Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on October 26, 2016. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

C--AE Replace Air Handling Units and Correct Deficiencies Project 583-15-101

Awarded
VA25116R0023Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
Road Asset Management
Solicitation # FY27-ENGCP-002-6
The Bulloch County Board of Commissioners is soliciting Statements of Qualifications for project FY27-ENGCP-002-6, focused on Road Asset Management. The selected consultant will be responsible for collecting and analyzing field data, creating a road asset inventory, and developing a Capital Improvement Plan with an outlook extending to FY 35. The scope includes GIS database development, web-based mapping, and the identification of structural hazards and drainage failures to minimize safety risks and legal liability. All prime and sub-consultants must be GDOT Prequalified Contractors as of the submission deadline on November 20, 2026, at 3:00 PM EDT. Proposals are evaluated based on a composite scoring system that weights prime consultant experience and technical approach at 20% each, GIS capabilities at 20%, asset prioritization methodology at 15%, workload capacity at 15%, and past references at 10%. The highest-ranked consultant will be invited to negotiate a contract. Key requirements include a Principal-in-Charge with at least 10 years of industry experience and comprehensive insurance coverage, including professional malpractice and general liability of at least 1 million dollars per occurrence. Submissions are limited to ten pages, excluding mandatory forms and charts, and must include a Non-Collusion Affidavit and Bidder Declaration. Either party may terminate the resulting agreement with 30 days written notice.
Bulloch County Board of Commissioners

POSTED

about 12 hours ago

DEADLINE

in 21 days
NAICS: 541330
New
International
CoT RFP Event Q30-01-2026-27
Solicitation # Q30-01-2026-27
The City of Tshwane is soliciting a service provider for professional engineering services to support town planning subdivision application processes on city-owned properties. The scope of work is divided into three primary categories: Civil Services Reports, Geotechnical Investigations, and Route Determination Reports. All services must be led by a Professional Engineer registered with the Engineering Council of South Africa and must comply with the Gauteng Transport Infrastructure Act, National Building Regulations SANS 10400, and various SANS and SANRAL standards. The project follows a strict timeline, requiring an inception meeting within one month, draft reports within three months, final reports within five months, and project close-out within six months of appointment. The solicitation, numbered Q30-01-2026-27, closes on November 12, 2026, at 10:00. Awards are based on an 80/20 preferential point system in accordance with the Preferential Procurement Policy Framework Act and 2022 Regulations, with specific goals including points for women-owned, youth-owned, and disability-owned enterprises, as well as local economic participation. Evaluation occurs in four stages, starting with administrative responsiveness and a functionality score of at least 70 out of 100. Successful bidders must enter into a Service Level Agreement, with payment terms set at 30 days following the receipt of an invoice. Required submission documents include company registration, tax clearance or a CSD unique pin, and B-BBEE certification.
City of Tshwane

POSTED

about 14 hours ago

DEADLINE

in 13 days

AI Contract Overview

Show more

This procurement is restricted to Service Disabled Veteran Owned Small Business firms located within a 300 mile radius of the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. The selected Architect/Engineer firm will provide comprehensive design services for Project 583-15-101, which involves replacing and repairing Air Handling Units in an occupied facility. Key deliverables include schematics, construction documents, technical specifications, and a detailed phasing plan to ensure continuous medical center operations with minimal disruption to patient care. The design must prioritize energy conservation, adhere to ASHRAE and VA standards, and include a third-party commissioning and acceptance testing plan. The estimated construction value is between 5 million and 10 million dollars, with a design completion timeline of approximately 228 calendar days. Qualified firms must submit a Standard Form 330 qualification package addressing eight specific selection criteria, including professional qualifications, specialized experience, and past performance. To remain eligible, the prime contractor must ensure that at least 50 percent of the personnel costs are spent on employees of SDVOSB concerns. Selection will be based on a qualifications review followed by interviews with a short list of the most qualified firms.

General Info

Contract Value

$910,459.61

NAICS

541330 - Engineering Services

Place of Performance

OH, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Sources Sought

Type Changed

Sources Sought → Presolicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
ContactsNo contacts available
OfficeDAYTON, OH, 45428, USA
Office AddressDAYTON, OH, 45428, USA
ContactsNo contact information available

Full Description

Show more
This Architect/Engineer procurement is restricted to Service Disable Veteran Owned Small Business (SDVOSB) firms located within a 300 mile radius of the Richard L. Roudebush VA Medical Center, 1481 W. 10th Street, Indianapolis, IN 46202. This requirement is being procured in accordance with the Selection of Architects and Engineers Statute as implemented in FAR Subpart 36.6. Applicable NAICS code is 541330 and small business size standard of $15 Million. The Architect Engineer (AE) firm shall provide architectural and design services necessary to furnish: Schematics, Design Development, Construction Documents, Technical Specifications, Construction Period Services, Site Visits, Cost Estimates, As-Built Documentation, and all other related information for the Project 583-15-101, Replace Air Handling Units and Correct Deficiencies AE Design located at the Richard L. Roudebush, VA Medical Center 1481 West 10th Street, Indianapolis, Indiana as described below: The A/E design firm shall furnish all necessary architectural and engineering resources to provide a complete construction design package for the replacement, repair or refurbishment of the Air Handling Units (AHUs) identified. All AHUs under consideration currently serve different portions of Bldg. 1 which is occupied with patients and staff. The design must allow for the continuous operation of the Medical Center with minimal disruption to the delivery of patient care. For each of the AHUs under consideration, A/E design firm shall address the following: Provide a description of the existing and proposed HVAC systems and equipment, to include the mechanical condition and any functional deficiencies of existing equipment. Investigate the availability of utilities (electricity, steam, or hot water) for the HVAC equipment and provide description of their status. Indicate the tentative locations of proposed HVAC equipment, including any outdoor equipment. Determine the condition and availability of any spare capacity of the existing systems. Include specific recommendations for meeting the HVAC needs of the project in accordance with latest ASHRAE Standards and VA criteria. Describe the tentative zoning of the spaces, including those proposed with dedicated HVAC systems. Describe the locations of the proposed equipment serving each zone, focusing on the serviceability and maintainability of each major piece of equipment. Provide complete engineering criteria and rationale used for selecting a particular HVAC system, including life cycle cost analysis. Coordinate with the VA HVAC Design Manual to determine the restrictions on the system type and capacity limitations. Include all zone level and space level assumptions and parameters to be used in the analysis. Areas with particularly high internal heat loads should be identified as priorities for redesign of existing systems, with the design goal of optimizing outdoor air temperature reset on chilled water supply temperature setpoint. Simultaneous heating and cooling shall be minimized, except where required for dehumidification. Define energy conservation measures proposed to be used in the HVAC system design. Refer to VA guidelines for the mandated energy conservation requirements and energy consumption goals. State the logic and criteria for selecting each conservation measure. Develop a detailed phasing plan for the execution of all HVAC work, to include demolition, equipment placement and coordination with electrical, plumbing, sheet metal, fire alarm, controls and insulation disciplines. Include infection control and life safety procedures. Work to be performed under this contract includes testing the airflow and water flow balance of the AHU, to include system support components, such as heat exchangers, chilled water supply, circulation pumps and all distribution ductwork, including general and dedicated exhaust. Design shall determine if the air supply volume and temperature requirements for specialized areas, such as clinical and research laboratories, operating rooms, intensive care and isolation rooms, sterile processing areas to include storage of sterile goods, contaminated material handling and storage areas, pharmacy and medical supply storage, food storage and preparation, information technology and communications equipment. All AHUs should be replaced with energy saving type AHUs with the possibility of adding heat recovery units to all of the new Air Handling Units. The use of mixed-air units is also an alternative to heat recovery systems depending on the function of the space served. Design will provide for all work to be installed in a manner to allow the least amount of time that temperature control will be unavailable to occupied spaces. No abandonment of existing equipment will be permitted. Design shall provide for the inclusion of any work required to address deficiencies in supporting structures, roofing systems, insulation, electrical connections, relief fan systems, supply and return ductwork placement and transitions, catwalks and equipment access structures, and any lighting, signage and related safety equipment. Positioning, placement, routing and connection for all new ductwork, piping, electrical, structural and control work must be field-verified by AE and any potential rework of existing building systems required to facilitate new work must be presented to the VA COR for approval. The A/E firm shall provide a preliminary construction schedule which shall include a timeline for projected outages highlighting the facility interruption time frame for each affected area. The A/E firm shall provide and present a detailed project work plan, including schedule, explicit phasing directions, space access and occupancy schedules, work schedules to include off-shift, weekend and holiday work requirements, staging and shop areas, construction waste management, infection and noise control, life safety compliance, wall material and finish schedules in areas where demolition of walls for access is required, work turnaround requirements, property protection and cleanup/restoration requirements. For equipment above ground level that requires lifting, a detailed site plan for lifting equipment, whether ground or air based, shall be provided, to include areas requiring evacuation, safety zones and demarcation, placement plans for ground-based equipment including load bearing capability of underground utility systems and soil suitability, overhead utility and obstruction avoidance, circulation plans to include routine and emergency access, pedestrian access control, and time of day/day of week definition to minimize patient care disruption. A detailed Inspection and Acceptance Testing plan will be developed to provide contractors with acceptance milestones and incremental punch list management direction during construction. The intent of this plan is to provide an orderly method for the VA COR to periodically recognize beneficial use of the completed elements of work. The Inspection and Acceptance Testing Plan shall include all requirements for a complete testing and commissioning by a third party firm of all systems affected by this project. As part of this Plan, the requirements for commissioning shall direct the construction contractor that all commissioning work will be performed in accordance with VA standards. Anticipated time for completion of design is approximately 228 calendar days including time for VA reviews. NOTE: A/E shall be responsible for conducting site visits for the purpose of data gathering, investigation and documentation of all existing conditions. Perform such investigations as required to accurately verify all existing conditions. Do not rely solely upon "as built" drawings. VA personnel will provide assistance with investigating the project site where prior experience with equipment and utilities will produce an appreciable advantage. The A/E firm shall be responsible for site review of the existing facility in order to field verify the owner's existing documents and as-built drawings. Any modifications that are required to be made as a result of the site review shall be communicated to VA and corrected by the A/E firm. In accordance with FAR 36.204, the estimated magnitude of the resulting construction price range is estimated to be between $5,000,000 and $10,000,000. Prospective firms are reminded that in accordance with VA Acquisition Regulation (VAAR) 852.219-10, at least 50 percent of the cost of personnel for contract performance of the contract shall be spent for employees of the SDVOSB concern or employees of other eligible service-disabled veteran-owned small business concerns. See VAAR Clause 819.7003 for eligibility requirements regarding Service Disabled Veteran Owned Small Business or Veteran Owned Small Business Set-Asides. Federal Acquisition Registrations require that federal contractors register in the Central Contractor Registration (CCR) database at www.sam.gov and enter all mandatory information into the system. Award cannot be made until the contractor has registered. Offerors are encouraged to ensure that they are registered in SAM prior to submitting their qualifications package. SUBMISSION REQUIREMENTS: Qualified A-E firms are required to respond if interested by submitting one (1) original completed Standard Form 330 qualification package Parts I and II to include all consultants (form available on-line at: http://www.gsa.gov/portal/forms/download/116486) In Section H of Part 1 include information regarding the firms estimating effectiveness (estimated costs vs. actual costs), an organizational chart of the firm, a design quality management plan, and past compliance with performance schedules (original design schedule vs. actual design completion time) for each key design project listed in Section F. All submissions must be bound in some manner (spiral, wire, binder, etc) and include a CD copy of the Standard Form 330 submittal. Prospective firms are required to address all selection criteria within submitted SF330 packages using additional pages as required. Selection criteria shall be in accordance with Federal Acquisition Regulation (FAR) Part 36.602-1 and VA Acquisition Regulation (VAAR) Part 836.602-1 as follows: 1. Professional qualifications necessary for satisfactory performance of required services: The qualifications of all individuals which will be used for these services, including the Project Manager, key personnel and any consultants, will be examined. 2. Specialized Experience: Including technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. 3. Professional Capacity: Ability for the firm in the designated geographic area of the project to accomplish the work in the required time. 4. Past Performance on contracts with the Federal Government, Department of Veterans Affairs and private industry in terms of cost control, quality of work and compliance with performance schedules. Limit past project references to those within the same scope as this advertisement. 5. Geographic Location and Facilities of Working Offices. Location in the general geographic area of the project and knowledge of the locality of the project. The proximity of each firm which would provide the professional services and familiarity with the area in which the project is located will be evaluated. This criterion will apply to the offices of both the Prime Firm and any Consultants. (In accordance with VAAR 805.207, the geographical area is limited to a 300 driving mile radius of Indianapolis, IN). 6. Reputation and standing of the firm and its principal officials with respect to professional performance, general management, and cooperativeness. 7. Record of significant claims against the firm because of improper or incomplete architectural and engineering services. 8. Specific experience and qualifications of personnel proposed for assignment to the project and their record of working together as a team. FAILURE TO CLEARLY ADDRESS ALL EIGHT LISTED EVALUATION CRITERIA AND INFORMATION REQUIRED BY THE SUBMISSION REQUIREMENTS BELOW MAY RESULT IN REJECTION OF SF330. Completed SF330s shall be sent to NCO 11 Contracting Office, Attn: Aaron Lacy, 8888 Keystone Crossing, Suite 1100, Indianapolis, IN 46240, no later than 4:00 p.m. EST, December 17, 2015. Outer envelope or packaging shall clearly identify Solicitation number VA251-16-R-0023. Any request for assistance with submission or other procedural matters shall be submitted via email only (contact@example.gov). No faxed or emailed forms will be accepted. After the evaluation of submissions in accordance with the evaluation criteria listed herein, a 'short list' of three or more of the most highly qualified firms will be chosen for interviews to present their approach to the design to arrive at selection of the firm to enter into negotiations. Award of a Firm Fixed Price contract is anticipated by April/May 2016. This is not a request for proposal. The Government will not pay for nor reimburse any costs associated with responding to this advertisement. The Government is under no obligation to award a contract as a result of this advertisement.

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 541380
New
Federal
Effluent Wastewater Testing - Saginaw VAMC
Solicitation # 36C25027Q0032
The Department of Veterans Affairs Network Contracting Office 10 is soliciting a firm fixed price contract for wastewater effluent laboratory analysis services at the Aleda E. Lutz VA Medical Center in Saginaw, Michigan. This procurement is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 541380. The scope of work requires the contractor to provide all labor, equipment, and supervision for the preparation, collection, storage, and transportation of wastewater effluent samples, as well as the performance of analytical testing and the provision of consultative services. All analysis must comply with 40 CFR Part 136, with specific requirements for PCB testing per the City of Saginaw Total PCB Minimization Program and mercury testing per Method 245.1. Formal analytical reports must be delivered to the facility GEMS Coordinator within seven business days of sampling. To be eligible for award, offerors must demonstrate at least three years of experience in wastewater effluent laboratory testing and one year of experience in sample collection, storage, and transportation. Additionally, a signed certification regarding limitations on subcontracting is mandatory for evaluation. The contractor is required to maintain a Quality Assurance Program and adhere to OSHA safety standards, as well as the City of Saginaw Code of Ordinances and Northwest Utilities Authority regulations. Performance is scheduled to begin on December 1, 2026, with invoicing submitted semi-annually or upon completion of service. The government will monitor performance based on turnaround times, customer service responsiveness, and the accuracy of quality control results.
Testing Laboratories and Services

POSTED

about 21 hours ago

DEADLINE

in 7 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS