Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on September 14, 2018. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

300 & 400 Sewer CIPP Lining

Awarded
FA303018B0002Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 237110
New
Morgans Branch Force Main and Pump Station Improvements
Solicitation # SRP-W-134-0290
The Morgans Branch Force Main and Pump Station Improvements project, solicitation number SRP-W-134-0290, is a construction contract for the City of Belmont in North Carolina with a project estimate of 16,690,000 dollars. The scope of work involves the installation of 16,435 linear feet of 20-inch ductile iron force main and extensive upgrades to the Morgans Branch Pumping Station. Key deliverables include the construction of a new wet well and valve vault, the installation of pumps, a generator, odor control equipment, mechanical and electrical systems, and the demolition of existing pumps and piping. The project also encompasses site improvements such as stormwater facilities, fencing, and various paving and restoration activities. The contract will be awarded to the responsible bidder submitting the lowest responsive bid, with specific requirements for the submission of a Good Faith Efforts Form and Table A to meet MBE/WBE participation goals of 10.9 percent for the EPA and 10 percent for the State of North Carolina. Performance and payment bonds, as well as proof of insurance, are required. The project is managed by Willis Engineers, and the contractor will be subject to liquidated damages of 1,000 dollars per day for failure to achieve substantial completion. Payment is processed via Applications for Payment, with funds becoming due 30 days after presentation to the owner. All work must adhere to strict quality standards, including AWWA Specification C-600 for pipelines and NEMA standards for motors.
Don Moorhead Construction, Inc.

POSTED

about 3 hours ago

DEADLINE

in 21 days

AI Contract Overview

Show more

Solicitation FA303018B0002 outlines a project for the Department of Defense to rehabilitate sewer pipelines at Goodfellow Air Force Base in San Angelo, Texas. The contractor is responsible for providing all labor, equipment, and materials to repair approximately 4,663 linear feet of sewer mains using Fold and Form Pipeliners and Cured in Place Pipe lining. The scope of work includes flushing and cleaning pipelines, performing pre- and post-installation CCTV video inspections, installing new manholes, and managing bypass pumping during the process. This project is a 100 percent Small Business set-aside under NAICS code 237110, with an estimated value between 500,000 and 1,000,000 dollars. The required period of performance is 120 calendar days. The awarded contractor and all subcontractors must adhere to all applicable federal, state, and local environmental laws.

General Info

Contract Value

$809,945

NAICS

237110 - Water and Sewer Line and Related Structures Construction

Place of Performance

TX, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Presolicitation

Notice updated

Response deadline changed from Jul 20, 2018 to Aug 27, 2018. The notice description changed. The point of contact changed.

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA3030 17 Cons Cc
Contacts2 people available
OfficeGOODFELLOW AFB, TX, 76908-4705, USA
Office AddressGOODFELLOW AFB, TX, 76908-4705, USA
Contacts
Jake LuceriAdministrator
Micheal ScottContracting Officer

Full Description

Show more
17 CONS/PKA 210 Scherz Blvd Goodfellow AFB, TX 76908-4705 Project Title: 300 and 400 Sewer Lines CIPP Solicitation: FA303018B0002 Goodfellow AFB, San Angelo Texas, requires a contract for the requirement to rehabilitate sewer pipelines by installing Fold and Form Pipeliners (FFP) and a Cure in Place Pipe (CIPP) liner. The contractor shall furnish all plant, labor, equipment, materials, transportation, services, and incidentals necessary to perform all work necessary to: Repair existing sewer main system to include cleaning and video camera of approximately 4,663 linear feet. The sewer mains will be repaired using the Cured in Place Piping (CIPP). There is approximately 51 LF of 4" pipe, approximately 785 LF of 6" pipe, approximately 545 LF of 8" pipe, approximately 3282 LF of 10" pipe, and approximately 125 LF of 15" pipe. Bypass pumping is required during the camera and CIPP process.. The work will include: Rehabilitate sewer pipelines by install Fold and Form Pipelines (FFP) and Cure in Place Pipe (CIPP) liner. 1. Flush and clean sanitary sewer pipelines, as required to remove debris and blockages. 2. Provide CCTV video/Pre-TV inspections of existing conditions for all sanitary sewer pipelines. 3. Submit CCTV video/Pre-TV inspections for Government review and approval. 4. Provide new manholes as described in project drawings. 5. Submit CCTV/Post -TV inspection of the new CIIP for all sanitary sewer pipelines. The general description of work does not in any way limit the responsibility of the Contractor to perform Repair Sanitary Sewer Outfalls, all work, plant, supervision, management, quality control, labor, tools, equipment, appliances and material and performance in strict accordance with the specifications, drawings, and subject terms and conditions of each task order and the main contract. This requirement is being solicited as 100% Small Business set-aside. The magnitude of this work is between $500,000 and $1,000,000. The North American Industry Classification System (NAICS) Code is 237110, Water and Sewer Line and Related Structures Construction, with a Small Business Size Standard of $36.5 Million. The period of performance for this requirement shall be 120 calendar days. The contractor awarded a contract shall comply and ensure all sub-contractors comply with all applicable federal, state, and local laws related to environment matters. The Invitation for Bid is expected to be issued on or around 19 June 2018 with an anticipated bid opending date of 20 July 2018. Oral communications ARE NOT acceptable in response to this notice. Interested parties should register online as interested parties and subscribe to receive procurement announcements related to this solicitation by entering the website at http://www.fedbizopps.gov/. Any questions relating to this solicitation must be submitted in writing, via fax @ (325) 654-5149 or by e-mailing all of the following recipients: jake.luceri@us.af.mil, and micheal.scott.1@us.af.mil referencing "Solicitation FA303018B0002, 300 and 400 Sewer Lines CIPP.

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS