Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Department Of Defense was posted on April 27, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

BATTERY, VENTILATOR

Closed
SPE2DS-26-T-016AFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 339112
New
Federal
SPS Sterilizer
Solicitation # 36C24526Q0758
Solicitation 36C24526Q0758 is a Firm-Fixed Price purchase order issued by the Department of Veterans Affairs for the procurement, delivery, and installation of five new steam sterilizers for the Sterile Processing Service at the Baltimore VA Medical Center in Maryland. The government is seeking Belimed brand or equal equipment with specific requirements, including a chamber volume of at least 275 L and a tray capacity of at least five trays. The project involves a two-phase installation process to maintain continuous operations, requiring the contractor to handle the de-installation and disposal of existing equipment, site preparation, utility reconnection, and the provision of ICRA plans and barriers. System validation and assembly must be performed by an OEM service-trained representative. The award will be based on a comparative evaluation of technical capability, price, and past performance to determine the most advantageous offer to the government. Mandatory submission requirements include a completed SF1449, a specific line-item pricing worksheet, and manufacturer authorization letters for distributors. All quotes must be submitted as FOB Destination. The contractor is required to maintain specific insurance coverages, including 500,000 dollars per occurrence for general liability and 200,000 dollars per person for automobile liability. The response deadline for this unrestricted solicitation is September 14, 2024.
245-NETWORK Contract Office 5 (36C245)

POSTED

1 day ago

DEADLINE

in 2 days

AI Contract Overview

Show more

The contract specifies the procurement of two ventilator batteries with part number MSP369108, manufactured by Hamilton Medical, Inc., under solicitation SPE2DS-26-T-016A, with a delivery requirement of 20 days to Goose Creek, South Carolina. Each unit must be packaged in sealed commercial containers designed to prevent damage during transit, and all shipments must use commercial exterior containers ensuring safe, low-cost delivery via common carrier. All items must conform to the Medical Marking Standard No. 1, which supersedes MIL-STD-129, and must be marked accordingly with traceable labeling. The product is classified as a FDA-regulated Class II medical device and requires compliance with registration, listing, labeling, and GMP standards, though a 510(k) submission is not mandated. A 36-month non-extendable shelf life applies, and the batteries must be shipped by traceable means only—parcel post is prohibited. The delivery is FOB destination, with inspection and acceptance occurring at the delivery point, and no variance in quantity is permitted. Packaging and palletization must follow DLA’s packaging requirements, and only the specified NSN 6515-01-700-6387 is acceptable. The contract imposes strict accountability through special marking codes, supply chain traceability, and government-only identifying codes, with the primary point of contact being Brooke Webb of the Department of Defense.

General Info

Two Hamilton Medical ventilator batteries, NSN 6515-01-700-6387, FOB destination, 36-month shelf life, FDA Class II, traceable labeling, DLA packaging, no parcel post.

Agency

Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSFView Agency

Contract Value

$464.66

NAICS

339112 - Surgical and Medical Instrument ManufacturingView NAICS

Place of Performance

404 AFSBN CHARLESTON 103 GUIDANCE, GOOSE CREEK, SC, 29445-0000, USA

Set-Aside

NONE

Awardee

HAMILTON MEDICAL, INCView Profile

Award Issued Date

Documents

(1)

SPE2DS-26-T-016A.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
Contacts1 person available
OfficeUSA
Organization / Agency
Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF
View Agency Profile
Office AddressUSA

Full Description

Show more
BATTERY,VENTILATOR
BATTERY,VENTILATOR
APPLICABLE TO ALL MEDICAL ACQUISITIONS:
PACKAGING AND PACKING SHALL BE COMMERCIAL AS
SPECIFIED IN THE PROCUREMENT DOCUMENT.
EACH COMPLETE UNIT SHALL BE PROPERLY PACKAGED
IN A SUITABLE SEALED UNIT CONTAINER CAPABLE
OF PROTECTING THE CONTENTS FROM DAMAGE AND/OR
BREAKAGE.
UNITS SHALL BE PACKED IN SUITABLE COMMERCIAL
EXTERIOR (SHIPPING) CONTAINERS (EXPORT WHEN
NECESSARY) WHICH SHALL INSURE ACCEPTANCE AND
SAFE DELIVERY BY COMMON OR OTHER CARRIER, AT
THE LOWEST RATE, TO POINT OF DELIVERY CALLED
FOR IN THE CONTRACT OR ORDER.
MATERIAL MUST BE MARKED IAW MEDICAL MARKING
STANDARD NO. 1. THIS SUPERCEDES ALL REFERENCES
TO MIL-STD-129.
COPIES OF MEDICAL MARKING STANDARD NO. 1
(MMS NO. 1) MAY BE OBTAINED BY CONTACTING DLA
TROOP SUPPORT VIA EMAIL TO fssb@dla.mil. MMS NO. 1 IS ALSO AVAILABLE ONLINE AT: https://www.dla.mil/Logistics-Operations/Packaging/
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A FOLLOW-ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RQ011: REMOVAL OF GOVERNMENT IDENTIFICATION FROM NON-ACCEPTED SUPPLIES
RD003, COVERED DEFENSE INFORMATION POTENTIALLY APPLIES
This device or drug is regulated by the FDA. Note to Buyers: The contracting official shall send a referral in EBS to the product specialist for confirmation. Please include bidder name and bidder contact information, manufacturer name, manufacturer part number, and item description.
VENTILATOR Regulation 886.5895, Class II.
SPE2DS-26-T-016A
SECTION B
Even though a 510(K) (is/is not) required, it is necessary to meet other requirements for marketing. These include: Registration and Listing, Labeling, or GMP’s.
RS020: Shelf-life requirement RS001 for a TYPE I (CODE Q) item with a shelf life of 36 months (non-extendable) applies to this item.
... SHALL BE MARKED IAW THE LATEST EDITION OF THE MEDICAL MARKING STANDARD NO. 1. MMS NO. 1 IS AVAILABLE ONLINE AT: https://www.dla.mil/Logistics-Operations/Packaging/
SAAB AUSTRALIA PTY LTD Z1BP5 P/N MSP369108 HAMILTON MEDICAL, INC 0U4J3 P/N MSP369108
DLA issues this document using the DoD authorized unit of issue, please refer to the following URL to determine the corresponding ANSI X12 unit of issue.
https://view.officeapps.live.com/op/view.aspx?src=https%3A%2F%2Fwww.dla.mil%2FPortals%2F104%2FDocuments% 2FDLMS%2FeApplications%2FLogDataAdmin%2FUnitofIssueandPurchaseUnit.xlsx&wdOrigin=BROWSELINK
CLIN PR PRLI UI QUANTITY UNIT PRICE TOTAL PRICE.
0001 7016505529 0001 EA 2.000
NSN/MATERIAL:6515017006387
DELIVERY (IN DAYS):0020
DELIVER FOB: DESTINATION
QTY VARIANCE: PLUS 0% MINUS 0%
INSPECTION POINT: DESTINATION
ACCEPTANCE POINT: DESTINATION
PREP FOR DELIVERY:
PKGING DATA MIL-STD-2073-1E
QUP:001 PRES MTHD:ZZ CLNG/DRY:Z PRESV MAT:ZZ
WRAP MAT:ZZ CUSH/DUNN MAT:ZZ CUSH/DUNN THKNESS:Z
UNIT CONT:ZZ OPI:M
INTRMDTE CONT:ZZ INTRMDTE CONT QTY:ZZZ
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
APPLICABLE TO ALL MEDICAL ACQUISITIONS:
PACKAGING AND PACKING SHALL BE COMMERCIAL AS SPECIFIED IN THE PROCUREMENT DOCUMENT.
EACH COMPLETE UNIT SHALL BE PROPERLY PACKAGED IN A SUITABLE SEALED UNIT CONTAINER CAPABLE OF PROTECTING THE CONTENTS FROM DAMAGE AND/OR BREAKAGE.
UNITS SHALL BE PACKED IN SUITABLE COMMERCIAL EXTERIOR (SHIPPING) CONTAINERS (EXPORT WHEN
SPE2DS-26-T-016A
SECTION B
PR: 7016505529 PRLI: 0001 CONT’D
NECESSARY) WHICH SHALL INSURE ACCEPTANCE AND
SAFE DELIVERY BY COMMON OR OTHER CARRIER, AT
THE LOWEST RATE, TO POINT OF DELIVERY CALLED
FOR IN THE CONTRACT OR ORDER.
MATERIAL MUST BE MARKED IAW MEDICAL MARKING
STANDARD NO. 1. THIS SUPERCEDES ALL REFERENCES
TO MIL-STD-129.
COPIES OF MEDICAL MARKING STANDARD NO. 1
(MMS NO. 1) MAY BE OBTAINED BY CONTACTING DLA
TROOP SUPPORT VIA EMAIL TO fssb@dla.mil. MMS NO. 1 IS ALSO AVAILABLE ONLINE AT: https://www.dla.mil/Logistics-Operations/Packaging/
BULK BREAK POINT:
W50YF0
W0DA AFSBN CHARLESTON
ISSA W0DA ASC AWCF
404 AFSBN CHARLESTON 103 GUIDANCE
GOOSE CREEK SC 29445-0000
US
SHIP BY TRACEABLE MEANS. DO NOT USE PARCEL POST.
FREIGHT SHIPPING ADDRESS:
W50YF0
W0DA AFSBN CHARLESTON
ISSA W0DA ASC AWCF
404 AFSBN CHARLESTON 103 GUIDANCE
GOOSE CREEK SC 29445-0000
US
MARKFOR
W50YF0
W0DA AFSBN CHARLESTON
ISSA W0DA ASC AWCF
404 AFSBN CHARLESTON 103 GUIDANCE
GOOSE CREEK SC 29445-0000
US
M/F: (TCN) W50YF061060278
RDD: 121
PROJ: TP 3
SUPP ADD: W9046W SIG: C
FOR GOVERNMENT USE ONLY: (IPD) 13
DIC: A0A DIST: V ADV: 2A FC: Z9
Need Ship Date:00/00/0000 Original Required Delivery Date:04/28/2026
SPE2DS-26-T-016A NSN/Part Number: 6515-01-700-6387 Quantity: 2 EA Purchase Request: 7016505529QTY: 2 Delivery: 20 days ADO

More opportunities from Department Of Defense → MEDICAL SUPPLY CHAIN MD SURG FSF

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS