The contract is for the application of a seamless, 80-mil, two-component aluminized polyurea spray-on roofing system over the existing roofs of Buildings 6030A and 6030C at Dyess Air Force Base, Texas, covering approximately 26,060 square feet. The work must extend fully to the roof edge and achieve a color match as close as possible to dark bronze, strictly adhering to the manufacturer’s specifications, the Statement of Work, and Attachment C, which details the aluminized polyurea roof coating system. The project requires extensive surface preparation including power washing, scraping, and scrubbing, with all Lightning Protection System components masked to prevent contamination. The final coating must meet strict performance standards including 85 ± 5 Shore A hardness, 225% ± 50% elongation, 2000 ± 200 PSI tensile strength, 250 ± PLI tear resistance, and permeability greater than 0.02 perm inch, all tested per ASTM standards. The contractor must arrange for a manufacturer’s inspection prior to warranty issuance and obtain third-party recertification of the Lightning Protection System in compliance with UFCs 3-110-03 and 3-575-01, with all test points tagged to the as-built roof plan. Any failed LPS components must be repaired at no additional cost to the government until certified. The contract is a total small business set-aside under NAICS code 238160, with evaluation based solely on lowest price technically acceptable. The period of performance is 120 calendar days from the Notice to Proceed, and all materials must arrive in manufacturer’s original unopened containers with full labeling including manufacturer, formula, lot number, color, date of manufacture, mixing instructions, shelf life, and curing time. Materials must be stored above 60°F, on wooden pallets, with drums rotated regularly and fitted with desiccants during use. MSDS must be on-site at all times. The contractor must provide temporary restrooms and power generation if needed, obtain approval for the lay-down area, and dispose of all debris off-base compliant with federal, state, and local regulations. Site access requires prior coordination for base entry, with a mandatory site visit on July 20, 2026, and a proposal submission deadline of August 6, 2026. Amendments have
General Info
Agency
NAICS
Place of Performance
Dyess AFB, TX, 79607, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
Amendment 2
1. Add 6030 A Partial As-Builts as an attachment.
2. Add 6030 C Partial As-Builts as an attachment.
3. Add As-Builts 6030A-1984 as an attachment.
4. Add As-Builts 6030C-1988 as an attachment.
5. Add Dyess Roof Sealant QA Log as an attachment.
6. All other terms and conditions remain unchanged.
1. Amendment 1
1. Extend proposal due date to August 6, 2026.
2. All other terms and conditions remain unchanged.
Project Title: B6030 A/C Roof Sealant
Project Location: Dyess AFB, B6030
Project Description: Apply a seamless, 80-mil, two-component aluminized polyurea spray-on roofing system over the existing roof, extending the coating fully to the roof edge. Perform all installation in strict accordance with the manufacturer's specifications, the attached Statement of Work, and Attachment C. The final polyurea coating must achieve the closest possible color match to dark bronze.
Project Magnitude: The disclosure of the magnitude for this requirement is between $250,000,000 and $500,000,000
Project Length: Period of Performance: 120 calendar days from Notice to Proceed.
Site Visit: The Site Visit will be held on 20 July 2026 at 10:00 AM CST. The building is located at B6030, 617 Ave C., Dyess AFB, TX 79607. All interested vendors that would like to participate in the site visit and require base access must email the contract specialist TSgt Marshal Khinno at marshal.khinno@us.af.mil and the contracting officer Ms. Traci Hughes at traci.hughes.1@us.af.mil no later than 16 July 2026, 9:00 AM CST.
*NOTICE: This is a combined Site Visit with the Solicitation Notice FA466126R0007 (B6030 A/C Roof Repair).*
Questions and Answers: Questions are due to TSgt Marshal Khinno at marshal.khinno@us.af.mil and Ms. Traci Hughes at traci.hughes.1@us.af.mil on 22 July 2026 at 2:00 PM CST.
Proposal Due Date: Proposals are due 6 August 2026 at 4:00 PM CST.
Evaluation of Offers: The evaluation for this acquisition will be solely based on the lowest price found technically acceptable.
More opportunities from Department Of Defense → FA4661 7 Cons Cd
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 650+ contractors already using CLEATUS