This Sources Sought opportunity from Department Of Defense was posted on March 6, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
B1130 ROOF REPLACEMENT
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
General Info
Place of Performance
Sumter, SC, 29151, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
1. Description:
This is a Sources Sought Notice and is issued solely for market research and planning purposes to identify potential sources capable of providing the construction needs for a Design-Build (DB) contract to execute a complete roof replacement for Section A of Building 1130 (highlighted in the Condition Assessment Report) at Shaw AFB.
The contractor shall provide all design, engineering, labor, materials, equipment, and supervision necessary to:
a) Completely demolish the existing roofing system down to the structural concrete deck to include the elevator shaft roof.
b) Repair the spalls and cracks on the existing concrete deck. Prepare the concrete deck with a new air & vapor barrier and insulation board for a standing seam metal roofing retro fit/hugger system.
c) Design and install a new, fully compliant, Single Sloped Hydrostatic Standing Seam Metal Roofing hugger system incorporating an adequate slope to ensure positive water drainage/flow. The slope of the new SSMR will be directed to the back of the building. The height of the new SSMR must not be higher than the existing front building’s parapet wall height primarily to maintain the overall aesthetic of the building’s front. Demolish all parapet wall in the rear building area to incorporate a new external drainage system at the rear of the building. All existing drainage and appurtenances of the building is to be sealed and removed.
d) Design and install a new, 2-ply, cold-applied SBS Modified Bitumen roofing system, complete with new insulation for the elevator shaft. The system shall be drained via new scuppers designed to discharge water onto the new main standing seam metal roof.
e) Engineer and execute a comprehensive redesign of the drainage system, demolishing the 25 existing internal drains, in its entirety. The new external drainage system will be located at the back of the building. The sizing of the gutters, downspouts and tie-in locations to the storm drains must be designed to handle the massive volume and velocity of water from a 100-year storm event impacting the entirety of the new roof.
f) Demolish the existing penthouse roof access. Demolish all existing access past the floor below the roof as these appurtenances are no longer required. Provide all necessary renovations and additions to structurally frame and fill the opening left from the penthouse demolition. Provide all necessary renovations and additions to retain stairway functions, fire rating and overall operations after transformation (drop down ceiling, lights, fire protection system etc).
g) Remove and replace all metal coping on all the remaining parapet walls, including the elevator shaft.
h) Extend existing vents, roof curbs, ducts and other penetrations as required and flash properly.
i) Install a new Horizontal Lifeline System / Fall Protection System.
j) Ensure all work complies with the Unified Facilities Criteria (UFC), UFC 3-110-03 Roofing, the Shaw AFB Design and Construction Guide, and all attached specifications.
k) Accomplish the work while omitting/minimizing operational impact on the fully functional, 24/7 mission-critical B1130 facility.
2. Submission Requirements:
Interested vendors are invited to submit the following information:
Company Information
- Company name, address, and point of contact (name, email, phone)
- CAGE code and UEI (if available)
- Applicable NAICS codes
- Capabilities Statement
- Description of your ability to fulfill the listed requirements in the Statement of Work
- Indicate your ability to perform at Shaw, AFB.
3. Submission Instructions:
Response Deadline: 13 March 2026, 4:00 PM EST
Submission Method: Email responses to hutton.cobb@us.af.mil
Subject Line: Sources Sought Response - B1130 Roof Replacement.
Disclaimer: This Sources Sought is issued solely for information and planning purposes and does not constitute a solicitation. This notice shall not be construed as a commitment by the Government to issue a solicitation or award a contract. The Government will not reimburse any costs incurred.
More opportunities from Department Of Defense → FA4803 20 Cons Lgca
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS
