Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Commerce was posted on June 23, 2014. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Building 81/PML Fire Protection Upgrades

Closed
SS_Bldg81_FireProtectionUpgradeFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for transformer oil testing services to enhance the reliability, safety, and maintainability of its transformers. The scope of work is divided into three primary areas: conducting visual and infrared thermographic inspections to identify thermal anomalies, installing standardized external oil sampling devices for safer collection, and performing detailed oil testing analysis. Additionally, the contractor is required to evaluate nitrogen blanket systems to ensure positive pressure is maintained, provide on-site training for agency staff on inspection tools, and develop comprehensive standard operating procedures. All work must adhere to strict technical and safety standards, including ASNT Level 1 certification for thermography, ASTM D923 and D924 for oil sampling, and NFPA 70E safety protocols. The agency intends to make a single award to the most capable and cost-effective offeror, evaluating candidates based on their staffing plan, personnel availability, fee structure, and a proven track record of performing similar projects for utilities or industrial facilities. Proposals must be submitted electronically via PlanetBids by December 23, 2026, and must include a detailed project approach, company profile, and required certifications such as non-collusion and workers compensation. The resulting contract will feature fixed pricing for an initial term with potential one-year extensions. Awardees must comply with California Labor Code prevailing wage requirements and maintain strict confidentiality regarding all agency reports and data.
Inland Empire Utilities Agency

POSTED

about 5 hours ago

DEADLINE

in 2 months
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management and Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves a qualified electrical contractor inspecting, testing, repairing, and certifying emergency lighting systems across the facility, including the cafeteria, recreation building, and dormitories. Key tasks include performing functional tests by simulating utility outages, replacing failed ballasts with LED-compatible versions, and applying durable labels to fixtures for future tracking. The contractor must ensure full compliance with NFPA 101 (2024 Edition) and NFPA 70 standards, integrate recurring maintenance into the center's Computerized Maintenance Management System, and provide certificates of disposal for hazardous materials. The estimated contract value ranges from $25,000 to $100,000, with a performance period of 30 business days following the Notice to Proceed. Bids are due by December 1, 2026, and must include a detailed cost breakout and a mandatory physical site visit. For bids of $25,000 or more, a bid bond of 20% is required, and the awarded contractor must provide performance and payment bonds from a surety with at least an A- rating. This solicitation is set aside for small businesses and various SBA-certified categories. Award decisions will be based on overall best value. Compliance requirements include adherence to the Davis-Bacon Act, Federal Contractor Minimum Wage, and FAR regulations regarding work hours, safety standards, and the Buy American Act.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 5 hours ago

DEADLINE

in about 1 month

General Info

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

325 Broadway, BOULDER, CO, 80305, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Commerce Nist
Contacts2 people available
OfficeGAITHERSBURG, MD, 20899, USA
Organization / AgencyDepartment Of Commerce Nist
Office AddressGAITHERSBURG, MD, 20899, USA
Contacts
Patricia M. BullingtonContract Specialist

Full Description

Show more
Building 81/PML Fire Protection Upgrades This sources sought notice is issued for information and planning purposes only and does not commit the Government to solicit or award a contract now or in the future. No solicitation is available at this time. The purpose of this notice is to identify sources with the requisite qualifications that could provide the products/services stated herein. All businesses, large and small businesses (8(a), SDB, WOSB, HUBZone, VOSB and SDVOSB) capable of performing the requirement indicated below are encouraged to respond to this notice. The National Institute of Standards and Technology (NIST) seek information on commercial vendors that are capable of providing facility fire protection upgrades. The Instrument Labs in the Boulder Precision Measurement Laboratory (PML, Building 81) at the NIST site in Boulder, CO requires smoke detection capability upgrades. Although the current system satisfies minimum code requirements for class B occupancy, a lack of smoke detection impacts mission continuity and increases the physical risk to the occupants, first responders, equipment, and facilities. The affected PML Instrument Labs without smoke detection include the equivalent of more than 160 single modules of advanced lab space (more than 45,000 net assignable square feet), supporting the work of hundreds of scientists, OFPM staff, and facilities contractors, and containing an estimated $140 million in advanced research and measurement equipment, in addition to the approximately $150 million total cost of the PML. Proposed fire detection capability upgrades would include installation of smoke detection in the instrument labs (IL), adjacent corridors, service galley, and interstitial space above the instrument labs. NIST also requires a consolidated user interface for multiple life safety/fire protection systems in the command area in Bldg 81. All design, equipment, and installation must meet the latest edition of NFPA 72. All equipment shall be site standard Notifier equipment. All existing and new Xtralis VESDA detectors in Building 81 shall be compatible with VESDAnet. New equipment needs to be compatible with the ~55 existing Xtralis VESDA detectors. Work will consist of the following tasks: Installation of approximately 25 Xtralis VESDA aspirating detectors that will serve the north labs and mechanical interstitial space located above the labs in Building 81. Lab Service Galleys: an appropriate aspirating smoke detector shall be provided for each of the 5 galleys serving the labs. Each service galley shall have individual monitoring. Pedestrian Corridors: detection for the pedestrian corridors will be spot detectors. The pedestrian corridors consist of the public areas between the lab units as well as the north and west walls. Individually addressed detectors are required. Interstitial Mechanical Space (ambient air): XTRALIS VESDA detection for the interstitial mechanical space ambient air. The existing cleanroom XTRALIS VESDA detection, consisting of 55 XTRALIS VESDA detectors, and new XTRALIS VESDA detectors will also be connected to the campus fire alarm system network. A new display (Notifier FirstVision) will be installed in the lab area for local graphic access to the systems associated with the labs. The Xtralis VESDAnet and Notifier FirstVision user interfaces will be installed in 81-1A111. Qualified businesses are encouraged to respond to this sources sought by providing the following information (1) Company name and DUNS number. (2) Documentation sufficient to demonstrate your company's ability to provide the required products/services. (3) Company size and socio-economic status if applicable (i.e. Large business, Small Business, 8(a), SDB, WOSB, HUBZone, VOSB, SDVOSB, etc.) The applicable NAICS code and small business size standard for this requirement is 238210, and $14 million. All responses are due no later than 5:00 PM MDT, Sunday, July 20, 2014 and must be submitted via email to robert.brackett@nist.gov.

More opportunities from Department Of Commerce Nist

Same awarding agency

NAICS: 236210
New
Federal
Building 215 Clean Room HEPA Filter Replacement
Solicitation # RFI-195000-26-00181
The National Institute of Standards and Technology is conducting market research through a Request for Information for the Building 215 Advanced Measurement Laboratory cleanroom repair and HEPA filter replacement project in Gaithersburg, Maryland. This initiative follows a previous solicitation that failed to produce an acceptable offer, prompting NIST to reassess its acquisition strategy and seek industry feedback on constructability, cost, and schedule feasibility. The project scope involves the modernization of an 1,800 square meter facility, including the replacement of approximately 1,200 HEPA filters, 70 VAV terminal units, and 54 airflow monitoring devices, as well as the installation of 32 exhaust air control valves and associated ductwork repairs, testing, and recertification. A critical component of the project is the proposed phasing plan, which aims to minimize research disruptions by utilizing 19 construction phases, including 18 critical cleanroom outage phases. Each critical outage is currently envisioned as a nine-day window starting Friday evening and requiring 24/7 operations to achieve ready-for-re-occupancy by the following Monday morning. NIST is specifically requesting rough-order-of-magnitude cost estimates and industry input on whether this aggressive outage schedule is realistic or if it creates prohibitive risks and costs. Responses, including company experience and recommendations for improving competition and project execution, are due by October 14, 2026.
Industrial Building Construction

POSTED

2 days ago

DEADLINE

in 12 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS