Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on July 11, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

C1DA--528A5-22-506 DESIGN REPLACE BUILDING 118 FAN COIL UNITS

Awarded
36C24223R0119Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Department of Veterans Affairs awarded contract 36C24224C0097 to Miller-Remick, LLC for $451,969.00 to provide complete architect-engineering design services at the Canandaigua VA Medical Center in New York. This project, identified as Project 528A5-22-506, focuses on the replacement of fan coil units within Building 118, which houses the Engineering department and maintenance shops. The scope of work includes the removal of existing fan coil units, Daikin VRF cooling systems, Mitsubishi mini split units, and abandoned heat recovery systems, as well as the installation of new 4-pipe FCUs, a rooftop cooling unit for office spaces, and a standalone chiller with necessary structural evaluations and roofing repairs. The comprehensive design requirement encompasses preliminary concepts, program development, investigative services, and the preparation of contract drawings and specifications. The selected firm is responsible for performing heating and cooling load calculations, designing hydronic systems and electrical work, and ensuring all plans comply with VA Master Specifications and various building codes. The project was 100 percent set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and involved an estimated construction magnitude between 1 million and 5 million dollars.

General Info

Contract Value

$462,595

NAICS

541330 - Engineering Services

Place of Performance

NY, USA

Set-Aside

SDVOSBC

Award Issued Date

Documents

1

Award 36C24224C0097 - Design Replace Building 118 Fan Coil Units

DOCX, Low priorityaward
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseAwarded
Posted

Sources Sought

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Nicholas WinneContracting Officer

Full Description

Show more
DESCRIPTION: This is a Sources Sought-Pre-Solicitation Notice for the establishment of an Architect-Engineering (A-E) contract with services to be performed at the Canandaigua VA Medical Center, 400 Fort Hill Ave, Canandaigua, NY 14424. This requirement is 100% set-aside to Small Disabled Veteran Owned Small Business (SDVOSB) firms. THIS ANNOUNCEMENT IS NOT A REQUEST FOR PROPOSAL; NO SOLICITATION PACKAGE WILL BE ISSUED UNTIL AFTER AN EVALUATION HAS BEEN MADE ON THE PROVIDED SF-330s. The SF-330 can be downloaded through the GSA Forms Library at: http://www.gsa.gov/portal/forms/type/TOP, scroll down to locate and click on the SF-330 hyperlink entitled, Architect-Engineer Qualifications. VA intends to award an Architect/Engineer contract for complete design services (preliminary concepts and layouts, program development, investigative services, preparation of contract drawings and specifications, cost estimating services, and construction period services) for the Design Fan Coil units in Building B118, Project# 528A5-22-506. The area of consideration is restricted to firms with offices and key personnel to be assigned to the design located within a 400-mile radius of the Canandaigua VAMC site as indicated by a mapquest.com driving directions search from the prime designer s main or satellite office address to the project site. Written questions pertaining to this requirement should be submitted no later than 12:00 PM. Eastern Daylight Time (EDT), October 23, 2023. Interested firms should submit their current SF-330, Parts I and II, to Nicholas.Winne@va.gov. The SF-330s are due no later than 4:00 PM, EDT, November 01, 2023. SCOPE OF WORK The general scope of this project is to replace the existing fan coil units in building B118, VA Engineering department and shops. This project includes the removal of all the existing fan coil units in building 118 (A/E to verify the number and the location of all the equipment to be removed during their site verification process). Removal of the existing Daikin VRF cooling system, Mitsubishi mini split units, existing suspended ceiling, lighting fixtures, and abandon heat recovery system including all the duct work. Installation of new 4-pipe FCUs to the maintenance shops replacing the existing units, the makeup air will be reconnected to existing duct work. Replace the existing 2 pipe FCU located in the corridors of building 118. Installation of new rooftop cooling unit with duct work, VAVS, controls, and electrical for the office space (3000 SF approximately). Installation of a standalone chiller, concrete pad, piping, and electrical supporting the cooling load of B118. Work shall include not limited to running a complete Heating/ Cooling load calculation to determine the required capacities and sizing the HVAC system components. Work shall include designing all the duct work, hydronic system, air terminal units (CAVs, VAVs, volume controls dampers, rehear coils, etc.), controls and any required electrical work, add to that, design to include any fixing the existing roofing as needed, including but not limited to roofing patching to match the existing condition and the roofing recertification. The A/E firm will have to evaluate B118 structurally to determine if the building have enough structural capacity to place the new HVAC equipment on the roof, or otherwise come up with options where to locate the new equipment. The office spaces shall receive new suspended ceiling ACT system. New 24 X 24 LED lighting panels to be installed in the office spaces. Remove the existing wall mounted lovers used to provide outside air to the existing FCU s to be removed, infill the existing openings with brick to match the existing exterior wall finish. All designs will follow, but not be limited to, VA Space Planning Specifications, in conjunction with the VA Master specifications as outlined in VA Handbook 7610. The design will be completed in a manner such that the estimated construction cost is within the VA budget. EXISTING CONDITIONS The Canandaigua VAMC is a campus facility with many (more than 30) buildings located on over 150 acres. Many of the facility buildings are included on the historic register. Building 118 (11766 SF approximately) is used by the FMS and it included the Engineering department, which occupying the office spaces and the FMS maintenance shops. A/E SCOPE OF SERVICES Provide investigative and schematic design services, construction documents, working drawings, specifications, cost estimate, shop drawing review and construction period services as required to Replace B118 FCU s. Provide a detailed asbestos and lead survey to construct an NFPA/Life Safety Code and an all-building code compliant project. Provide any asbestos abatement services during construction as needed. Services will include all Site/Civil, Mechanical, Electrical or other Engineering or Architectural work associated with this project. Provide for necessary additions and relocations of all utilities to support the project and operations outside the construction area. All aspects of the design must adhere to the design manuals posted on the VA technical information library (see below). Final design submission shall include phased drawings of all abatement, demolition, and construction work as required to allow the continuous use of all of the floors and areas associated around each construction area. Provide contract specifications utilizing as a template the VA Master Specifications available at www.cfm.va.gov/TIL/. Edited specifications are to be provided to the Canandaigua VAMC electronically by either email or on a CD rom. All edited specifications shall be edited to the specified project and have all impertinent specs and information removed. The designer shall provide to the VAMC a comprehensive electronic spreadsheet listing, by specification, all required submittals for the project for use as a submittal log. The VA will be using Autodesk Build to be used for submittals and contract document exchange. Attend design review meetings and make all necessary site visits during design to gather information necessary from the existing sites, building plans, utility plans, etc. to provide a complete assessment of the proposed work. This should include an identified number of visits included in the proposal. The VA shall provide access to hardcopy files of existing drawings, and the AE shall perform all searches of these files for any required reference materials to support design efforts. Assess the intent and scope of this project and work with the Medical Center staff to develop a final design and cost estimate to best suit the needs and constraints of the government, while incorporating VAMC Canandaigua Engineering Service, VA Network 2, or any other government comments. The design must, at a minimum, be in accordance with all applicable codes indicated in the Department of Veterans Affairs (VA) Design Manuals and VA Publications (Master Construction Specifications, Construction Standards, National Fire Protection Association (NFPA), Underwriters Laboratory, International Building Code IBC 2003, NFPA and National Electric Code (NEC), building codes and standards, and VA Information Security Handbook 6500.6, etc.). A/E Design Deliverables: The deliverables below are required: OFFERORS WILL BE EVALUATED ON THE FOLLOWING CRITERIA: The submitted SF-330s will be evaluated on the following criteria: This acquisition will be in accordance with FAR Part 36.602-1 and VAAR Part 836.602-1. The following evaluation criteria will be used to evaluate SF-330 technical proposals: The A/E must demonstrate its qualifications with respect to the published evaluation criteria for all services. Evaluation Criteria (1) through (4) are considered most important and equal among themselves; Criteria (5) and (6) are of slightly less importance than (1) through (4) but are equal value among themselves; Criteria (7) are the least important and listed in descending order of importance. Specific evaluation criteria include: 1. Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. 2. Professional Qualifications necessary for satisfactory performance of required services. 3. Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates shall be included as an evaluation criterion when construction period services is included in the statement of work for A-E services. 4. Past Performance on contracts with Government agencies and private industry in terms of cost control, quality of work and compliance with performance schedules. 5. Capacity to accomplish the work in the required time. 6. Location in the general geographical area of the project and knowledge of the locality of the project; provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project. 7. The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. Criterion 1 - Specialized experience and technical competence in the type of work required, including, where appropriate, experience in energy conservation, pollution prevention, waste reduction, and the use of recovered materials. Offerors will be evaluated on specialized experience and technical competence in the performance of services similar to those anticipated under this contract regarding: o Experience with design HVAC distribution systems. o Experience with performing building load analysis, sizing and selecting mechanical equipment. o Experience with performing MEP designs. o Experience in providing post construction award services (shop drawing review, as-built drawing, and Quality Assurance Plan (QAP) preparation, construction inspection services, and Operating and Maintenance Manuals). o Experience with government designs and construction. Submission requirements: Provide up to five (5) projects completed or substantially completed within the past five (5) years that best illustrate specialized experience of the proposed team in the areas outlined above. Example projects shall note project s square footage. All projects provided in the SF-330 must be completed by the office/branch/regional office/individual team member proposed to manage and/or perform work under this contract. To enable verification, firms should include the DUNS number along with each firm name in the SF-330 Part 1, Section F Item 25 Firms from Section C Involved in this Project, block (1). Include a contract number or project identification number in block 21. Include an e-mail address, and phone number for the point of contact in block 23(c). Include in the project description the contract period of performance, award contract value, current contract value, a summary of the work performed that demonstrates relevance to specialized experience as outlined above. If the contractor served as a subcontractor on a project, indicate the value of the work they provided towards the performance of the overall project. If a project was performed by a joint venture, and not all joint venture partners are on the team proposed for this contract, the offeror/team should specifically address the work performed by the joint venture partner offering/teaming on this contract. Likewise, if the offeror/team member worked as a subcontractor on a project, the description should clearly describe the work performed by the offeror/team member and the roles and responsibilities of each on the project, rather than the work performed on the project as a whole. If the project description does not clearly delineate the work performed by the entity/entities offering/teaming on this contract, the project could be eliminated from consideration. NOTE: If the Offeror is a joint venture, information should be submitted as a joint venture; however, if there is no information for the joint venture, information should be submitted for either joint venture partner, not to exceed a total of five (5) projects for this criterion. Projects shall be submitted on the SF-330. For submittal purposes, a task order on an IDIQ contract is considered a project, as is a stand-alone contract award. Do not list an IDIQ contract as an example of a completed project. Instead, list relevant completed task orders or stand-alone contract awards that fit within the definition above. Examples of project work submitted that do not conform to this requirement will not be evaluated. Failure to provide requested data, accessible points of contact, or valid phone numbers could result in a firm being rated lower. All information for Criterion 1 should be submitted in Part 1, Section F of the SF-330. The Government WILL NOT consider information submitted in addition to Part 1, Section F in evaluating Criterion 1. Criterion 2 - Professional Qualifications necessary for satisfactory performance of required services. Offerors will be evaluated in terms of the qualifications, competence and experience of the key personnel and technical team proposed to accomplish this work. Key personnel are individuals who will have major contract or project management responsibilities and/or will provide unusual or unique expertise. Provide a balanced licensed and or certified workforce in the following disciplines Architecture, Structural, Mechanical, Electrical, Plumbing, Acoustical, Environmental services and Fire Protection Engineering Submission requirements: Provide resumes for all proposed key personnel. Resumes are limited to one page each and should cite project specific experience and indicate proposed role in this contract. Provide professional registration, certification, licensure and/or accreditation. Indicate participation of key personnel in example projects in the SF-330 Part 1 Section G. Criterion 3 - Experience in construction period services to include professional field inspections during the construction period, review of construction submittals, support in answering requests for information during the construction period, and support of construction contract changes to include drafting statements of work, and cost estimates. Submission requirements: Offerors shall submit evidence of construction period services performed during example projects from Criterion 1. Include specific services in Section F, block 24 performed for that project. Explain your plan to process material submittals/ shop drawings, answer RFIs, conduct site inspection visit during the construction period, also, explain your plan for rapid response if requires at the event of construction emergencies and immediate actions to be taken. Criterion 4 - Past Performance Offerors will be evaluated on past performance with Government agencies and private industry in terms of work quality, compliance with schedules, cost control, and stakeholder/customer satisfaction. Evaluating past performance and experience will include information provided in Past Performance Questionnaires (PPQs) or CPARS/ACASS for Criterion 1 projects and may include other information provided by the firm, customer inquiries, Government databases, and other information available to the Government including contacts with points of contact in other criteria. Failure to provide requested data, accessible points of contact, or valid phone numbers could result in a firm being rated lower. NOTE: Past performance information for projects listed under Criterion 1. Submission requirements: SUBMIT A COMPLETED CPARS/ACASS EVALUATION FOR EACH PROJECT UNDER CRITERION 1. IF THERE IS NOT A COMPLETED CPARS/ACASS EVALUATION, the Past Performance Questionnaire (PPQ) included in this notice is provided for the offeror or its team members to submit to the client for each project the offeror includes under Criterion 1. AN OFFEROR SHALL NOT SUBMIT A PPQ WHEN A COMPLETED CPARS/ACASS IS AVAILABLE. IF A CPARS/ACASS EVALUATION IS NOT AVAILABLE, ensure correct phone numbers and email addresses are provided for the client point of contact. Completed PPQs should be submitted with your SF-330. If the offeror is unable to obtain a completed PPQ from a client for a project(s) before the response date set forth in this notice, offerors should complete and submit with their responses the first page of the PPQ (Attachment), which will provide contract and client information for the respective project(s). Offerors may submit a PPQ previously submitted under a different Notice/RFP (legible copies are acceptable) as long as it is on the same form as posted with this Synopsis. Offerors should follow up with clients/references to ensure timely submittal of questionnaires. If requested by the client, questionnaires may be submitted directly to the Government's point of contact, Network Contracting Office 2 Attn: Nicholas Winne via email at Nicholas.Winne@va.gov prior to the response date. Offerors shall not incorporate by reference into their response PPQs or CPARS previously submitted in response to other A/E services procurements. However, this does not preclude the Government from utilizing previously submitted PPQ information in the past performance evaluation. Criterion 5 - Capacity to accomplish the work in the required time. Firms/teams will be evaluated in terms of their ability to plan for and manage work under the contract and capacity to accomplish the work in the required time. Submission requirements: Describe the firm s ability to concurrently perform and manage multiple projects in different locations to meet aggressive schedules, multiple disciplines, and control costs and the firm s capacity as well as the sub consultants to accomplish multiple projects simultaneously. Contractor shall provide evidence of current work load and proposed team availability for this project. Provide a list of ongoing design project along with its percentage of completion. Criterion 6 - Location within a 400-mile radius to the design site (Canandaigua, NY) and knowledge of the location (Canandaigua, NY); provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project. Provided that the application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the contract, firms/teams will be evaluated on the locations of their office or offices that will be performing the work under this contract. Submission requirements: Indicate firms/teams location, including main offices, branch offices and any subconsultants offices and demonstrate how this will be advantageous to the Government. Criterion 7 - Subcontracting. The extent to which potential contractors identify and commit to the use of service-disabled Veteran-owned small businesses, Veteran-owned small businesses, and other types of small businesses as subcontractors. Submission requirements: Indicate sub-consultant firms socio-economic status on SF 330 Part I, Contract Specific Qualifications, Section C, Proposed Team. Evaluation Scoring Evaluation factors 1, 2, 3, 5, 6, and 7 will be evaluated using the following adjectival ratings as follows: Outstanding: Proposal meets requirements and indicates an exceptional approach and understanding of the requirements. Strengths far outweigh any weaknesses. Risk of unsuccessful performance is very low. Good: Proposal meets requirements and indicates a thorough approach and understanding of the requirements. Proposal contains strengths which outweigh any weaknesses. Risk of unsuccessful performance is low. Acceptable: Proposal meets requirements and indicates an adequate approach and understanding of the requirements. Strengths and weaknesses are offsetting or will have little or no impact on contract performance. Risk of unsuccessful performance is moderate. Marginal: Proposal does not clearly meet requirements and has not demonstrated an adequate approach and understanding of the requirements. The proposal has one or more weaknesses which are not offset by strengths. Risk of unsuccessful performance is high. Unacceptable: Proposal does not meet requirements and contains one or more deficiencies. Proposal is not awardable. The firm s proposal demonstrates a misunderstanding of the requirement, and the approach fails to meet performance standards. The firm s proposal has major omissions and inadequate details to assure evaluators that the offeror has an understanding of requirement. The ratings identified below were used in the evaluation of Past Performance (Criterion 4): Substantial Confidence: Based on the offeror s recent/relevant performance record, the Government has a high expectation that the offeror will successfully perform the required effort. No doubt exists based on the offeror s past performance that they can satisfy the requirements of the contract. Satisfactory Confidence: Based on the offeror s recent/relevant performance record, the Government has a reasonable expectation that the offeror will successfully perform the required effort. Little doubt exists based on the offeror s past performance that they could satisfy the requirements of the contract. Unknown Confidence (Neutral): No recent/relevant performance record is available, or the offeror s performance record is so sparse that no meaningful confidence assessment rating can be reasonably assigned. Limited Confidence: Based on the offeror s recent/relevant performance record, the Government has little expectation that the offeror will be able to successfully perform the required effort. Some doubt exists based on past performance that they could satisfy the terms and conditions of the contract. No Confidence: Based on the offeror s recent/relevant performance record, the Government has little expectations that the offeror will be able to successfully perform the required effort. Significant doubt exists based on the offeror s past performance that they can satisfy the requirements of the contract. SELECTION INTERVIEW: Interviews shall be scheduled with firms slated as the most highly qualified. Firms slated for interviews may be asked to explain or expand on information contained in the SF-330 submittal through a formal interview or a discussion questionnaire as determined by the Contracting Officer. GENERAL INFORMATION: All design and work will conform to the current edition of the VA Master Specifications and VA Design Standards as published at the following site: www.cfm.va.gov; ASME, OSHA, IBC 2009, NFPA and NEC building codes and standards. Coordinate all work through the COR of Facilities Management Service. Contractor is responsible for all cleanups and refuse disposal throughout the construction period. The A-E firm will prepare drawings and specifications in sufficient detail such that qualified outside General Contracting companies can prepare accurate and timely proposals for the desired construction work. Microsoft Project scheduling and management software will be used by both the A-E and Contractors to allow for regular tracking of schedules and work by the VA Medical Center. Schedules with MS Project will be regularly sent to the COR upon project initiation and whenever significant changes occur in the schedule. The estimated magnitude of construction is between $1,000,000 and $5,000,000 . The A-E will provide an initial estimate of cost to perform the above work and will design only those items that can be provided within the cost limitation. The Medical Center must remain operational throughout the construction period and a detailed sequence of work will be provided by the A-E to minimize impact of the construction. The A-E will provide documents at each submission as indicated in the statement of work. The NAICS code for this procurement will be 541330, Engineering Services. The current small business size standard for 541330 is $15 million. Requirement for Electronic Submission Unless paper offers are specifically authorized, all responses to this pre-solicitation notice must be submitted electronically as described below. The only acceptable paper form for this requirement is the receipt of past performance questionnaires. Failure to comply with this requirement may jeopardize the possibility of receiving an award for the contract due to non-compliance with the terms of the solicitation. You must submit your electronic offer, and any supplemental information (such as spreadsheets, backup data, technical information), using any of the electronic formats and media described below. In addition, contractors are notified of the award via an electronic Notice of Award e-mail. The award document will be attached to the Notice of Award e-mail. Acceptable Electronic Formats (Software) for Submission of Offers Files readable using the current Microsoft* Office version Products: Word, Excel, PowerPoint, or Access. Spreadsheet documents must be sent in a format that includes all formulas, macro, and format information. Print or scan images of spreadsheets are not acceptable. - Please see security note below for caution regarding use of macros. When submitting construction drawings contractors are required to submit one set in AutoCAD and one set in Adobe PDF. (Purpose: contracting can open the PDF version and engineering can open AutoCAD files) Files in Adobe* PDF (Portable Document Format) Files: When scanning documents scanner resolution should be set to 200 dots per inch, or greater. Other electronic format. - If you wish to submit an offer using another format than those described in these instructions, e-mail the Contracting Officer who issued the solicitation. Please submit your request at least ten (10) calendar days before the scheduled closing date of the solicitation. - Request a decision as to the format acceptability and make sure you receive approval of the alternate format before using it to send your offer. Please note that we can no longer accept .zip files due to increasing security concerns. E-mail Submission Procedures: For simplicity in this guidance, all submissions in response to a solicitation will be referred to as offers. Subject Line: Include the solicitation number, name of company, and closing date of solicitation. Use only one of the terms Quotation, Offer, or Bid depending on the solicitation type. Size: Maximum size of the e-mail message shall not exceed five (5) megabytes. The SF330, in its entirety, shall not exceed one email of 5MB. Only one email is permitted unless otherwise stated in this paragraph or in writing by the Contract Officer submitting the solicitation. The Microsoft Outlook © Email time/date stamp will be used to date and time stamp offers for the official record of receipt for the submission. The date and time stamp in recipients inbox is the official record of receipt. Security Issues, Late Bids, Unreadable Offers Late submission of offers are outlined at FAR Parts 52.212-1(f), 52.214-7, and 52.215-1(c)(3). Particular attention is warranted to the portion of the provision that relates to the timing of submission. - Please see FAR 15.207(c) for a description of the steps the Government shall take with regard to unreadable offers. - To avoid rejection of an offer, vendors must make every effort to ensure their electronic submission is virus-free. Submissions or portions thereof submitted and which the automatic system detects the presence of a virus or which are otherwise unreadable will be treated as unreadable pursuant to FAR Parts 14.406 and FAR 15.207(c ). The virus scanning software used by our e-mail systems cannot always distinguish a macro from a virus. Therefore, sending a macro embedded in an e-mail message or an e-mail attachment may cause the e-mail offer to be quarantined. You may send both the spreadsheet and the spreadsheet saved in PDF format to ensure that your proposal is readable. Password protecting your offer is not permitted. The Contracting Officer will file the offer electronically which will allow access only by designated individuals. Important Notice: Apparent successful offerors must apply for and receive verification from the Department of Veterans Affairs Center for Verification and Evaluation (CVE) in accordance with 38 CFR Part 74 and VAAR 819.70 by submission of documentation of Veteran status, ownership and control sufficient to establish appropriate status, offerors must be both VISIBLE and VERIFIED by the Department of Veterans Affairs Center for Verification and Evaluation prior to contract award. Failure to be both VERIFIED by CVE and VISIBLE on SBA prior to contract award will result in the offeror s proposal being deemed non-compliant. All offerors are urged to contact the CVE and submit the aforementioned required documents to obtain CVE verification of their SDVOSB status if they have not already done so.

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

NAICS: 238220
New
Federal
W045--Boiler Rental
Solicitation # 36C24227Q0042
The Department of Veterans Affairs, Network Contracting Office 02, is seeking a firm-fixed price contract for the temporary rental of a 1000 HP Fire tube Steam Boiler at the VA Hudson Valley Healthcare System Montrose Campus. The primary objective is to maintain N+1 compliance for the Building 20 Central Utilities Plant. The period of performance is scheduled from November 1, 2026, through March 31, 2027. The selected vendor will be responsible for the delivery, setup, integration into an existing 95 PSIG steam grid, ongoing maintenance, and eventual removal of the equipment. All work must adhere to VA regulations, the VHA Safety Device Testing Manual, and Boiler Plant Directive 1810. Amendment 0001 updated the solicitation by removing clauses 52.219-6 and 52.219-14 and scheduling a site visit for October 19, 2026, at 10:00 am at the Montrose Campus, Building 16 Engineering Conference Room. Quotes are due by October 21, 2026, and will be evaluated based on price, technical capability, and past performance, with the latter two combined being equal in weight to price. Offerors must provide a technical capability statement of no more than 10 pages, a certificate of liability insurance, and three relevant past performance references. The vendor is also required to provide two internal boiler inspection reports, one prior to delivery and one at the end of the rental period.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 24 hours ago

DEADLINE

in about 6 hours
View Details
NAICS: 621511
New
Federal
Q301--FY27 (BASE+4) STAT Laboratory Testing - Syracuse (VA-27-00010334)
Solicitation # 36C24227Q0069
The Department of Veterans Affairs VISN 2 Network Contracting Office intends to award a firm fixed-price contract for STAT laboratory testing services at the Syracuse VA Medical Center. The proposed contract structure includes a base period followed by four option periods. The government intends to sole source this requirement to University Pathologists Laboratories under FAR 6.302-1(a)(2), though this special notice serves as market research to identify other capable providers, including various small business socioeconomic categories. The scope of work involves the 24/7, 365-day-a-year analysis, monitoring, and reporting of clinical and surgical specimens, utilizing advanced methods such as electron microscopy and molecular studies. Key operational requirements include picking up specimens within 30 minutes of a request and delivering final written reports within five working days. Critical results require immediate notification to authorized providers. To be eligible, the contractor must employ board-certified pathologists and accredited technologists and maintain mandatory certifications, including a NYS Department of Health Clinical Laboratory Permit, a CLIA license, and CAP or Joint Commission accreditation. This acquisition falls under NAICS code 621511. Interested parties must provide documentation of their technical expertise and socioeconomic status to the contracting officer within 10 calendar days of the notice publication.
Medical Laboratories

POSTED

about 24 hours ago

DEADLINE

in 9 days
View Details
NAICS: 811210
New
Federal
J065--FY27 Q2 SERVICES (BASE+4) Globus NYH Service Contract (VA-27-00004429)
Solicitation # 36C24227Q0068
The Department of Veterans Affairs Network Contracting Office 2 intends to award a sole source contract to Globus Medical, Inc. for the annual preventative maintenance, corrective maintenance, and repair of proprietary Global Surgical Equipment. This includes the ExcelsiusGPS robotic system and ExcelsiusE3D system. The services will be performed at the VA New York Harbor Healthcare System's Manhattan and Brooklyn campuses. The base period of performance is scheduled from January 1, 2027, to December 31, 2027, with the possibility of four additional option years. The procurement falls under NAICS code 811210 for Electronic and Precision Equipment Repair and Maintenance, which has a small business size standard of 34 million dollars. It is noted that Globus Medical, Inc. has an exclusive authorized Service-Disabled Veteran Owned Small Business partner, SDV Office Systems, LLC, for sales of this equipment to federal government facilities. While this is a notice of intent for a sole source award, interested firms may submit written notification and supporting evidence of their ability to perform the requirements to Kaitlyn Morgan via email by October 27, 2026, at 12:00 p.m. EST. The government maintains sole discretion on whether to compete the procurement based on the responses received.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 24 hours ago

DEADLINE

in 6 days
View Details
NAICS: 541330
New
Federal
C1DA--NRM A/E- 528A7-27-112 Fire Alarm Panel Upgrade
Solicitation # 36C24227Q0070
The Department of Veterans Affairs, through Network Contracting Office 02, has issued a Request for Information to identify qualified Architect-Engineer firms for the upgrade of an obsolete Edwards EST-3 fire alarm system at the Syracuse VA Medical Center in New York. This is a sources sought notice and not a formal solicitation for proposals. The scope of work involves providing complete design and cost estimation services, including the upgrade of fire alarm control panels and remote annunciators, the installation of a new master control panel and fiber loop network, the expansion of the addressable system to additional campus buildings, and the removal of the existing fireman telephone system. The selected firm must also develop a phasing plan to ensure continuous fire alarm protection during construction and provide construction period services. A critical requirement for this project is that the prime firm must have a registered Fire Protection Engineer (FPE) on staff, and all drawings must be stamped by an FPE with no exceptions. All designs must comply with the latest editions of NFPA 70, NFPA 72, and the NEC, as well as applicable VA construction standards and fire protection design criteria. This opportunity falls under NAICS code 541330 for Engineering Services. Interested and capable sources must submit a written capability statement to the designated contract specialist by November 3, 2026, at 10:00 EST.
Engineering Services

POSTED

about 24 hours ago

DEADLINE

in 13 days
View Details
NAICS: 811210
New
Federal
J065--Philips Imaging Equipment preventative maintenance and repair services at the Northport VA Medical Center
Solicitation # 36C24227Q0066
The Department of Veterans Affairs Network Contracting Office 2 has issued a Notice of Intent to Sole Source for a full-service agreement to provide preventative maintenance and repair services for Philips imaging equipment at the Northport VA Medical Center. The intended awardee is Philips Healthcare, identified as the original equipment manufacturer and the sole authorized licenser of the required equipment and software. The period of performance is scheduled from February 1, 2027, to January 31, 2028. The scope of work includes the provision of authorized technicians, OEM parts, labor, tools, remote diagnostic support, and software updates for a specific inventory of equipment, including a Vereos PET/CT, two Ingenuity Core 128 CTs, two Veradius Mobile C-arms, and two EPIQ ultrasound systems. This procurement falls under NAICS code 811210 for Electronic and Precision Equipment Repair and Maintenance, with a size standard of 34 million dollars. While the government intends to sole source the contract, interested parties may submit capability documentation and technical backgrounds to demonstrate their ability to satisfy the requirements by October 28, 2026. All prospective contractors must be registered in the System for Award Management to be eligible for award. Responses must be submitted via email to the contract specialist, Lynn Krakowiak, using the specified subject line for the solicitation number 36C24227Q0066.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 24 hours ago

DEADLINE

in 7 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS