Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 6, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

C1AZ--Perform Study to Correct Deficiencies at Domestic Water Tanks

Closed
36C24823R0152Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
2026 CPRG NCD SOQ
Solicitation # 2026-SOQ-004
The City of Rogers is soliciting Statements of Qualifications (SOQ) under solicitation number 2026-SOQ-004 for Natural Channel Design services to restore approximately 4,200 linear feet of stream in an urban setting. The scope of work includes engineering, plan design, hydrologic and hydraulic modeling, and the procurement of all necessary local, state, and federal regulatory permits, including potential Letter of Map Revision submissions to FEMA. This project is funded by the Climate Pollution Reduction Grant (CPRG) subaward CPRG-NWA-001 and EPA award 02F75801, requiring compliance with EPA nondiscrimination regulations, Title VI of the Civil Rights Act of 1964, and 40 CFR Parts 5 and 7. Key milestones include the completion and approval of construction plans and permit applications by May 1, 2027, with final construction completion targeted for December 31, 2027. Selection is based on a ranking of qualifications rather than price, with the highest-ranked firm invited to negotiate a contract. Evaluation criteria focus on professional staff expertise, past performance, understanding of the scope, and the quality of the work plan. Interested firms must submit a PDF via OpenGov or hard copy to Colt Craig by November 10, 2026. Submissions are limited to 25 pages and must include Standard Form 330 Part II, an Equal Employment Opportunity policy, the Arkansas DFA Illegal Immigrant Contractor Disclosure Form, and EPA certifications regarding debarment and lobbying for contracts exceeding 100,000 dollars. Additionally, firms must maintain active registration in SAM.gov and demonstrate a commitment to DBE goals through six good faith efforts in subcontracting per 40 CFR 33.301.
Community Development

POSTED

about 6 hours ago

DEADLINE

in 12 days
NAICS: 541330
New
International
Pump Optimisation and Aeration Efficiency Analysis
Solicitation # FA2253
Thames Water Utilities Limited is establishing a single-lot, sole-supplier framework agreement under solicitation FA2253 for pump optimisation and aeration efficiency services. The contract focuses on the monitoring, testing, and analysis of pumping and aeration systems across approximately 60 operational sites, encompassing roughly 200 tests during the AMP period. The primary objective is to reduce whole-life costs and improve operational performance through a structured delivery model that includes site identification, efficiency studies, and performance monitoring. The agreement will feature fixed pricing structures based on an agreed rate card and will be managed through key performance indicators to ensure strategic partnership and continuous improvement. The contract is scheduled for an initial three-year term starting May 10, 2027, with potential extensions up to a maximum of eight years, ending May 9, 2035. Eligible suppliers must demonstrate a proven track record of delivering measurable savings and innovation and must have the capacity to operate within London, the Thames Valley, and the Home Counties. Award selection is based on a 50% technical and 50% commercial weighting. The procurement process is a multi-stage procedure requiring a Pre-Selection Questionnaire via SAP Ariba by October 19, 2026, followed by an Invitation to Negotiate stage. Successful providers must also meet stringent insurance requirements, including 15 million pounds for public and products liability and 10 million pounds for professional indemnity.
Thames Water Utilities Limited

POSTED

about 6 hours ago

DEADLINE

N/A

General Info

NAICS

541330 - Engineering Services

Place of Performance

FL

Set-Aside

SBA

Documents

3

Site Plan (672-23-114) Perform Study to Correct Deficiencies

PDF, High priority: read this firstspecifications
High

Sources Sought Notice for Study to Correct Deficiencies at Domestic Water Tanks - Solicitation 36C24823R0152

DOCX, High priority: read this firstsources-sought
High

SOW - Perform Study to Correct Deficiencies at Domestic Water Tanks (Project # 672-23-114)

PDF, High priority: read this firstsow
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)
Contacts1 person available
OfficeTAMPA, FL, 33637, USA
Office AddressTAMPA, FL, 33637, USA
Contacts
Jaimee MorganContract Specialist

Full Description

Show more
THIS IS A SOURCES SOUGHT NOTICE AND REQUEST FOR STANDARD FORM (SF) 330s ARCHITECT-ENGINEER (AE) QUALIFICATION PACKAGES ONLY. THIS IS NOT A REQUEST FOR A/E FEE PROPOSALS. NO ADDITIONAL SOLICITATION PACKAGE OR TECHNICAL INFORMATION WILL BE ISSUED. THE GOVERNMENT WILL NOT PAY NOR REIMBURSE ANY COSTS ASSOCIATED WITH RESPONDING TO THIS REQUEST. THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. All information needed to submit SF330 documents are contained herein. Federal Acquisition Regulations (FAR) subpart 36.6, and Selection of Architects and Engineers Statute (formerly known as Brooks Architect-Engineer Act) selection procedures apply. The AE Services listed herein is being procured in accordance with Selection of Architects and Engineers Statute as implemented in FAR subpart 36.6 and VAAR 836.6. Pursuant to FAR 52.236-25, the firm responding to this requirement must be permitted, by law, to practice the professions of architecture or engineering and meet all required qualifications for the Commonwealth of Puerto Rico. For a Small Business to be considered as a prospective offeror/contractor, the firm including Joint Ventures, must be verified, and registered in the System for Award Management (SAM) database (www.sam.gov) at time of submission of their SF330s/qualifications. Failure of a prospective Small Business to be verified in SAM at the time the SF330 is submitted shall result in elimination from consideration. FAR subpart 19.5 addresses small business set asides. PROJECT NUMBER: 672-23-114 PROJECT TITLE: Perform Study to Correct Deficiencies at Domestic Water Tanks WORK LOCATION: VA Caribbean Healthcare System, San Juan, PR SET-ASIDE: Total Small Business NAICS: 541330 Engineer Services and the annual small business size standard is $22.5M TYPE OF CONTRACT CONTEMPLATED: Firm-Fixed Price ESTIMATED COMPLETION DATE: The anticipated completion of this project is 184 calendar days after the Notice to Proceed (NTP). Approximate time frames for each submission are presented below: Begin Schematic Design (Notice to Proceed): NTP Submission of Iterations (SD): NTP + 45 Days First Submission of Study report (SD 25%): NTP + 75 Days First Review Meeting and Return First Submission: NTP + 105 Days Second Submission (Design Development 1) (DD1 35%): NTP +135 Days Final Bid Set Submission: 184 Days POINT OF CONTACT: Jaimee Morgan, Contract Specialist, Email: contact@example.gov. SF 330 DATE OF RECEIPT/DUE DATE: Interested firms having the capabilities to perform this work must submit one (1) electronic SF 330 and attachments (if any) no later than (NLT) 3:30 PM Eastern Standard Time (EST) August 4th, 2023. The VA s email system will not allow for file sizes greater than 8MB. If sending multiple emails, please see directions provided further down in this notice. Site Visits will not be arranged during this phase. PROJECT OVERVIEW: This A/E services project will furnish all necessary professional services, equipment, labor, materials, supervision, tools, testing, and specialty services to perform design services for project number 672 23 114, Perform Study to Correct Deficiencies at Domestic Water Tanks at the VA Caribbean Healthcare System (VACHS), located at 10 Casia Street, San Juan, Puerto Rico 00921 3201. The A/E Service works include, but is not limited to site investigations, all necessary inspections, survey and evaluation of the existing study site, verification of existing drawings, and comprehensive research. This project is to provide engineering design services and perform a study to determine the deficiencies of the two 1-Million-gallon domestic water tanks (T1 & T2), the corrections needed, the feasibility of performing repairs to the tanks, and develop detailed as built drawings and construction cost estimates to repair these deficiencies. This study shall include a thorough evaluation of the site and tank foundation, the tank shell condition at the exterior and interior, and all necessary studies to ensure that the current structural integrity of the tanks is not compromised by corrosion. ***PROJECT OVERVIEW END*** A/E FIRM SELECTION: Firms responding to this announcement by submitting a qualifying SF 330, before the closing date and time, will be considered for initial selection evaluation. Following initial evaluation of the SF330s received, three or more firms that are considered the most highly qualified to provide the type of services required will be selected for interviews. Selected firms will be notified by email of selection and provided further instructions. Selection and evaluation of firms shall be made based on SF330 submissions and direct responses to the selection criteria identified herein. Failure to address all selection criteria will result in a decreased rating. Firms that design or prepare specifications in conjunction with this contract are prohibited from participating on any future construction contracts based on those documents. All projects identified on the SF330 must be completed by the office/branch/individual team member performing the work under this contract. SELECTION CRITERIA: Selection will be based on the following criteria which are provided with equal importance. PROFESSIONAL QUALIFICATIONS Specific qualifications needed include (i.e., education, training, registration, certifications, overall relevant experience, and longevity with the AE firm) of personnel proposed for assignment to the project. The project architect or engineer of record must be licensed to practice in the Commonwealth of Puerto Rico under local law requirements. Submit legible copy of Commonwealth of Puerto Rico valid professional Engineer or Architect license of the architect-engineer of record. Identify on SF 330, Part I - Contract-Specific Qualifications, Section D. Organizational Chart of Proposed Team, the architect-engineer of record designated to this project. The Designer of Record must have at least five (5) years of experience with physical plants. Submit record of working together as a team for the personnel proposed for assignment on this project. Also submit the types and number of projects the AE firms (or design team members) have worked together on over the past five (5) years. SPECIALIZED EXPERIENCE AND TECHNICAL COMPETENCE Specialized experience and technical competence in the type of work required, including where appropriate, LEED certification, as well as experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Specialized experience and technical competence will be evaluated based on the design team members knowledge, both individually and collectively as a team, in all types of constructions, renovations, and/or studies. AE Firms must submit at least five (5) but up to seven (7) similar designs for projects involving new construction and renovations inside medical facilities. Designs must be at least 75% complete prior to the release date of the sources sought notice. AE Firms (or design team members) will be evaluated on their processes in relation to design quality management procedures, Computer-Aided Design, and Drafting/Building Information Modeling, Building Information Modeling, equipment resources and laboratory requirements for the AE firm and any proposed subcontractors. AE Firms (or design team members) will be evaluated on their experience at incorporating sustainability principles into designs and evaluations, descriptions of waste reduction techniques and energy efficiency in facilities designed by the team, as well as familiarity with the use of recovered materials on construction contracts. CAPACITY Capacity to accomplish the work in the required time. Submit project lists for designs in progress or completed by the personnel proposed for assignment to the project; Indicate how the team accomplishes multiple, large, and small projects simultaneously, at different locations, within required timeframes over the last five (5) years. The number of and types of employees (prime and subcontractor), including the availability of additional competent, regular employees for support of projects, and the depth and size of the organization. Submit information on the volume of work awarded during the previous 12 months to the prime and all subcontractors. RELEVANT PAST PERFORMANCE Past performance on contracts with Government agencies and the private industry in terms of cost control, quality of work, and compliance with performance schedules. The Government will evaluate the AE firm s past performance and any subcontractors to determine the degree to which it demonstrates the likelihood it can successfully perform the requirements of the work as described in the Statement of Work. To be considered recent past performance, the contract shall either be currently active with at least 75% completion or completed within the past five years of the posting date of this notice. In the case of a joint venture, LLC, or other team arrangement formed for the purpose of competing for this contract, the Government will evaluate relevant past performance of the entities that comprise the newly formed entity. Relevant past performance includes current or past contracts similar in size (dollar value), scope (type and nature of work), and complexity (duration, and/or risk) to the work described herein. The Government will use information either furnished by the Offeror and reference(s) and/or information obtained from other independent data sources in evaluating relevant past performance. Submit performance ratings on completed projects. Experience working in VA medical facilities is preferred, however, previous work on other Government, as well as private sector projects, will be considered. For AE firms without a record of relevant past performance or for whom relevant past performance information is not available, the AE firm will not be evaluated favorably or unfavorably. LOCATION It is expected that your SF 330 submittal will show your knowledge of the location in general geographical area of the project, knowledge of the locality of the project, and knowledge of state/local requirements (e.g., regulations, codes, standards) as it relates to this project. Also demonstrate your proximity to the general geographical area enables you to physically show up to the work site within 5 hours, when required. REPUTATION AND STANDING Provide a narrative of the Firm s reputation and standing including principal officials with respect to professional performance, general management, and cooperativeness (Awards, Outstanding Merits, Recommendations). RECORD OF SIGNIFICANT CLAIMS Provide a narrative of the Firm s record of significant claims against the firm because of improper or incomplete architectural and engineering services. If no record of significant claims against the firm because of improper or incomplete architectural and engineering services, please specify. SUBMISSION CRITERIA/REQUIREMENTS: Interested firms having the capabilities to perform this work must submit: ONE (1) ELECTRONIC SF 330, including Parts I and II, and attachments (if any) electronically to contact@example.gov no later than 3:30 PM (EST) on August 4th, 2023. Submittals received after the date and time identified will not be considered. All SF 330 submissions shall be clearly indicated in subject line, displaying the RFP number and project title (abbreviated and shortened is okay), Size limits of emails are limited to 8MB. If more than one email is sent, please number emails in Subject line as 1 of 2, 2 of 2 etc. Example: SF 330 Submission 36C24823R0152 Perform Study to Correct Deficiencies at Domestic Water Tanks (1 of 4). All SF 330 submissions must include the following information either on the SF 330 or by accompanying document: Cover Page with: Solicitation Number Project Title DUNS # Cage Code Unique Entity ID Tax ID Number The Email address and Phone number (with area code) of the Primary Point of Contact Signed cover letter Table of Contents SF 330 signed Responses to all the selection criteria Copy of Current A/E License including a copy of Commonwealth of Puerto Rico valid professional Engineer or Architect license of the architect-engineer of record REQUESTS FOR INFORMATION (RFI) ON THIS SOURCES SOUGHT NOTICE: All RFIs shall be submitted to contact@example.gov. Phone inquiries will not be accepted. RFI s must be received no later than July 14th, 2023. The firm and/or principals representing the project must be licensed in the Commonwealth of Puerto Rico, IAW State law and must meet all licensing requirements to sign and seal drawings. Examples of information resources are: Gobierno de Puerto Rico Departamento de Estado Puerto Rico Professional Engineering Certificate of Authorization: https://www.ncarb.org/get-licensed/state-licensing-boards/architect-lookup https://estado.pr.gov/en/engineers-and-surveyors/ https://www.estado.pr.gov https://www.ncarb.org/get-licensed/licensing-requirements-tool https://estado.pr.gov/en/architects-and-landscape-architects/ NCARB rules for all States and PR/VI on architectural licensing: https://www.ncarb.org By responding to the Notice, you are acknowledging that your company meets the status requirements as a Small Business concern. SEE ATTACHED DOCUMENTS FOR THE SOW AND OTHER DOCUMENTS: ATTACHMENT 01 SOW (672-23-114) Perform Study to Correct Deficiencies at Domestic Water Tanks (10 Pages). ATTACHMENT 02 Site Plan (672-23-114) (1 Page).

More opportunities from Department Of Veterans Affairs → 248-NETWORK Contract Office 8 (36C248)

Same awarding agency

NAICS: 621399
New
Federal
Q524--FY27: Perfusionist Services| NFSG
Solicitation # 36C24827Q0013_1
The Department of Veterans Affairs, Network Contracting Office 8, is soliciting quotes for onsite Perfusion and Autotransfusion services to support the Malcom Randall VA Medical Center in Gainesville, Florida. This procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The requirement specifies a staffing level of five full-time equivalents, comprising four perfusionists and one autotransfusionist, with each position totaling 2,080 hours per year. The contract includes a base year and three subsequent option periods extending through January 6, 2031. Award will be based on a best-value determination where technical qualifications and past performance are significantly more important than price. Evaluation focuses on candidate qualifications, experience, and the contractor's staffing and contingency plans. The contractor must ensure all personnel meet national standards established by the American Board of Cardiovascular Perfusion and comply with strict quality assurance measures, including a requirement for perfusionists to be onsite or within 30 minutes of the facility during all scheduled operating room hours. Administrative requirements include monthly invoicing in arrears via Tungsten Automation and the submission of monthly performance reports by the 10th of each month. The contractor is responsible for providing medical liability insurance and ensuring all personnel undergo proper vetting, credentialing, and blood-borne pathogen training. Compliance with VA cybersecurity directives and HIPAA privacy regulations is mandatory, with strict liability for any breaches of patient confidentiality.
Offices of All Other Miscellaneous Health Practitioners

POSTED

about 9 hours ago

DEADLINE

in 15 days
View Details
NAICS: 339112
New
Federal
J065--Copy of FY26: MBC Sternudrive LiteTM; Model MBC 709-Modular
Solicitation # 36C24827Q0095
The Department of Veterans Affairs Network Contracting Office 8 is conducting market research through a Sources Sought Notice to identify qualified businesses capable of providing the De Soutter Medical MBC Sternudrive Lite Model MBC 709-Modular or an equal alternative for the VA Caribbean Healthcare System in San Juan, Puerto Rico. This notice is for research purposes only and does not constitute a formal solicitation or an obligation to award a contract. The government has a preference for domestic products that meet or exceed the salient characteristics of the brand-name equipment. The required items include three MBC 709-Modular handpieces, three reciprocating sternum saws, three sternum guards, three oscillating sagittal sternum saws, four large battery packs, and three sterilization systems. Interested businesses must be registered in the System for Award Management and fall under NAICS code 339112 for Surgical and Medical Instrument Manufacturing, which has a size standard of 1,000 employees. To respond, companies must submit a qualifications letter to Darrin Alexander by November 12, 2026, at 13:00 EST. The submission must include the company's name, address, point of contact, UEI code, socio-economic category, and a capability statement with evidence of past or current contracts for similar requirements. Responses must be sent via email with the subject line RFI# 36C24827Q0095 FY 26: MBC Sternudrive LiteTM; Model MBC 709-Modular.
Surgical and Medical Instrument Manufacturing

POSTED

about 9 hours ago

DEADLINE

in 14 days
View Details
NAICS: 236220
New
Federal
5680--FY27 NRM (PROJ 573-24-110) BB - Expand Cardiology Service
Solicitation # 36c24826r0124
Solicitation 36C24826R0124 is a firm-fixed-price requirements contract issued by the Department of Veterans Affairs Network Contracting Office 8 for the renovation and expansion of the Cardiology service administrative space at the Malcom Randall VA Medical Center in Gainesville, Florida. The project involves approximately 6,000 square feet of construction on the third floor of Building 1, encompassing selective demolition, site preparation, architectural finishes, and comprehensive mechanical, electrical, plumbing, fire protection, and technology systems work. The estimated project magnitude is between 2,000,000 and 5,000,000 dollars, with a base performance period of 540 to 548 calendar days from the Notice to Proceed. This procurement is strictly set aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Award will be determined using a trade-off process where technical factors—including relevant past performance, technical approach, project planning, safety, infection control, quality control, and project schedule—are combined and weighted approximately equal to price. Offerors must submit a bid guarantee of 20 percent of the bid price or 3,000,000 dollars, whichever is less, and provide a current Experience Modification Rate (EMR) of 1.0 or less. Due to the operational hospital environment, strict adherence to ICRA/PCRA controls, safety protocols, and minimal disruption to services is required. The closing date for the receipt of proposals has been extended to November 16, 2026, at 3:00 PM EST.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 18 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS