for correct readings. Load and no load readings, if possible. MAINTENANCE FUEL SYSTEM - Fuel Filter - Replace. Inspect for proper sealing and operation. LUBE OIL SYSTEM - Oil and Filters - Change. Inspect all gaskets and seals. - S.O.S. - Obtain oil sample for analysis. - Crankcase Breather - Inspect and clean. AIR INDUCTION SYSTEM - Turbocharger - Inspect turbocharger for proper rotating assembly. Check for oil leakage or unusual noises. - Air Filter - Inspect. Clean or replace as necessary. ENGINE MONITORS AND SAFETY CONTROLS - Gauge Accuracy - Check oil pressure, water temperature, and alternator gauges for accuracy - Safety Controls - Inspect for proper operation, loose connections, and wiring deterioration. Check all safety controls for proper operation. - Remote Annunciator and Alarms - Inspect and test all panel and system alarms for proper operation. - Sending Unit Switches - Check water temperature and oil pressure. GENERATOR - Generator Rear Bearing - Lubricate - Vibration Isolators - Check for proper adjustment and condition. CONTROL PANEL - Circuit Breakers - Inspect for free movement and tight connections. OTHER SERVICES TRANSFER SWITCH PREVENTIVE MAINTENANCE INTERIOR WIRING COMPONENTS - Perform visual inspection of all wiring and connections for signs of tracking, overheating, and insulation deterioration - Check and tighten, where necessary, all control circuit wiring terminals. - Check manual switches for free movement and contact continuity. - Check all time delay settings and adjust to the customer's specifications. - Check condition of main and arcing contacts and auxiliary contacts. - Check all common and ground wires. Measure and record resistance to ground readings. - Check lug connections and mounting insulator bolts (de-energized switch). - Megger test for grounds or leakage. - Check for proper transfer operation and sequencing of time control relays. - Calibrate all phase and voltage sensitive relays. - Perform relative infrared heat scan on all contacts. ENCLOSURE - Wipe down. - Clean interior of enclosure and remove accumulated dust and/or dirt. - Check door closure, locking bar, and mechanism for proper operation. LOAD BANK TESTING - - Conduct Load Bank Test on all generators for a minimum of two continuous hours at 80-100% of the nameplate rating to be performed in conjunction with annual preventive maintenance services. The date and time of day for testing shall be decided by the Government based on facility operations. MEGOHMMETER TESTING - Test main stator, main rotor, exciter stator, and exciter rotor. Record data for reference. FUEL ANALYSIS - Fuel analysis will include, but is not limited to testing for the following in accordance with ASTM D 975 Requirements for Diesel Fuel Property Test Method(*) Low Sulfur No. 1-D No. 1-D Low Sulfur No. 2-D No. 2-D No. 4-D Flash Point, - C, min D 93 38 38 52 52 55 Water and Sediment, % vol, max D 2709 0.05 0.05 0.05 0.05 D 1796 0.05 Distillation temperature, - C D 86 90% vol recovered Min 282 Max 288 288 338 Kinematic viscosity, 40 C sCt D 445 Min 1.3 1.3 1.9 1.9 5.5 Max 2.4 2.4 4.1 4.1 24 Ash, % mass, max D 482 0.01 0.01 0.01 0.01 0.1 Sulfur, % mass, max D 2622 0.05 0.05 0.05 0.05 2 Copper strip corrosion, 3 hr at D 130 No. 3 No. 3 No. 3 No. 3 50 C, max rating Cetane number, min D 613 40 40 40 40 30 One of the following: 1) Cetain index, min D 976 40 40 2) Aromaticity, % vol, max D 1319 35 35 Ramsbottom carbon residue D 524 0.15 0.15 0.35 0.35 on 10% distillation residue, % mass, max MISCELLANEOUS - Record findings of the inspection. - Note corrective action taken. - Report unsafe conditions. - Report recommendations for replacement of major components. - OTHER MAINTENANCE AS REQUESTED Interested manufactures should send a statement of capabilities, your DUNS and TIN numbers via email to Leigh Eberhart at contact@example.gov

More opportunities from Department Of Agriculture → Mrpbs Minneapolis Mn

Same awarding agency

NAICS: 561720
New
Federal
JANITORIAL SERVICE - Kentucky Area
Solicitation # 12639527Q0005
Solicitation 12639527Q0005 is a request for janitorial services for the USDA Animal and Plant Health Inspection Service (APHIS) Kentucky Area Office and Regional Laboratory, located at 105 Corporate Drive, Frankfort, KY. The contract is a total small business set-aside under NAICS code 561720. The selected contractor will provide all personnel, equipment, and tools to maintain 9,500 square feet of facility space. Services are to be performed Monday through Friday from 7:30 a.m. to 4:30 p.m., with specific requirements including quarterly mopping and waxing of the working laboratory section. The award is structured as a firm-fixed price requirements contract consisting of a one-year base period and four one-year option periods, with a total duration not to exceed five years. The government will award the contract based on best value, selecting the highest technically rated offeror provided the price is fair and reasonable and past performance is acceptable or neutral. Technical evaluation focuses on the offeror's ability to meet the Statement of Work schedule and their understanding of the requirements. Compliance mandates include adherence to OSHA safety standards for hazardous substances, Green Cleaning legislation for consumables, and Service Contract Labor Standards. The Contracting Officer or a designated representative will be responsible for inspection and acceptance of the services. Offerors must submit a technical approach, detailed pricing for all line items, and past performance references to be considered responsive.
Janitorial Services

POSTED

about 20 hours ago

DEADLINE

in 10 days
View Details
NAICS: 325414
New
Federal
Foot and Mouth Disease (FMD) Vaccine Antigen Concentrate (VAC)
Solicitation # 12639527R0001
Solicitation 12639527R0001 is a request for proposal issued by the USDA Animal and Plant Health Inspection Service (APHIS) for an unrestricted, IDIQ contract focused on Foot and Mouth Disease (FMD) Vaccine Antigen Concentrate (VAC). The scope of work includes the purchase and storage of VAC, the conversion of Government-owned VAC into usable finished vaccines, and the direct purchase of finished vaccines. The contract features a ceiling price of 800 million dollars and a long-term performance horizon, consisting of five one-year ordering periods for VAC and direct purchases starting December 1, 2026, with conversion and delivery of finished vaccines extending through November 30, 2044. The contractor is required to produce VAC with a minimum capacity of 1.0 million doses and maintain storage on their premises under strict quality control and temperature monitoring standards. Due to the nature of the material, live FMDV is classified as a Tier 1 Select Agent, requiring specific authorization from the CDC/APHIS and adherence to rigorous shipping and security restrictions. Award will be based on the most advantageous offer, evaluating technical capability, past performance, and price, with technical and past performance factors weighted equally. Proposals must be submitted electronically in four separate volumes by November 10, 2026.
Biological Product (except Diagnostic) Manufacturing

POSTED

3 days ago

DEADLINE

in 12 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS