C1DA--657-23-101JB, FCA - Replace Various Air Handling Units in Buildings 1, 3, 24, 51 (VA-23-00012903)

Closed
36C25523Q0075Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

541330 - Engineering Services

Place of Performance

St Louis VAMC 1 Jefferson Barracks Dr, St. Louis, MO, 63125, USA

Set-Aside

SDVOSBC

Documents

1

36C25523Q0075.docx

DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)
Contacts1 person available
OfficeLEAVENWORTH, KS, 66048, USA
Office AddressLEAVENWORTH, KS, 66048, USA
Contacts
Jennifer SotomayorContract Specialist

Full Description

Show more
Sources Sought Notice Sources Sought Notice Page 3 of 5 Sources Sought Notice *= Required Field Sources Sought Notice DESCRIPTION Page 5 of 5 Title: 657-23-101JB Replace Various Air Handling Units in Buildings 1, 3, 24, 51 Solicitation Number: 36C25523Q0075 Agency: Department of Veterans Affairs Contracting Office: Network Contracting Office 15 Contracting Office Location: 3450 S 4th Street Trafficway, Leavenworth, KS. Type of Notice: Sources Sought Posted Date: 12/06/2022 Response Date: 12/12/2022 at 2:00 PM Central Time Set Aside: Service-Disabled Veteran Owned Small Business Classification Code: C211-Architect and Engineering- General: Landscaping, Interior Layout, and Designing NAICS Code: 541330 Engineering Services Synopsis: Please note that this is NOT a request for SF330's or proposals, the Government is seeking information for market research purposes only. The Government may or may not issue solicitation documents. The Department of Veterans Affairs Network Contracting Office (NCO) 15, is conducting a market survey for qualified: Service-Disabled Veteran Owned Small Businesses (SDVOSB), capable of providing the required services outlined below for the VA Medical Center located in Leavenworth, Kansas. The applicable NAICS code is 541330 Engineering Services and the size standard is $16.5 Million. Responses to this notice must be submitted via e-mail and received no later than December 12, 2022, at 2:00 PM Central Time. No telephone inquiries will be accepted or returned. Additional information about this project will be issued on the Federal Business Opportunities website https://www.fbo.gov once available. Prospective SDVOSB firms are reminded that in accordance with VA Acquisition Regulation (VAAR) 852.219-10, at least 50 percent of the cost of personnel for contract performance of the contract shall be spent for employees of the SDVOSB concern or employees of other eligible service-disabled veteran-owned small business concerns. The prime architect shall provide written certification of this to the Contracting Officer with the response provided for this market research. SCOPE OF DESIGN/CONSTRUCTION PROJECT: The intent of this project is to correct various Mechanical Equipment rated at D or F at the Jefferson Barracks Division, in buildings 1, 3, 24, and 51. This project will replace obsolete Air Handling Equipment, Ducts & Water Distribution Piping, Engineering Control System, Heating System Control Valves & Traps, Condensate Return Station, Fan Coil Units, and Ancillary Equipment which support buildings 1, 3, 24, and 51. The existing equipment is beyond its useful life cycle by approximately 11-45 years. The Facility Condition Assessment review identified the included mechanical equipment as being rated "D and F". By building and record number, the issues shown in attachment "657-23-101JB - FCA Report" will be addressed. Items listed below are priority items that need to be corrected. More items listed on the FCA Report will be included in the design, this will be dependent on the construction budget. Replacement of this mechanical equipment will also allow VASTLHCS to reduce energy consumption and green-house gas emission pursuant to Executive Orders 13423 and 13514. Finally, approval of this project will provide improved patient Environment of Care in regard to temperature and humidity control. We consider this to be critical infrastructure, fixing our usable/needed space, and therefore addresses one of the VHA Priorities for SCIP FY2023. The project includes, but is not limited to following scope: Building 1: (2) Trane Duplex AHUs serving 3rd Floor Offices & Corridors & (1) Trane Simplex AHU serving 3rd Floor (former Animal Research) are in need of replacement due to failed compressor units. Each unit is approximately 10 tons. The Morgue Refrigeration Unit is in need of replacement. (1) 2 HP duplex condensate pump and (2) 5 HP duplex condensate pumps serving the building need to be replaced. Remove and replace Vertical R-22 AHU located in the Old Pharmacy Area in Building 1, West Wing, Ground Level Room GW04. AHU leaks refrigerant. Building 3: The 60-ton reciprocating Carrier chiller is operating at 50% capacity due to leaking/damaged coils. The chiller provides chilled water to the FCU s. This chiller should be replaced. The 2 HP duplex condensate pump serving the building should be replaced. Building 24: The 1999 air handling unit (AHU-01), serving the Canteen and Auditorium is in poor condition due to multiple chilled water and steam coil leaks . These coils have been cut and fused closed. This units need to be replaced. This unit provides approximately (20) tons of cooling. There is an old exhaust fan (1.5 HP) in the crawl space of the mechanical room that needs to be replaced. Building 51: AHU in B-105, serving the North side of the 1st Floor, is in poor condition and should be replaced. All of the FCU s are reported to operate with hot water now, instead of steam. The 1st Floor FCU s have been replaced, though the remaining FCU s (approx. 130 units) need to be replaced. The 22 VAV boxes have hot water reheat coils that are in need of replacement. Both pumps are for hot water distribution. (1) pump has been replaced and is relatively new (good condition). (1) pump is old and is in need of replacement. Both pumps are 1 HP each. There are (2) steam to hot water converters that are in need of replacement, as they re both at the end of their useful life. The VA recommends that these heat exchangers be replaced. 33 GPM @ 35' HX(2) Part# 5-260-08-072-002. Anticipated time for completion of design is 175 calendar days including time for VA reviews. In accordance with VAAR 836.204, the estimated magnitude of the resulting construction price range is estimated to be Between $5,000,000 and $10,000,000. The North American Industrial Classification System (NAICS) code is 541330, Engineering Services, small business size standard of $16.5 Million in average annual receipts for the preceding three years. Interested firms must be registered in https: www.SAM.gov with this NAICS code and qualified as a service-disabled veteran owned small business under this NAICS code. Qualified service-disabled veteran owned small businesses are encouraged to respond and required to be registered in the VetBiz registry https://www.vetbiz.va.gov/ on or before the response date. The response to this notice shall be in summary format and shall not exceed ten (10) total pages and include the following: Company name, DUNS number, verification of social economic category (SDVOSB), address, point of contact, telephone number and email address, sample information on same or similar type projects completed. No basis for claim against the Government shall arise because of a response to this source sought or Government use of any information provided. The Government will not pay for information or comments provided and will not recognize any costs associated with submission of comments. There is no guarantee, expressed or implicit, that market research for this acquisition will result in a particular set-aside, or any other guarantee of award or acquisition strategy. Responses must be received by 2:00 PM Central on December 12, 2022, via e-mail to the Contracting Officer at contact@example.gov. PLEASE REFERENCE "SOURCES SOUGHT: Project 657-23-101JB Replace Various Air Handling Units in Buildings 1, 3, 24, 51." IN THE SUBJECT LINE and cover sheet. Respondents will not be contacted regarding their submission or information gathered because of this Sources Sought notice. Interested firms shall be required to respond to additional announcements separately from this announcement without further notice from the Government when posted to the Contract Opportunities website at https://sam.gov/. The Contract Opportunities website is the only official site to obtain these documents. Contracting Office Address: Department of Veterans Affairs Network 15 Contracting Office; 3450 S. 4th Street, Leavenworth, KS 66048. Point of Contact(s): Jennifer.Sotomayor Contracting Officer e-mail address: contact@example.gov

More opportunities from Department Of Veterans Affairs → 255-NETWORK Contract Office 15 (36C255)

Same awarding agency

NAICS: 236220
New
Federal
Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB
Solicitation # 36C25527Q0044
The Department of Veterans Affairs, Network Contracting Office 15, is conducting market research through a Sources Sought Notice to determine the availability of qualified Service-Disabled Veteran-Owned Small Business (SDVOSB) firms for a construction project at the St. Louis Medical Center Jefferson Barracks. The project involves the replacement of the roof and associated components for Building 51, covering approximately 56,000 square feet. The scope includes installing a 70-mil thermoplastic polyolefin (TPO) roofing system, replacing four skylights, and updating the penthouse roof-access ladder to meet OSHA and VA safety standards. The estimated value of the resulting contract is between 2 million and 5 million dollars, with a required performance period of 222 calendar days from the Notice to Proceed. The project requires the contractor to manage work within an occupied 24/7 facility, necessitating a detailed phasing plan and strict adherence to infection control and HVAC-intake protection. Key technical requirements include providing a 20-year no-dollar-limit warranty, ensuring positive drainage to prevent standing water for more than 48 hours, and submitting as-built record drawings in searchable PDF and editable CAD formats. Interested firms must be registered in SAM.gov under NAICS code 236220 and provide a capability statement by November 9, 2026, including evidence of CVE certification, bonding capability, and a history of comparable work performed within the last five years.
Commercial and Institutional Building Construction

POSTED

about 12 hours ago

DEADLINE

in 11 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS